Literature DB >> 22562399

Is there an equivalence of non-invasive to invasive referenciation in computer-aided surgery?

Tanja D Grauvogel1, Juergen Grauvogel, Susan Arndt, Ansgar Berlis, Wolfgang Maier.   

Abstract

Various navigation systems with non-invasive patient referenciation and registration methods have been developed in times of minimal-invasive and computer-aided surgery. However, hard data proving the equivalence of different referenciation systems are missing. The present study investigated invasive and non-invasive referenciation systems with regard to overall navigation accuracy as well as navigation accuracy at specific anatomic locations. Four skull models were individually fabricated with a 3D printer based on patient's CT data sets and fitted with an individual customized silicone skin. 26 titanium screws on defined anatomic locations served as target fiducials. Two non-invasive referenciation systems (headband and headset) were compared with the invasive skull fixed reference array. Registration was done with laser surface scan. The mean accuracy was calculated and the target registration error for eight anatomical locations was measured. Mean accuracy was 1.3 ± 0.12 mm for the skull fixed reference array, 1.44 ± 0.24 mm for the headset and 1.46 ± 0.15 mm for the headband referenciation (non-significant). Navigation accuracy of the invasive referenciation system was significantly superior to the accuracy of both non-invasive systems on the ethmoid sinus with respect to the selected anatomic locations. In the midface headband referenciation was statistically significantly worse than the invasive system. Invasive and non-invasive referenciation systems seem to be on par in terms of overall navigation accuracy, but not regarding specific anatomic locations. Therefore, invasive referenciation systems should be preferred in high precision surgery.

Entities:  

Mesh:

Year:  2012        PMID: 22562399     DOI: 10.1007/s00405-012-2023-6

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  26 in total

Review 1.  [Computer-aided 3D-navigation systems. Survey and location determination].

Authors:  A R Gunkel; W F Thumfart; W Freysinger
Journal:  HNO       Date:  2000-02       Impact factor: 1.284

Review 2.  Present state and future perspectives of computer aided surgery in the field of ENT and skull base.

Authors:  Marco Caversaccio; Lutz-Peter Nolte; Rudolf Häusler
Journal:  Acta Otorhinolaryngol Belg       Date:  2002

3.  Contour and paired-point registration in a model for image-guided surgery.

Authors:  P Daniel Knott; Pete S Batra; Robert S Butler; Martin J Citardi
Journal:  Laryngoscope       Date:  2006-10       Impact factor: 3.325

4.  Comparison of laser surface scanning and fiducial marker-based registration in frameless stereotaxy. Technical note.

Authors:  Kurt Schicho; Michael Figl; Rudolf Seemann; Markus Donat; Michael L Pretterklieber; Wolfgang Birkfellner; Astrid Reichwein; Felix Wanschitz; Franz Kainberger; Helmar Bergmann; Arne Wagner; Rolf Ewers
Journal:  J Neurosurg       Date:  2007-04       Impact factor: 5.115

5.  Surface laser registration in ENT-surgery: accuracy in the paranasal sinuses--a cadaveric study.

Authors:  Georg J Ledderose; Klaus Stelter; Andreas Leunig; Hjalmar Hagedorn
Journal:  Rhinology       Date:  2007-12       Impact factor: 3.681

6.  Laser surface registration for lateral skull base surgery.

Authors:  R Marmulla; G Eggers; J Mühling
Journal:  Minim Invasive Neurosurg       Date:  2005-06

7.  Quantification of true in vivo (application) accuracy in cranial image-guided surgery: influence of mode of patient registration.

Authors:  Christopher R Mascott; Jean-Christophe Sol; Philippe Bousquet; Jacques Lagarrigue; Yves Lazorthes; Valérie Lauwers-Cances
Journal:  Neurosurgery       Date:  2006-07       Impact factor: 4.654

8.  Registration accuracy and practicability of laser-directed surface matching.

Authors:  J Schlaier; J Warnat; A Brawanski
Journal:  Comput Aided Surg       Date:  2002

9.  [CAS of the paranasal sinuses--technology and clinical experience with the Vector-Vision-Compact-System in 102 patients].

Authors:  G Grevers; A Leunig; A Klemens; H Hagedorn
Journal:  Laryngorhinootologie       Date:  2002-07       Impact factor: 1.057

Review 10.  Errors and error management in image-guided craniomaxillofacial surgery.

Authors:  Gerlig Widmann; Rudolf Stoffner; Reto Bale
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-05
View more
  2 in total

1.  A preregistered STAMP method for image-guided temporal bone surgery.

Authors:  Masamichi Oka; Byunghyun Cho; Nozomu Matsumoto; Jaesung Hong; Misaki Jinnouchi; Riichi Ouchida; Shizuo Komune; Makoto Hashizume
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-06-26       Impact factor: 2.924

2.  Registration using 3D-printed rigid templates outperforms manually scanned surface matching in image-guided temporal bone surgery.

Authors:  Makoto Yamashita; Nozomu Matsumoto; Byunghyun Cho; Noritaka Komune; Shinya Onogi; Jongseung Lee; Jordan Bano; Tomohiko Akahoshi; Makoto Hashizume
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-14       Impact factor: 2.924

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.