Literature DB >> 22560309

Peritherapeutic quantitative flow analysis of arteriovenous malformation on digital subtraction angiography.

Tzung-Chi Huang1, Tung-Hsin Wu, Chung-Jung Lin, Greta S P Mok, Wan-Yuo Guo.   

Abstract

BACKGROUND: Digital subtraction angiography (DSA) provides detailed hemodynamic information. However, the imaging interpretation is mainly based on the physician's experience and observation. We aimed to quantitatively study the peritherapeutic blood flow changes of a cerebral arteriovenous malformation (AVM) treated by embolization using optical flow estimation on DSA.
METHODS: A 37-year-old woman with an AVM in the right frontal lobe of her brain was enrolled. The optical flow method with a pixel-by-pixel measurement was applied to determine the blood flow in brain vessels on anterior-posterior and lateral DSA views before and after embolization.
RESULTS: A return toward normalization of blood flow as a result of embolization was determined semiquantitatively on the posttherapeutic DSA.
CONCLUSIONS: Optical flow analysis on DSA illustrated the potential of quantifying intracranial blood flows in patients with cerebral vascular disorders and the therapeutic effects.
Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22560309     DOI: 10.1016/j.jvs.2012.02.041

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Changes of time-attenuation curve blood flow parameters in patients with and without carotid stenosis.

Authors:  C-J Lin; F-C Chang; W-Y Guo; S-C Hung; C-B Luo; J Beilner; M Kowarschik; W-F Chu
Journal:  AJNR Am J Neuroradiol       Date:  2015-02-26       Impact factor: 3.825

2.  Quantitative evaluation of arteriovenous malformation hemodynamic changes after endovascular treatment using parametric color coding: A case series study.

Authors:  Rodrigo Rivera; Juan G Sordo; Daniel Echeverria; Lautaro Badilla; Camila Pinto; Catalina Merino-Osorio
Journal:  Interv Neuroradiol       Date:  2017-08-01       Impact factor: 1.610

3.  Patient-individualized boundary conditions for CFD simulations using time-resolved 3D angiography.

Authors:  Marco Boegel; Sonja Gehrisch; Thomas Redel; Christopher Rohkohl; Philip Hoelter; Arnd Doerfler; Andreas Maier; Markus Kowarschik
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-03-26       Impact factor: 2.924

4.  Effect of injection technique on temporal parametric imaging derived from digital subtraction angiography in patient specific phantoms.

Authors:  Ciprian N Ionita; Victor L Garcia; Daniel R Bednarek; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-13

5.  Arteriovenous malformation of the thyroid gland as a very rare cause of mechanical neck syndrome: a case report.

Authors:  Monika Černá; Vladislav Třeška; Michal Krčma; Ondřej Daum; František Šlauf
Journal:  J Med Case Rep       Date:  2015-02-02

6.  Automatic flow analysis of digital subtraction angiography using independent component analysis in patients with carotid stenosis.

Authors:  Han-Jui Lee; Jia-Sheng Hong; Chung-Jung Lin; Yi-Hsuan Kao; Feng-Chi Chang; Chao-Bao Luo; Wei-Fa Chu
Journal:  PLoS One       Date:  2017-09-26       Impact factor: 3.240

7.  Evaluation of superficial femoral artery-lesions after percutaneous transluminal angioplasty: color-coded summation images vs. monochromatic digital subtraction angiography.

Authors:  Anne Marie Augustin; Irina Thein; Nicole Rickert; Thorsten Klink; Thorsten Alexander Bley; Ralph Kickuth
Journal:  BMC Med Imaging       Date:  2020-06-18       Impact factor: 1.930

8.  Quantification of blood flow in internal cerebral artery by optical flow method on digital subtraction angiography in comparison with time-of-flight magnetic resonance angiography.

Authors:  Tzung-Chi Huang; Chih-Kai Chang; Chun-Han Liao; Yung-Jen Ho
Journal:  PLoS One       Date:  2013-01-24       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.