Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns.

Stefan Bayer1, Dominik Kraus, Ludger Keilig, Lina Gölz, Helmut Stark, Norbert Enkling.   

Abstract

PURPOSE: The aim of this study was to examine the wear behavior of conical crowns with electroplated gold copings that are used to connect implants and teeth to a removable denture. Gold alloy and zirconium dioxide ceramic crowns were compared.
MATERIALS AND METHODS: Fifteen crowns each were milled for two groups: gold alloy and zirconium dioxide. Each specimen had a 2-degree taper. The electroplated coping was established by direct electroforming. The retentive forces and the correlating distance during insertion and separation were measured after 10,000 wear cycles were applied. The wear testing was separated into a start phase, an initial wear phase, and the long-term wear period. The retention force value and the force-distance integral of the first 0.3 mm of each cycle were calculated.
RESULTS: The changes in retention force and integral did not differ significantly between both groups in the start and the initial wear phase. No differences were seen in force development during the long-term wear period. Only the force-distance integral showed a significant difference: the median values of the gold crowns increased slightly, and they decreased slightly for the zirconia crowns. The median force values never fell below 6 N for gold and 4 N for zirconia.
CONCLUSIONS: Within the limitations of this study, the tested conical crowns showed clinically acceptable retentive properties. As with other retentive elements for dentures, the specimens tested showed the greatest amount of change in retentive forces during the first 2,000 cycles. The development of retention force in both groups was not significantly different. However, the zirconia specimens showed reduced variability, which is preferable in clinical practice.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22616051

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

2.  Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes.

Authors:  Franz Sebastian Schwindling; Ulrich Karl Deisenhofer; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

3.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

4.  Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns.

Authors:  Sven Rinke; Ralf Buergers; Dirk Ziebolz; Matthias Roediger
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

5.  Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations.

Authors:  Martin Schimmel; Moritz Walther; Nadin Al-Haj Husain; Kensuke Igarashi; Julia Wittneben; Samir Abou-Ayash
Journal:  Clin Oral Investig       Date:  2021-04-08       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.