Literature DB >> 22553670

Clinic study on silicone hydrogel contact lenses used as bandage contact lenses after LASEK surgery.

Xiao-Mei Qu1, Jin-Hui Dai, Zhen-Ying Jiang, Yi-Feng Qian.   

Abstract

AIM: To compare the clinical performance of two types of silicon hydrogel contact lenses used as bandage lenses after LASEK surgery.
METHODS: A prospective, double-masked study was conducted on 42 eyes of 21 patients who received binocular LASEK surgeries. The interocular difference in spherical equivalent power was less than -1.50D. Patients were randomly assigned to wear Galyfilcon A (Lens A) bandage contact lens in one eye and Balafilcon A (Lens B) in the fellow eye after the surgery. The responses to a subjective questionnaire on comfort of wearing, corneal epithelial status, conjunctival hyperemia, limbal neovascularization, lens fitting and contact lens debris were assessed 1 and 5 days postoperatively. Corneal endothelium was assessed before and 5 days after the surgery upon bandage lens removal.
RESULTS: There was no difference between the two groups in terms of conjunctival hyperemia, limbal neovascularization, contact lens fitting, corneal epithelial status, corneal endothelium cell density (CD) and endothelium cell size (CS) at any postoperative visit. Complaints of discomfort, including foreign body sensation, pain and intolerance were statistically more among Lens B wearers at any postoperative visit (P<0.05). Lens B appeared to attract much more debris than Lens A at the 5-day post-operative follow-up visit (P<0.01).
CONCLUSION: The two types of silicon hydrogel lenses investigated in this study demonstrated similar clinical performance in terms of corneal responses and lens fitting. However, Lens A showed a better performance in terms of comfort of wearing and deposit resistance.

Entities:  

Keywords:  LASEK; bandage contact lens; silicone hydrogel contact lens; therapeutic contact lens

Year:  2011        PMID: 22553670      PMCID: PMC3340826          DOI: 10.3980/j.issn.2222-3959.2011.03.22

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  13 in total

1.  Comparative study of two silicone hydrogel contact lenses used as bandage contact lenses after LASEK.

Authors:  Raquel Gil-Cazorla; Miguel A Teus; Jose L Hernández-Verdejo; Laura De Benito-Llopis; Monsterrat García-González
Journal:  Optom Vis Sci       Date:  2008-09       Impact factor: 1.973

2.  Effect of long-term contact lens wear on corneal endothelial cell morphology and function.

Authors:  K H Carlson; W M Bourne; R F Brubaker
Journal:  Invest Ophthalmol Vis Sci       Date:  1988-02       Impact factor: 4.799

3.  Effects of laser in situ keratomileusis on the corneal endothelium.

Authors:  Chun-Chi Chiang; Jane-Ming Lin; Pei-Jane Bair; Wen-Lu Chen; Sung-Huei Tseng; Yi-Yu Tsai
Journal:  Kaohsiung J Med Sci       Date:  2005-06       Impact factor: 2.744

4.  Epi-LASEK for the correction of myopia and myopic astigmatism.

Authors:  Nicole J Anderson; Robin F Beran; Timothy L Schneider
Journal:  J Cataract Refract Surg       Date:  2002-08       Impact factor: 3.351

5.  Efficacy of 2 types of silicone hydrogel bandage contact lenses after photorefractive keratectomy.

Authors:  Michael A Grentzelos; Sotiris Plainis; Nikolaos I Astyrakakis; Vasilios F Diakonis; George D Kymionis; Panagiotis Kallinikos; Ioannis G Pallikaris
Journal:  J Cataract Refract Surg       Date:  2009-12       Impact factor: 3.351

6.  Comparison of silicone and non-silicone hydrogel soft contact lenses used as a bandage after LASEK.

Authors:  Raquel Gil-Cazorla; Miguel A Teus; Esther Arranz-Márquez
Journal:  J Refract Surg       Date:  2008-02       Impact factor: 3.573

7.  Therapeutic use of a lotrafilcon A silicone hydrogel soft contact lens as a bandage after LASEK surgery.

Authors:  Jacek P Szaflik; Anna M Ambroziak; Jerzy Szaflik
Journal:  Eye Contact Lens       Date:  2004-01       Impact factor: 2.018

8.  Oxygen permeability of hydrogel contact lenses with organosilicon moieties.

Authors:  V Compañ; A Andrio; A López-Alemany; E Riande; M F Refojo
Journal:  Biomaterials       Date:  2002-07       Impact factor: 12.479

9.  Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses.

Authors:  B A Holden; G W Mertz
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-10       Impact factor: 4.799

10.  Microbiologic study of soft contact lenses after laser subepithelial keratectomy for myopia.

Authors:  Ahmet Hondur; Kamil Bilgihan; Meltem Yalinay Cirak; Ozgur Dogan; Alper Erdinc; Berati Hasanreisoglu
Journal:  Eye Contact Lens       Date:  2008-01       Impact factor: 2.018

View more
  6 in total

1.  Comparative evaluation of Comfilcon A and Senofilcon A bandage contact lenses after transepithelial photorefractive keratectomy.

Authors:  Achyut Mukherjee; Antonis Ioannides; Ioannis Aslanides
Journal:  J Optom       Date:  2014-06-13

2.  Comparation of effectiveness of silicone hydrogel contact lens and hydrogel contact lens in patients after LASEK.

Authors:  Wen-Juan Xie; Jin Zeng; Ying Cui; Juan Li; Zhong-Ming Li; Wei-Xiong Liao; Xiao-Hong Yang
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

3.  Clinical Observation of Silicon Hydrogel Contact Lens Fitted Immediately after Small Incision Lenticule Extraction (SMILE).

Authors:  Jifang Wang; Shuxin Xi; Bingjie Wang; Zhi Chen; Ke Zheng; Xingtao Zhou
Journal:  J Ophthalmol       Date:  2020-08-19       Impact factor: 1.909

4.  Effect of Ethylene Oxide Sterilization on Polyvinyl Alcohol Hydrogel Compared with Gamma Radiation.

Authors:  Grace Pohan; Sabrina Mattiassi; Yuan Yao; Aung Moe Zaw; Deirdre E J Anderson; Marie F A Cutiongco; Monica T Hinds; Evelyn K F Yim
Journal:  Tissue Eng Part A       Date:  2020-05-28       Impact factor: 3.845

5.  Comparing the effects of two different contact lenses on corneal re-epithelialization after corneal collagen cross-linking.

Authors:  Yusuf Kocluk; Savas Cetinkaya; Emine Alyamac Sukgen; Murat Günay; Alper Mete
Journal:  Pak J Med Sci       Date:  2017 May-Jun       Impact factor: 1.088

6.  Bandage Contact Lens Application Reduces Fibrotic Wound Healing of Flap Margins after FS-LASIK: A Prospective Randomized Clinical Trial.

Authors:  Li-Quan Zhao; Liang-Mao Li; Jun Liu; Peng Li
Journal:  J Ophthalmol       Date:  2019-01-10       Impact factor: 1.909

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.