A new device for performing reference point indentation without a reference probe.

Daniel Bridges1, Connor Randall, Paul K Hansma.   

Abstract

Here we describe a novel, hand-held reference point indentation (RPI), instrument that is designed for clinical measurements of bone material properties in living patients. This instrument differs from previous RPI instruments in that it requires neither a reference probe nor removal of the periosteum that covers the bone, thus significantly simplifying its use in patient testing. After describing the instrument, we discuss five guidelines for optimal and reproducible results. These are: (1) the angle between the normal to the surface and the axis of the instrument should be less than 10°, (2) the compression of the main spring to trigger the device must be performed slowly (>1 s), (3) the probe tip should be sharper than 10 μm; however, a normalized parameter with a calibration phantom can correct for dull tips up to a 100 μm radius, (4) the ambient room temperature should be between 4 °C and 37 °C, and (5) the effective mass of the bone or material under test must exceed 1 kg, or if under 1 kg, the specimen should be securely anchored in a fixation device with sufficient mass (which is not a requirement of previous RPI instruments). Our experience is that a person can be trained with these guidelines in about 5 min and thereafter obtain accurate and reproducible results. The portability, ease of use, and minimal training make this instrument suitable to measure bone material properties in a clinical setting.
© 2012 American Institute of Physics

Entities:  

Mesh:

Year:  2012        PMID: 22559552      PMCID: PMC3331866          DOI: 10.1063/1.3693085

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  8 in total

Review 1.  Insights into material and structural basis of bone fragility from diseases associated with fractures: how determinants of the biomechanical properties of bone are compromised by disease.

Authors:  P Chavassieux; E Seeman; P D Delmas
Journal:  Endocr Rev       Date:  2006-12-19       Impact factor: 19.871

2.  The bone diagnostic instrument II: indentation distance increase.

Authors:  Paul Hansma; Patricia Turner; Barney Drake; Eugene Yurtsev; Alexander Proctor; Phillip Mathews; Jason Lulejian; Jason Lelujian; Connor Randall; Jonathan Adams; Ralf Jungmann; Federico Garza-de-Leon; Georg Fantner; Haykaz Mkrtchyan; Michael Pontin; Aaron Weaver; Morton B Brown; Nadder Sahar; Ricardo Rossello; David Kohn
Journal:  Rev Sci Instrum       Date:  2008-06       Impact factor: 1.523

3.  Changes in the impact energy absorption of bone with age.

Authors:  J D Currey
Journal:  J Biomech       Date:  1979       Impact factor: 2.712

4.  Estimation of the Young's modulus of articular cartilage using an arthroscopic indentation instrument and ultrasonic measurement of tissue thickness.

Authors:  J Töyräs; T Lyyra-Laitinen; M Niinimäki; R Lindgren; M T Nieminen; I Kiviranta; J S Jurvelin
Journal:  J Biomech       Date:  2001-02       Impact factor: 2.712

5.  The tissue diagnostic instrument.

Authors:  Paul Hansma; Hongmei Yu; David Schultz; Azucena Rodriguez; Eugene A Yurtsev; Jessica Orr; Simon Tang; Jon Miller; Joseph Wallace; Frank Zok; Cheng Li; Richard Souza; Alexander Proctor; Davis Brimer; Xavier Nogues-Solan; Leonardo Mellbovsky; M Jesus Peña; Oriol Diez-Ferrer; Phillip Mathews; Connor Randall; Alfred Kuo; Carol Chen; Mathilde Peters; David Kohn; Jenni Buckley; Xiaojuan Li; Lisa Pruitt; Adolfo Diez-Perez; Tamara Alliston; Valerie Weaver; Jeffrey Lotz
Journal:  Rev Sci Instrum       Date:  2009-05       Impact factor: 1.523

Review 6.  Age-dependent biomechanical modifications in bone.

