Literature DB >> 22576352

Oscillating and pulsed gradient diffusion magnetic resonance microscopy over an extended b-value range: implications for the characterization of tissue microstructure.

S Portnoy1, J J Flint, S J Blackband, G J Stanisz.   

Abstract

Oscillating gradient spin-echo (OGSE) pulse sequences have been proposed for acquiring diffusion data with very short diffusion times, which probe tissue structure at the subcellular scale. OGSE sequences are an alternative to pulsed gradient spin echo measurements, which typically probe longer diffusion times due to gradient limitations. In this investigation, a high-strength (6600 G/cm) gradient designed for small-sample microscopy was used to acquire OGSE and pulsed gradient spin echo data in a rat hippocampal specimen at microscopic resolution. Measurements covered a broad range of diffusion times (TDeff = 1.2-15.0 ms), frequencies (ω = 67-1000 Hz), and b-values (b = 0-3.2 ms/μm2). Variations in apparent diffusion coefficient with frequency and diffusion time provided microstructural information at a scale much smaller than the imaging resolution. For a more direct comparison of the techniques, OGSE and pulsed gradient spin echo data were acquired with similar effective diffusion times. Measurements with similar TDeff were consistent at low b-value (b < 1 ms/μm(2) ), but diverged at higher b-values. Experimental observations suggest that the effective diffusion time can be helpful in the interpretation of low b-value OGSE data. However, caution is required at higher b, where enhanced sensitivity to restriction and exchange render the effective diffusion time an unsuitable representation. Oscillating and pulsed gradient diffusion techniques offer unique, complementary information. In combination, the two methods provide a powerful tool for characterizing complex diffusion within biological tissues.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22576352      PMCID: PMC3421060          DOI: 10.1002/mrm.24325

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Measurements of restricted diffusion using an oscillating gradient spin-echo sequence.

Authors:  M Schachter; M D Does; A W Anderson; J C Gore
Journal:  J Magn Reson       Date:  2000-12       Impact factor: 2.229

Review 2.  The basis of anisotropic water diffusion in the nervous system - a technical review.

Authors:  Christian Beaulieu
Journal:  NMR Biomed       Date:  2002 Nov-Dec       Impact factor: 4.044

3.  Planar microcoil-based microfluidic NMR probes.

Authors:  C Massin; F Vincent; A Homsy; K Ehrmann; G Boero; P-A Besse; A Daridon; E Verpoorte; N F de Rooij; R S Popovic
Journal:  J Magn Reson       Date:  2003-10       Impact factor: 2.229

4.  Effects of barrier-induced nuclear spin magnetization inhomogeneities on diffusion-attenuated MR signal.

Authors:  A L Sukstanskii; J J H Ackerman; D A Yablonskiy
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

5.  Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain.

Authors:  Mark D Does; Edward C Parsons; John C Gore
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

6.  Diffusion heterogeneity and anisotropy in rat hippocampus.

Authors:  T Mazel; Z Simonová; E Syková
Journal:  Neuroreport       Date:  1998-05-11       Impact factor: 1.837

7.  Statistical assessment of non-Gaussian diffusion models.

Authors:  Anders Kristoffersen
Journal:  Magn Reson Med       Date:  2011-04-26       Impact factor: 4.668

8.  An analytical model of restricted diffusion in bovine optic nerve.

Authors:  G J Stanisz; A Szafer; G A Wright; R M Henkelman
Journal:  Magn Reson Med       Date:  1997-01       Impact factor: 4.668

9.  Measurement of signal intensities in the presence of noise in MR images.

Authors:  R M Henkelman
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

10.  Analysis of dendritic spines in rat CA1 pyramidal cells intracellularly filled with a fluorescent dye.

Authors:  M Trommald; V Jensen; P Andersen
Journal:  J Comp Neurol       Date:  1995-03-06       Impact factor: 3.215

View more
  29 in total

1.  Mesoscopic structure of neuronal tracts from time-dependent diffusion.

Authors:  Lauren M Burcaw; Els Fieremans; Dmitry S Novikov
Journal:  Neuroimage       Date:  2015-03-30       Impact factor: 6.556

2.  Imaging neurodegeneration in the mouse hippocampus after neonatal hypoxia-ischemia using oscillating gradient diffusion MRI.

Authors:  Manisha Aggarwal; Jennifer Burnsed; Lee J Martin; Frances J Northington; Jiangyang Zhang
Journal:  Magn Reson Med       Date:  2013-10-04       Impact factor: 4.668

3.  Inferring diameters of spheres and cylinders using interstitial water.

Authors:  Sheryl L Herrera; Morgan E Mercredi; Richard Buist; Melanie Martin
Journal:  MAGMA       Date:  2018-06-04       Impact factor: 2.310

4.  Diffusion-time dependence of diffusional kurtosis in the mouse brain.

Authors:  Manisha Aggarwal; Matthew D Smith; Peter A Calabresi
Journal:  Magn Reson Med       Date:  2020-02-05       Impact factor: 4.668

5.  The Effect of Microcirculatory Flow on Oscillating Gradient Diffusion MRI and Diffusion Encoding with Dual-Frequency Orthogonal Gradients (DEFOG).

Authors:  Dan Wu; Jiangyang Zhang
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

6.  Diffusion time dependence of microstructural parameters in fixed spinal cord.

Authors:  Sune Nørhøj Jespersen; Jonas Lynge Olesen; Brian Hansen; Noam Shemesh
Journal:  Neuroimage       Date:  2017-08-14       Impact factor: 6.556

7.  Reduced visualization of cerebral infarction on diffusion-weighted images with short diffusion times.

Authors:  Arunnit Boonrod; Akifumi Hagiwara; Masaaki Hori; Issei Fukunaga; Christina Andica; Tomoko Maekawa; Shigeki Aoki
Journal:  Neuroradiology       Date:  2018-07-26       Impact factor: 2.804

Review 8.  Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation.

Authors:  Dmitry S Novikov; Els Fieremans; Sune N Jespersen; Valerij G Kiselev
Journal:  NMR Biomed       Date:  2018-10-15       Impact factor: 4.044

9.  Fast and robust measurement of microstructural dimensions using temporal diffusion spectroscopy.

Authors:  Hua Li; John C Gore; Junzhong Xu
Journal:  J Magn Reson       Date:  2014-02-19       Impact factor: 2.229

10.  Pulsed and oscillating gradient MRI for assessment of cell size and extracellular space (POMACE) in mouse gliomas.

Authors:  Olivier Reynaud; Kerryanne Veronica Winters; Dung Minh Hoang; Youssef Zaim Wadghiri; Dmitry S Novikov; Sungheon Gene Kim
Journal:  NMR Biomed       Date:  2016-07-22       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.