Literature DB >> 22562478

Foveal light exposure is increased at the time of removal of silicone oil with the potential for phototoxicity.

Mahmut Dogramaci1, Katie Williams, Ed Lee, Tom H Williamson.   

Abstract

BACKGROUND: There is sudden and dramatic visual function deterioration in 1-10 % of eyes filled with silicone oil at the time of removal of silicon oil. Transmission of high-energy blue light is increased in eyes filled with silicone oil. We sought to identify if increased foveal light exposure is a potential factor in the pathophysiology of the visual loss at the time of removal of silicone oil.
METHODS: A graphic ray tracing computer program and laboratory models were used to determine the effect of the intraocular silicone oil bubble size on the foveal illuminance at the time of removal of silicone oil under direct microscope light. The graphic ray tracing computer program revealed a range of optical vignetting effects created by different sizes of silicone oil bubble within the vitreous cavity giving rise to an uneven macular illumination. The laboratory model was used to quantify the variation of illuminance at the foveal region with different sizes of silicone oil bubble with in the vitreous cavity at the time of removal of silicon oil under direct microscope light. To substantiate the hypothesis of the light toxicity during removal of silicone oil, The outcome of oil removal procedures performed under direct microscope illumination in compared to those performed under blocked illumination.
RESULTS: The computer program showed that the optical vignetting effect at the macula was dependent on the size of the intraocular silicone oil bubble. The laboratory eye model showed that the foveal illuminance followed a bell-shaped curve with 70 % greater illuminance demonstrated at with 50-60 % silicone oil fill. The clinical data identified five eyes with unexplained vision loss out of 114 eyes that had the procedure performed under direct microscope illumination compared to none out of 78 eyes that had the procedure under blocked illumination.
CONCLUSIONS: Foveal light exposure, and therefore the potential for phototoxicity, is transiently increased at the time of removal of silicone oil. This is due to uneven macular illumination resulting from the optical vignetting effect of different silicone oil bubble sizes. The increase in foveal light exposure may be significant when the procedure is performed under bright operating microscope light on already stressed photoreceptors of an eye filled with silicon oil. We advocate the use of precautions, such as central shadow filter on the operating microscope light source to reduce foveal light exposure and the risk of phototoxicity at the time of removal of silicone oil. The graphic ray tracing computer program used in this study shows promise in eye modeling for future studies.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22562478     DOI: 10.1007/s00417-012-2033-5

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  21 in total

1.  The use of liquid silicone in retinal detachment surgery.

Authors:  P A CIBIS; B BECKER; E OKUN; S CANAAN
Journal:  Arch Ophthalmol       Date:  1962-11

2.  Light effects on mitochondrial photosensitizers in relation to retinal degeneration.

Authors:  N N Osborne; T A Kamalden; A S A Majid; S del Olmo-Aguado; A G Manso; D Ji
Journal:  Neurochem Res       Date:  2010-10-07       Impact factor: 3.996

3.  Failure of potassium siphoning by Müller cells: a new hypothesis of perfluorocarbon liquid-induced retinopathy.

Authors:  M Winter; W Eberhardt; C Scholz; A Reichenbach
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-01       Impact factor: 4.799

4.  Visual loss after silicone oil removal.

Authors:  E N Herbert; S H M Liew; T H Williamson
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

Review 5.  Light-induced damage to the retina: role of rhodopsin chromophore revisited.

Authors:  Małgorzata Rózanowska; Tadeusz Sarna
Journal:  Photochem Photobiol       Date:  2005 Nov-Dec       Impact factor: 3.421

6.  Loss of vision once silicone oil has been removed.

Authors:  Khami Satchi; Anne Bolton; Chetan K Patel
Journal:  Retina       Date:  2005-09       Impact factor: 4.256

7.  Long-term prognosis after removal of silicone oil.

Authors:  G Lesnoni; T Rossi; A Nistri; B Boccassini
Journal:  Eur J Ophthalmol       Date:  2000 Jan-Mar       Impact factor: 2.597

8.  Central scotoma associated with intraocular silicone oil tamponade develops before oil removal.

Authors:  E N Herbert; M Habib; D Steel; T H Williamson
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-07-27       Impact factor: 3.117

