Literature DB >> 22595696

The effect of pneumatic tube system on complete blood count parameters and thrombocyte donation in healthy donors.

Ismail Sari1, Aliriza Arslan, Can Ozlu, Sibel Hacioglu, Mehmet Hilmi Dogu, Kamil Isler, Ali Keskin.   

Abstract

This paper is the first report whether or not pneumatic tube system affects the selection of apheresis donors according to the results of complete blood count. According to the apheresis guidelines, hemoglobin level must be ≥12.5g/dL and platelet level ≥150/μL to be a donor. Paired blood samples of 26 healthy volunteers were transported by either hand delivered or a pneumatic tube system to the laboratory. No statistically significant differences were observed in order to mean values of routine complete blood cell count and white cell differential parameters that were send for selection of apheresis donor before the procedure. Therefore, all healthy volunteers decided as a donor according to the laboratory results independent from transport method.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22595696     DOI: 10.1016/j.transci.2012.05.005

Source DB:  PubMed          Journal:  Transfus Apher Sci        ISSN: 1473-0502            Impact factor:   1.764


  2 in total

1.  The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests.

Authors:  Fatma Emel Koçak; Mustafa Yöntem; Ozlem Yücel; Mustafa Cilo; Ozlem Genç; Ayfer Meral
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

2.  Assessing Safety of Pneumatic Tube System (PTS) for Patients with Very Low Hematologic Parameters.

Authors:  Mustafa Koroglu; Mehmet Ali Erkurt; Irfan Kuku; Emin Kaya; Ilhami Berber; Ilknur Nizam; Yavuz Yagar; Seyit Ali Kayis
Journal:  Med Sci Monit       Date:  2016-04-20
  2 in total