Literature DB >> 22583195

How should we investigate breast implant rupture?

Phoebe M Hold1, Shabana Alam, William J Pilbrow, Judith F Kelly, Elizabeth M Everitt, Sanjiv K Dhital, Ali Juma.   

Abstract

We aimed to examine a cohort of patients presenting with breast implant complications to establish the sensitivity and specificity of clinical examination, Ultrasound Scanning (US) and Magnetic Resonance Imaging (MRI) in the diagnosis of implant rupture, and to examine the correlation between US and MRI. We performed a 26-month retrospective review. Patients underwent US and MRI to exclude rupture. Results of US and MRI were compared prospectively for concordance, then retrospectively to clinical findings and surgical diagnosis. Thirty-four patients with 60 implants were reviewed. The sensitivities of clinical diagnosis, US, and MRI for rupture was 42%, 50%, and 83%, respectively, while the specificities were 50%, 90%, and 90%. The concordance between US and MRI was 87%. MRI is the investigation of choice for implant rupture. US is a valuable alternative with good concordance with MRI. When US is positive for implant rupture an MRI is not necessary to confirm the diagnosis. Knowledge of the sensitivity and specificity as well as the concordance between the two investigations is useful to ensure the appropriate use of available resources.
© 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22583195     DOI: 10.1111/j.1524-4741.2012.01226.x

Source DB:  PubMed          Journal:  Breast J        ISSN: 1075-122X            Impact factor:   2.431


  8 in total

1.  Breast cancer following polyacrylamide hydrogel injection for breast augmentation: A case report.

Authors:  Gang Chen; Yujia Wang; Jin-Long Huang
Journal:  Mol Clin Oncol       Date:  2016-01-14

Review 2.  Breast MRI: EUSOBI recommendations for women's information.

Authors:  Ritse M Mann; Corinne Balleyguier; Pascal A Baltzer; Ulrich Bick; Catherine Colin; Eleanor Cornford; Andrew Evans; Eva Fallenberg; Gabor Forrai; Michael H Fuchsjäger; Fiona J Gilbert; Thomas H Helbich; Sylvia H Heywang-Köbrunner; Julia Camps-Herrero; Christiane K Kuhl; Laura Martincich; Federica Pediconi; Pietro Panizza; Luis J Pina; Ruud M Pijnappel; Katja Pinker-Domenig; Per Skaane; Francesco Sardanelli
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

3.  Breast ultrasound: recommendations for information to women and referring physicians by the European Society of Breast Imaging.

Authors:  Andrew Evans; Rubina M Trimboli; Alexandra Athanasiou; Corinne Balleyguier; Pascal A Baltzer; Ulrich Bick; Julia Camps Herrero; Paola Clauser; Catherine Colin; Eleanor Cornford; Eva M Fallenberg; Michael H Fuchsjaeger; Fiona J Gilbert; Thomas H Helbich; Karen Kinkel; Sylvia H Heywang-Köbrunner; Christiane K Kuhl; Ritse M Mann; Laura Martincich; Pietro Panizza; Federica Pediconi; Ruud M Pijnappel; Katja Pinker; Sophia Zackrisson; Gabor Forrai; Francesco Sardanelli
Journal:  Insights Imaging       Date:  2018-08-09

4.  Poly implant breast implants (PIP) and the rupture risk in asymptomatic patients: a warning for greater clinician suspicion in assessment and counselling.

Authors:  Senthurun Mylvaganam; Rebecca Taylor; Steven Thrush
Journal:  J Surg Case Rep       Date:  2013-02-06

5.  A 10-Year Prospective Study of Implant-Based Breast Augmentation and Reconstruction.

Authors:  Robert El-Haddad; Béatrice Lafarge-Claoue; Charles Garabedian; Sylvain Staub
Journal:  Eplasty       Date:  2018-02-08

Review 6.  Plastic Surgery Complications: A Review for Emergency Clinicians.

Authors:  Tim Montrief; Kasha Bornstein; Mark Ramzy; Alex Koyfman; Brit J Long
Journal:  West J Emerg Med       Date:  2020-09-25

7.  The Value of Ultrasound in the Evaluation of the Integrity of Silicone Breast Implants.

Authors:  Dalia Rukanskienė; Greta Bytautaitė; Agnė Česnauskaitė; Loreta Pilipaitytė; Tautrimas Aštrauskas; Eglė Jonaitienė
Journal:  Medicina (Kaunas)       Date:  2021-05-03       Impact factor: 2.430

8.  Diagnostic value of a spiral breast computed tomography system equipped with photon counting detector technology in patients with implants: An observational study of our initial experiences.

Authors:  Lisa Ruby; Sojin Shim; Nicole Berger; Magda Marcon; Thomas Frauenfelder; Andreas Boss
Journal:  Medicine (Baltimore)       Date:  2020-07-24       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.