Causes of failure of neonatal patient triggered ventilation.

M F Hird1, A Greenough.   

Abstract

Causes of failure of patient triggered ventilation (PTV) in neonates have been determined. In particular we have investigated the importance of the timing of ventilator inflation in the spontaneous respiratory cycle and hence the respiratory interaction provoked during PTV. Fifty-six infants (median gestational age 29 weeks) were studied on 63 occasions using two different trigger systems, changes in airway pressure and airflow. After one hour of PTV, only 26 infants were synchronous (inflation coinciding with and occurring only in inspiration), 8 were apnoeic. In the remaining 29 infants, inflation extended into expiration, five of whom were actively expiring. The timing of inflation in the spontaneous respiratory cycle and the interaction provoked was significantly related to the trigger delay, but not the inflation time or type of trigger used. Oxygenation after one hour of PTV improved in infants in whom inflation occurred in inspiration only and in some when it extended beyond. Failure of long term PTV was more common, however, in infants in whom inflation extended beyond inspiration (i.e. asynchronous), but this did not relate to the type of trigger used. Failure was also associated with a long trigger delay (P less than 0.01), a very short inflation time (P less than 0.01) and commencement of PTV early in the infant's illness (P less than 0.05). We conclude that synchrony is the most beneficial respiratory interaction during PTV. Our data suggest that this interaction would be more consistently provoked by the use of a sensitive triggering system which ensured a short trigger delay.

Entities:  

Mesh:

Year:  1990        PMID: 2257787     DOI: 10.1016/0378-3782(90)90133-4

Source DB:  PubMed          Journal:  Early Hum Dev        ISSN: 0378-3782            Impact factor:   2.079


  7 in total

1.  Accuracy of volume measurements in mechanically ventilated newborns: a comparative study of commercial devices.

Authors:  K Roske; B Foitzik; R R Wauer; G Schmalisch
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

2.  Long term trigger ventilation in neonatal respiratory distress syndrome.

Authors:  R C de Boer; A Jones; P S Ward; J H Baumer
Journal:  Arch Dis Child       Date:  1993-03       Impact factor: 3.791

3.  Patient triggered ventilation using a flow triggered system.

Authors:  M F Hird; A Greenough
Journal:  Arch Dis Child       Date:  1991-10       Impact factor: 3.791

4.  Evaluation of triggering systems for patient triggered ventilation for neonates ventilator-dependent beyond 10 days of age.

Authors:  V Chan; A Greenough
Journal:  Eur J Pediatr       Date:  1992-11       Impact factor: 3.183

5.  Patient triggered ventilation in chronically ventilator-dependent infants.

Authors:  M F Hird; A Greenough
Journal:  Eur J Pediatr       Date:  1991-08       Impact factor: 3.183

6.  Randomised controlled trial of weaning by patient triggered ventilation or conventional ventilation.

Authors:  V Chan; A Greenough
Journal:  Eur J Pediatr       Date:  1993-01       Impact factor: 3.183

Review 7.  Synchronized mechanical ventilation for respiratory support in newborn infants.

Authors:  Anne Greenough; Thomas E Rossor; Adesh Sundaresan; Vadivelam Murthy; Anthony D Milner
Journal:  Cochrane Database Syst Rev       Date:  2016-09-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.