Literature DB >> 22580790

Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid.

Shabnam Shahida1, Akbar Ali, Muhammad Haleem Khan, Muhammad Mufazzal Saeed.   

Abstract

In this work, spectrophotometer was used as a detector for the determination of uranium from water, biological, and ore samples with a flow injection system coupled with solid phase extraction. In order to promote the online preconcentration of uranium, a minicolumn packed with XAD-4 resin impregnated with nalidixic acid was utilized. The system operation was based on U(VI) ion retention at pH 6 in the minicolumn at flow rate of 15.2 mL min(-1). The uranium complex was removed from the resin by 0.1 mol dm(-3) HCl at flow rate of 3.2 mL min(-1) and was mixed with arsenazo III solution (0.05 % solution in 0.1 mol dm(-3) HCl, 3.2 mL min(-1)) and driven to flow through cell of spectrophotometer where its absorbance was measured at 651 nm. The influence of chemical (pH and HCl (as eluent and reagent medium) concentration) and flow (sample and eluent flow rate and preconcentration time) parameters that could affect the performance of the system as well as the possible interferents was investigated. At the optimum conditions for 60 s preconcentration time (15.2 mL of sample volume), the method presented a detection limit of 1.1 μg L(-1), a relative standard deviation (RSD) of 0.8 % at 100 μg L(-1), enrichment factor of 30, and a sample throughput of 42 h(-1), whereas for 300 s of the preconcentration time (76 mL of sample volume), a detection limit of 0.22 μg L(-1), a RSD of 1.32 % at 10 μg L(-1), enrichment factor of 150, and a sampling frequency of 11 h(-1) were reported.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22580790     DOI: 10.1007/s10661-012-2655-4

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  14 in total

Review 1.  Review of recent applications of flow injection spectrophotometry to pharmaceutical analysis.

Authors:  Paraskevas D Tzanavaras; Demetrius G Themelis
Journal:  Anal Chim Acta       Date:  2007-01-30       Impact factor: 6.558

2.  An online preconcentration system for the determination of uranium in water and effluent samples.

Authors:  Valfredo Azevedo Lemos; Ednilton Moreira Gama
Journal:  Environ Monit Assess       Date:  2009-12-16       Impact factor: 2.513

3.  Spectrophotometric determination of uranium with arsenazo-III in perchloric acid.

Authors:  Muhammad Haleem Khan; Peter Warwick; Nick Evans
Journal:  Chemosphere       Date:  2005-11-16       Impact factor: 7.086

4.  Simultaneous spectrophotometric determination of uranium and thorium by flow injection analysis using selective masking.

Authors:  Yoshihiro Hirano; Yuichi Ogawa; Koichi Oguma
Journal:  Anal Sci       Date:  2003-02       Impact factor: 2.081

5.  Determination of copper in biological samples by flame atomic absorption spectrometry after precipitation with Me-BTAP.

Authors:  Valfredo A Lemos; Geisiane dos S Novaes; Anaildes L de Carvalho; Ednilton M Gama; Aldenor G Santos
Journal:  Environ Monit Assess       Date:  2008-01-31       Impact factor: 2.513

6.  Solid phase extraction of Cu(II), Ni(II), Pb(II), Cd(II) and Mn(II) ions with 1-(2-thiazolylazo)-2-naphthol loaded Amberlite XAD-1180.

Authors:  Serife Tokalioğlu; Vedat Yilmaz; Senol Kartal
Journal:  Environ Monit Assess       Date:  2008-05-17       Impact factor: 2.513

7.  Solid phase extractive preconcentration of silver from aqueous samples.

Authors:  Sevda Ayata; Ipek Kaynak; Melek Merdivan
Journal:  Environ Monit Assess       Date:  2008-05-29       Impact factor: 2.513

8.  Factorial design in the optimization of preconcentration procedure for lead determination by FAAS.

Authors:  Mustafa Soylak; Ibrahim Narin; Marcos de Almeida Bezerra; Sérgio Luís Costa Ferreira
Journal:  Talanta       Date:  2005-02-28       Impact factor: 6.057

9.  Protonation equilibria of quinolone antibacterials in acetonitrile-water mobile phases used in LC.

Authors:  J Barbosa; R Bergés; I Toro; V Sanz-Nebot
Journal:  Talanta       Date:  1997-07       Impact factor: 6.057

10.  Amberlite XAD-4 functionalized with succinic acid for the solid phase extractive preconcentration and separation of uranium(VI).

Authors:  P Metilda; K Sanghamitra; J Mary Gladis; G R K Naidu; T Prasada Rao
Journal:  Talanta       Date:  2005-01-15       Impact factor: 6.057

View more
  1 in total

1.  Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid.

Authors:  Shabnam Shahida; Akbar Ali; Muhammad Haleem Khan; Muhammad Mufazzal Saeed
Journal:  Environ Monit Assess       Date:  2012-05-13       Impact factor: 2.513

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.