Literature DB >> 22552175

A comparison of lead placement through the subclavian vein technique with fluoroscopy-guided axillary vein technique for permanent pacemaker insertion.

Gautam Sharma1, Nagendra Boopathy Senguttuvan, Ajit Thachil, Darryl Leong, Nitish Naik, Rakesh Yadav, Rajnish Juneja, Vinay K Bahl.   

Abstract

BACKGROUND: The intrathoracic subclavian venous technique for pacemaker implantation may be associated with serious complications. We describe an alternative technique for obtaining venous access for pacemaker implantation through axillary vein under fluoroscopic guidance and compare it with the conventional, subclavian approach.
METHODS: We conducted a single-centre, prospective, nonrandomized study. All adult patients with indication for permanent pacing who consented were recruited during a 3-year period. To access the axillary vein, we used the alternative technique with a new fluoroscopic landmark. The subclavian access was obtained as per the usual approach.
RESULTS: We studied 478 lead placements during 3 years; 315 lead placements through axillary venous technique (group 1) were compared with 163 lead placements through subclavian venous technique (group 2). Both routes had a high and comparable success rate, 98.09% in group 1 and 96.93% in group 2. The axillary approach was successful at the first attempt in 194 punctures (61.6%), as vs 60 in group 2 (36.8%) P < 0.0001. The average number of attempts in group 1 was 2.06 per patient and 2.56 in group 2 (P < 0.001). There were 3 (2.94%) pneumothoraxes in group 2 and none in group 1. During a mean follow-up period of 3.2 months in group1 and 3.7 months in group 2, 1 patient in group 2 had a lead fracture.
CONCLUSIONS: The fluoroscopically guided axillary venous approach for implanting permanent pacemakers is equivalent to the traditional anatomic landmark-guided intrathoracic subclavian approach and has fewer complications and shorter procedural time to access the vein.
Copyright © 2012 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22552175     DOI: 10.1016/j.cjca.2012.02.019

Source DB:  PubMed          Journal:  Can J Cardiol        ISSN: 0828-282X            Impact factor:   5.223


  8 in total

1.  Axillary vein puncture using fluoroscopic landmarks: a safe and effective approach for implantable cardioverter defibrillator leads.

Authors:  Federico Migliore; Mariachiara Siciliano; Manuel De Lazzari; Sonia Ferretto; Chiara Dalla Valle; Alessandro Zorzi; Domenico Corrado; Sabino Iliceto; Emanuele Bertaglia
Journal:  J Interv Card Electrophysiol       Date:  2015-05-09       Impact factor: 1.900

2.  Comparison of left ventricular systolic function and mechanical dyssynchrony using equilibrium radionuclide angiography in patients with right ventricular outflow tract versus right ventricular apical pacing: A prospective single-center study.

Authors:  Harmandeep Singh; Chetan D Patel; Gautam Sharma; Nitish Naik
Journal:  J Nucl Cardiol       Date:  2015-01-23       Impact factor: 5.952

3.  Efficacy of ultrasound-guided axillary/subclavian venous approaches for pacemaker and defibrillator lead implantation: a randomized study.

Authors:  Mattia Liccardo; Pasquale Nocerino; Salzano Gaia; Carmine Ciardiello
Journal:  J Interv Card Electrophysiol       Date:  2018-01-15       Impact factor: 1.900

4.  Intermittent Pacemaker Malfunction Caused by Continuous Compression of the Lead by the Clavicle (Subclavian Crush Syndrome).

Authors:  Ardian Rizal; Evit Ruspiono; Dinarsari Hayuning Putri
Journal:  Eur J Case Rep Intern Med       Date:  2020-05-27

5.  Optimized Axillary Vein Technique versus Subclavian Vein Technique in Cardiovascular Implantable Electronic Device Implantation: A Randomized Controlled Study.

Authors:  Peng Liu; Yi-Feng Zhou; Peng Yang; Yan-Sha Gao; Gui-Ru Zhao; Shi-Yan Ren; Xian-Lun Li
Journal:  Chin Med J (Engl)       Date:  2016-11-20       Impact factor: 2.628

6.  Scoring System Assessment of Cephalic Vein Access for Device Implantation.

Authors:  Jane Taleski; Lidija Poposka; Filip Janusevski; Bekim Pocesta; Vladimir Boskov; Noel G Boyle
Journal:  J Innov Card Rhythm Manag       Date:  2018-08-15

7.  Paced QRS duration predicts left ventricular function in patients with permanent pacemakers - One-year follow-up study using equilibrium radionuclide angiography (ERNA).

Authors:  Gautam Sharma; Sudhir Suryakant Shetkar; Chetan D Patel; Harmandeep Singh; Nitish Naik; Ambuj Roy; Rajnish Juneja; Prashanthan Sanders
Journal:  Indian Pacing Electrophysiol J       Date:  2015-07-13

8.  Sex differences in CRT device implantation rates, efficacy, and complications following implantation: protocol for a systematic review and meta-analysis of cohort studies.

Authors:  Vivian Welch; George A Wells; Omar Dewidar; David Birnie; Irina Podinic
Journal:  Syst Rev       Date:  2021-07-23
  8 in total