9.  Sudden visual loss after removal of silicone oil.

Authors:  Richard S B Newsom; Robert Johnston; Paul M Sullivan; G Bill Aylward; Graham E Holder; Zdenek J Gregor
Journal:  Retina       Date:  2004-12       Impact factor: 4.256

10.  Interactions between light and vitreous fluid substitutes.

Authors:  C Azzolini; F Docchio; R Brancato; G Trabucchi
Journal:  Arch Ophthalmol       Date:  1992-10
View more
  10 in total

1.  Vision loss under silicone oil tamponade.

Authors:  Jan Tode; Konstantine Purtskhvanidze; Till Oppermann; Jost Hillenkamp; Felix Treumer; Johann Roider
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-06-08       Impact factor: 3.117

2.  The incidence of silicone oil-related visual loss following the removal of heavy silicone oil.

Authors:  J Y X Lee; R Sawant; A Jonas; J Lochhead
Journal:  Eye (Lond)       Date:  2019-07-02       Impact factor: 3.775

3.  Multifocal electroretinogram in eyes with intravitreal silicone oil and changes following silicone oil removal.

Authors:  Devesh Kumawat; Pranita Sahay; Karthikeyan Mahalingam; S J Vikas; Sagnik Sen; Mousumi Banerjee; Pradeep Venkatesh
Journal:  Doc Ophthalmol       Date:  2019-07-20       Impact factor: 2.379

Review 4.  [Visual acuity reduction and silicone oil tamponade].

Authors:  Armin Wolf; Mario R Romano; Christos Haritoglou
Journal:  Ophthalmologie       Date:  2022-08-02

5.  The incidence of unexplained visual loss following removal of silicone oil.

Authors:  R Moya; A Chandra; P J Banerjee; D Tsouris; N Ahmad; D G Charteris
Journal:  Eye (Lond)       Date:  2015-08-07       Impact factor: 3.775

6.  Un-explained visual loss following silicone oil removal: results of the Pan American Collaborative Retina Study (PACORES) Group.

Authors:  Jose A Roca; Lihteh Wu; Maria Berrocal; Francisco Rodriguez; Arturo Alezzandrini; Gustavo Alvira; Raul Velez-Montoya; Hugo Quiroz-Mercado; J Fernando Arevalo; Martín Serrano; Luiz H Lima; Marta Figueroa; Michel Farah; Giovanna Chico
Journal:  Int J Retina Vitreous       Date:  2017-07-24

7.  Experimental model to evaluate the benefits of lutein to prevent retinal phototoxicity during pars plana vitrectomy surgery using xenon source light illumination in rabbits.

Authors:  Anderson Teixeira; Eduardo A Novais; Emmerson Badaró; Acácio Lima; Michel Eid Farah; Rubens Belfort
Journal:  Int J Retina Vitreous       Date:  2019-05-07

8.  Foveal Microvascular Structures in Eyes with Silicone Oil Tamponade for Rhegmatogenous Retinal Detachment: A Swept-source Optical Coherence Tomography Angiography Study.

Authors:  Jong Young Lee; Jin Young Kim; Sang-Yoon Lee; Jin Ho Jeong; Eun Kyoung Lee
Journal:  Sci Rep       Date:  2020-02-13       Impact factor: 4.379

9.  Microvascular changes on optical coherence tomography angiography after rhegmatogenous retinal detachment vitrectomy with silicone tamponade.

Authors:  Ji Hye Lee; Young Gun Park
Journal:  PLoS One       Date:  2021-03-12       Impact factor: 3.240

Review 10.  Retinal and Corneal Changes Associated with Intraocular Silicone Oil Tamponade.

Authors:  Mariantonia Ferrara; Giulia Coco; Tania Sorrentino; Kirti M Jasani; George Moussa; Francesco Morescalchi; Felipe Dhawahir-Scala; Francesco Semeraro; David H W Steel; Vito Romano; Mario R Romano
Journal:  J Clin Med       Date:  2022-09-05       Impact factor: 4.964

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.