Authors:  Deepak Vashishth
Journal:  Crit Rev Eukaryot Gene Expr       Date:  2005       Impact factor: 1.807

7.  Indentation instrument for the measurement of cartilage stiffness under arthroscopic control.

Authors:  T Lyyra; J Jurvelin; P Pitkänen; U Väätäinen; I Kiviranta
Journal:  Med Eng Phys       Date:  1995-07       Impact factor: 2.242

8.  Microindentation for in vivo measurement of bone tissue mechanical properties in humans.

Authors:  Adolfo Diez-Perez; Roberto Güerri; Xavier Nogues; Enric Cáceres; Maria Jesus Peña; Leonardo Mellibovsky; Connor Randall; Daniel Bridges; James C Weaver; Alexander Proctor; Davis Brimer; Kurt J Koester; Robert O Ritchie; Paul K Hansma
Journal:  J Bone Miner Res       Date:  2010-08       Impact factor: 6.741

  8 in total
  40 in total

1.  Deep atomic force microscopy.

Authors:  H Barnard; B Drake; C Randall; P K Hansma
Journal:  Rev Sci Instrum       Date:  2013-12       Impact factor: 1.523

2.  In vivo assessment of bone quality in postmenopausal women with type 2 diabetes.

Authors:  Joshua N Farr; Matthew T Drake; Shreyasee Amin; L Joseph Melton; Louise K McCready; Sundeep Khosla
Journal:  J Bone Miner Res       Date:  2014-04       Impact factor: 6.741

3.  Local bone quality measurements correlates with maximum screw torque at the femoral diaphysis.

Authors:  Christopher M McAndrew; Avinesh Agarwalla; Adam C Abraham; Eric Feuchtbaum; William M Ricci; Simon Y Tang
Journal:  Clin Biomech (Bristol, Avon)       Date:  2018-02-03       Impact factor: 2.063

4.  In vivo reference point indentation measurement variability in skeletally mature inbred mice.

Authors:  Andrew Srisuwananukorn; Matthew R Allen; Drew M Brown; Joseph M Wallace; Jason M Organ
Journal:  Bonekey Rep       Date:  2015-06-17

Review 5.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

Review 6.  Bone Quality in Chronic Kidney Disease: Definitions and Diagnostics.

Authors:  Erin M B McNerny; Thomas L Nickolas
Journal:  Curr Osteoporos Rep       Date:  2017-06       Impact factor: 5.096

Review 7.  Skeletal changes through the lifespan--from growth to senescence.

Authors:  Joshua N Farr; Sundeep Khosla
Journal:  Nat Rev Endocrinol       Date:  2015-06-02       Impact factor: 43.330

8.  Applications of a New Handheld Reference Point Indentation Instrument Measuring Bone Material Strength.

Authors:  Connor Randall; Daniel Bridges; Roberto Guerri; Xavier Nogues; Lluis Puig; Elisa Torres; Leonardo Mellibovsky; Kevin Hoffseth; Tyler Stalbaum; Ananya Srikanth; James C Weaver; Sasha Rosen; Heather Barnard; Davis Brimer; Alex Proctor; James Candy; Christopher Saldana; Srinivasan Chandrasekar; Timothy Lescun; Carrie M Nielson; Eric Orwoll; Doug Herthel; Hal Kopeikin; Henry T Y Yang; Joshua N Farr; Louise McCready; Sundeep Khosla; Adolfo Diez-Perez; Paul K Hansma
Journal:  J Med Device       Date:  2013-09-24       Impact factor: 0.582

Review 9.  Determinants of bone strength and quality in diabetes mellitus in humans.

Authors:  Joshua N Farr; Sundeep Khosla
Journal:  Bone       Date:  2015-07-26       Impact factor: 4.398

Review 10.  Are we taking full advantage of the growing number of pharmacological treatment options for osteoporosis?

Authors:  Karl J Jepsen; Stephen H Schlecht; Kenneth M Kozloff
Journal:  Curr Opin Pharmacol       Date:  2014-04-16       Impact factor: 5.547

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.