Literature DB >> 22565882

Short implant to support maxillary restorations: bone stress analysis using regular and switching platform.

Nivaldo Antônio de Carvalho1, Erika Oliveira de Almeida, Eduardo Passos Rocha, Amílcar Chagas Freitas, Rodolfo Bruniera Anchieta, Sidney Kina.   

Abstract

PURPOSE: The aim of this study was to evaluate stress distribution on peri-implant bone simulating the influence of implants with different lengths on regular and switching platforms in the anterior maxilla by means of three-dimensional finite element analysis.
MATERIALS AND METHODS: Four mathematical models of a central incisor supported by an external hexagon implant (diameter, 5.0 mm) were created, varying the length (15.0 mm for long implants [L] and 7.0 mm for short implants [S]) and the diameter of the abutment platform (5.0 mm for regular models [R] and 4.1 mm for switching models [S]). The models were created using the Mimics 11.11 (Materialise) and SolidWorks 2010 (Inovart) software. Numerical analysis was performed using ANSYS Workbench 10.0 (Swanson Analysis System). Oblique forces (100 N) were applied to the palatine surface of the central incisor. The bone/implant interface was considered perfectly integrated. Maximum (σ(max)) and minimum (σ(min)) principal stress values were obtained.
RESULTS: For the cortical bone, the highest stress values (σ(max)) were observed in the SR (73.7 MPa) followed by LR (65.1 MPa), SS (63.6 MPa), and LS (54.2 MPa). For the trabecular bone, the highest stress values (σ(max)) were observed in the SS (8.87 MPa) followed by the SR (8.32 MPa), LR (7.49 MPa), and LS (7.08 MPa).
CONCLUSIONS: The influence of switching platform was more evident for the cortical bone in comparison with the trabecular bone for the short and long implants. The long implants showed lower stress values in comparison to the short implants, mainly when the switching platform was used.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22565882     DOI: 10.1097/SCS.0b013e31824dbab7

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  3 in total

1.  Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads.

Authors:  Ángel Álvarez-Arenal; Luis Segura-Mori; Ignacio Gonzalez-Gonzalez; Hector DeLlanos-Lanchares; Fernando Sanchez-Lasheras; Joseba Ellacuria-Echevarria
Journal:  Odontology       Date:  2016-03-04       Impact factor: 2.634

2.  Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis.

Authors:  Sergio Alexandre Gehrke; Victor Lourenço Frugis; Jamil Awad Shibli; Maria Piedad Ramirez Fernandez; José Eduardo Maté Sánchez de Val; José Luis Calvo Girardo; Silvio Taschieri; Stefano Corbella
Journal:  Open Dent J       Date:  2016-09-30

Review 3.  Application of Finite Element Model in Implant Dentistry: A Systematic Review.

Authors:  M Sesha Reddy; Rajasekar Sundram; Hossam Abdelatty Eid Abdemagyd
Journal:  J Pharm Bioallied Sci       Date:  2019-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.