Literature DB >> 22575286

Impact of alcohol-impregnated port protectors and needleless neutral pressure connectors on central line-associated bloodstream infections and contamination of blood cultures in an inpatient oncology unit.

Michael A Sweet1, Aaron Cumpston, Frank Briggs, Michael Craig, Mehdi Hamadani.   

Abstract

BACKGROUND: A major risk factor for the development of bloodstream infection is the presence of a central venous catheter (CVC), especially in immunocompromised patients. CVC hub contamination is a risk factor for central line-associated bloodstream infection (CLABSI).
METHODS: This observational before-after trial in a tertiary care hospital's oncology unit included adult patients with a CVC. During the intervention period, the practice of central line hub care was changed from cleaning with alcohol wipes to using alcohol-impregnated port protectors. To accommodate the protectors, the needless hubs were changed to a neutral pressure connector. The intervention period (January-July 2010) was compared with a historical control (January-December 2009).
RESULTS: A total of 3,005 central line-days and 1 CLABSI (a rate of 0.3 infections/1,000 central line-days) were documented during the intervention period, compared with 6,851 central line-days and 16 CLABSIs (2.3 infections/1,000 central line-days) during the control period (relative risk, 0.14; 95% confidence interval [CI], 0.02-1.07; P = .03). The rate of contaminated blood cultures (CBCs) from central lines was 2.5% (17 of 692) during the control period, but only 0.2% (1 of 470) during the intervention period (relative risk, 0.09; 95% CI, 0.01-0.65; P = .002).
CONCLUSIONS: The implementation of alcohol-impregnated port protectors and needleless neutral pressure connectors significantly reduced the rates of CLABSIs and CBCs in our oncology patient population.
Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22575286     DOI: 10.1016/j.ajic.2012.01.025

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  15 in total

1.  Use of Disinfection Cap to Reduce Central-Line-Associated Bloodstream Infection and Blood Culture Contamination Among Hematology-Oncology Patients.

Authors:  Mini Kamboj; Rachel Blair; Natalie Bell; Crystal Son; Yao-Ting Huang; Mary Dowling; Allison Lipitz-Snyderman; Janet Eagan; Kent Sepkowitz
Journal:  Infect Control Hosp Epidemiol       Date:  2015-09-23       Impact factor: 3.254

2.  Needleless connectors: the vascular access catheter's microbial gatekeeper.

Authors:  Evonne Curran
Journal:  J Infect Prev       Date:  2016-07-25

Review 3.  Prevention of Central Line-Associated Bloodstream Infections.

Authors:  Taison Bell; Naomi P O'Grady
Journal:  Infect Dis Clin North Am       Date:  2017-07-05       Impact factor: 5.982

4.  Reduction of central line-associated bloodstream infections in a large acute care hospital in Midwest United States following implementation of a comprehensive central line insertion and maintenance bundle.

Authors:  Abraham E Wei; Ronald J Markert; Christopher Connelly; Hari Polenakovik
Journal:  J Infect Prev       Date:  2021-06-22

Review 5.  Curos™ Disinfection Caps for the Prevention of Infection When Using Needleless Connectors: A NICE Medical Technologies Guidance.

Authors:  Susan O'Connell; Megan Dale; Helen Morgan; Kimberley Carter; Grace Carolan-Rees
Journal:  Appl Health Econ Health Policy       Date:  2021-03       Impact factor: 2.561

6.  Cluster-Randomized Trial of Devices to Prevent Catheter-Related Bloodstream Infection.

Authors:  Steven M Brunelli; David B Van Wyck; Levi Njord; Robert J Ziebol; Laurie E Lynch; Douglas P Killion
Journal:  J Am Soc Nephrol       Date:  2018-02-22       Impact factor: 10.121

7.  Alcohol-impregnated caps and ambulatory central-line-associated bloodstream infections (CLABSIs): A randomized clinical trial.

Authors:  Aaron M Milstone; Carol Rosenberg; Gayane Yenokyan; Danielle W Koontz; Marlene R Miller
Journal:  Infect Control Hosp Epidemiol       Date:  2020-10-12       Impact factor: 3.254

Review 8.  Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review.

Authors:  Nancy L Moureau; Julie Flynn
Journal:  Nurs Res Pract       Date:  2015-05-14

Review 9.  APSIC guide for prevention of Central Line Associated Bloodstream Infections (CLABSI).

Authors:  Moi Lin Ling; Anucha Apisarnthanarak; Namita Jaggi; Glenys Harrington; Keita Morikane; Le Thi Anh Thu; Patricia Ching; Victoria Villanueva; Zhiyong Zong; Jae Sim Jeong; Chun-Ming Lee
Journal:  Antimicrob Resist Infect Control       Date:  2016-05-04       Impact factor: 4.887

Review 10.  Prevention of Device-Related Healthcare-Associated Infections.

Authors:  Edward J Septimus; Julia Moody
Journal:  F1000Res       Date:  2016-01-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.