Literature DB >> 22547354

Protein determination in serum and whole blood by attenuated total reflectance infrared spectroscopy.

D Perez-Guaita1, J Ventura-Gayete, C Pérez-Rambla, M Sancho-Andreu, S Garrigues, M de la Guardia.   

Abstract

Attenuated total reflectance mid-infrared spectra of serum and blood samples were obtained from 4,000 to 600 cm(-1). Models for the determination of albumin, immunoglobulin, total globulin, and albumin/globulin coefficients were established for serum samples, using reference data obtained by capillary electrophoresis. Based on the use of the amide bands I and II regions, the relative root mean square error of prediction (RRMSEP) was 4.9, 14.9, 4.5, and 7.1% for albumin, immunoglobulin, total globulin, and albumin/globulin coefficients, respectively, determined in an independent validation set of 120 samples using 200 samples for calibration. Additionally, the use of Kennard-Stone method for the selection of a representative calibration subset of samples provided comparable results using only 60 samples. For whole blood analysis, hemoglobin was determined in 40 validation samples using models built from 40 calibration independent samples with RRMSEP of 8.3, 5.5, and 4.9% with models built from direct spectra in the first case and from sample spectra recorded after lysis by sodium dodecyl sulfate and freezing, respectively, for the last two ones. The developed methodologies offer green alternatives for patient diagnosis in a few minutes, minimizing the use of reagents and residues and being adaptable for its use as a point-of-care method.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22547354     DOI: 10.1007/s00216-012-6030-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  A Combined Near-Infrared and Mid-Infrared Spectroscopic Approach for the Detection and Quantification of Glycine in Human Serum.

Authors:  Thulya Chakkumpulakkal Puthan Veettil; Bayden R Wood
Journal:  Sensors (Basel)       Date:  2022-06-15       Impact factor: 3.847

Review 2.  Potential of Raman spectroscopy for the analysis of plasma/serum in the liquid state: recent advances.

Authors:  Drishya Rajan Parachalil; Jennifer McIntyre; Hugh J Byrne
Journal:  Anal Bioanal Chem       Date:  2020-01-03       Impact factor: 4.142

3.  Estimation of the age of human bloodstains under the simulated indoor and outdoor crime scene conditions by ATR-FTIR spectroscopy.

Authors:  Hancheng Lin; Yinming Zhang; Qi Wang; Bing Li; Ping Huang; Zhenyuan Wang
Journal:  Sci Rep       Date:  2017-10-16       Impact factor: 4.379

4.  Complex refractive index spectra of whole blood and aqueous solutions of anticoagulants, analgesics and buffers in the mid-infrared.

Authors:  David J Rowe; David Smith; James S Wilkinson
Journal:  Sci Rep       Date:  2017-08-04       Impact factor: 4.379

5.  Reagent-free total protein quantification of intact extracellular vesicles by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy.

Authors:  Veronika Szentirmai; András Wacha; Csaba Németh; Diána Kitka; Anita Rácz; Károly Héberger; Judith Mihály; Zoltán Varga
Journal:  Anal Bioanal Chem       Date:  2020-05-29       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.