Literature DB >> 22543970

Magnetic resonance perfusion of the myocardium: semiquantitative and quantitative evaluation in comparison with coronary angiography and fractional flow reserve.

Armin Huber1, Steven Sourbron, Volker Klauss, Julia Schaefer, Kerstin Ulrike Bauner, Michael Schweyer, Maximilian Reiser, Ernst Rummeny, Johannes Rieber.   

Abstract

PURPOSE: The aim of this study was to investigate if a quantitative evaluation of a magnetic resonance (MR) perfusion examination of the myocardium can achieve a comparable diagnostic accuracy as a semiquantitative evaluation.
METHODS: A total of 31 patients with suspected coronary artery disease underwent MR imaging and conventional coronary angiography. Stenoses with a diameter reduction between 50% and 75% were evaluated by an intracoronary pressure wire examination (fractional flow reserve) for assessment of their hemodynamic relevance. A 0.05 mmol/kg contrast material bolus (gadopentetate dimeglumine) was applied during adenosine-induced stress (140 μg/kg/min) and at rest with a flow rate of 5 mL/s. Signal intensity time curves of the first-pass MR perfusion images, acquired at rest and under adenosine stress with a Saturation Recovery-turbo Fast Low Angle Shot Magnetic Resonance Imaging sequence, were analyzed by Argus Dynamic Signal Analysis (Siemens Healthcare, Erlangen, Germany). For the semiquantitative evaluation, the upslope value of a linear fit from the foot point to the signal maximum was calculated for 18 segments (signal intensity units per second). For the quantitative evaluation, a model-independent deconvolution was used to calculate coronary blood flow (MBF in mL/100 g/min). For each segment for the stress and rest examination, upslope value and MBF were determined. In addition, the ratio of the stress and rest value for each segment was determined (myocardial perfusion reserve index [MPRI]). The mean value of the 2 segments with the lowest value was calculated for each patient. Coronary artery stenosis greater than 75% or greater than 50% with positive fractional flow reserve less than 0.75 was considered as hemodynamically relevant. Receiver-operator-curves were calculated.
RESULTS: The values of the area under the ROC curves were 0.74, 0.66, and 0.92 for the US(Stress), US(Rest), and US(MPRI) evaluations (semiquantitative evaluation). The values for the MBF(Stress), MBF(Rest), and MBF(MPRI) evaluations (quantitative evaluation) were 0.92, 0.68, and 0.84, respectively. Comparing US(MPRI) and MBF(Stress), identical values and no significant difference were found for the area under the ROC curves.
CONCLUSION: A quantitative evaluation using a model-free deconvolution provides identical diagnostic performance when only a stress examination is used, much similar to a semiquantitative evaluation, if both stress and rest examinations are used.

Entities:  

Mesh:

Year:  2012        PMID: 22543970     DOI: 10.1097/RLI.0b013e31824f54cb

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  17 in total

Review 1.  Reasons and implications of agreements and disagreements between coronary flow reserve, fractional flow reserve, and myocardial perfusion imaging.

Authors:  Manish Motwani; Mahsaw Motlagh; Anuj Gupta; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2015-12-29       Impact factor: 5.952

Review 2.  Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer.

Authors:  Michael Ingrisch; Steven Sourbron
Journal:  J Pharmacokinet Pharmacodyn       Date:  2013-04-06       Impact factor: 2.745

3.  Investigation into diagnostic accuracy of common strategies for automated perfusion motion correction.

Authors:  Constantine Zakkaroff; John D Biglands; John P Greenwood; Sven Plein; Roger D Boyle; Aleksandra Radjenovic; Derek R Magee
Journal:  J Med Imaging (Bellingham)       Date:  2016-05-13

4.  Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole.

Authors:  Manish Motwani; Ananth Kidambi; Steven Sourbron; Timothy A Fairbairn; Akhlaque Uddin; Sebastian Kozerke; John P Greenwood; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2014-02-24       Impact factor: 5.364

5.  Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy.

Authors:  John D Biglands; Derek R Magee; Steven P Sourbron; Sven Plein; John P Greenwood; Aleksandra Radjenovic
Journal:  Radiology       Date:  2014-12-18       Impact factor: 11.105

6.  Quantification of myocardial blood flow with cardiovascular magnetic resonance throughout the cardiac cycle.

Authors:  Manish Motwani; Ananth Kidambi; Akhlaque Uddin; Steven Sourbron; John P Greenwood; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2015-01-29       Impact factor: 5.364

7.  Myocardial perfusion is impaired in asymptomatic renal and liver transplant recipients: a cardiovascular magnetic resonance study.

Authors:  Susie Parnham; Jonathan M Gleadle; Darryl Leong; Suchi Grover; Craig Bradbrook; Richard J Woodman; Carmine G De Pasquale; Joseph B Selvanayagam
Journal:  J Cardiovasc Magn Reson       Date:  2015-07-10       Impact factor: 5.364

8.  Multimodality quantitative assessments of myocardial perfusion using dynamic contrast enhanced magnetic resonance and 15O-labelled water positron emission tomography imaging.

Authors:  G Papanastasiou; M C Williams; M R Dweck; S Mirsadraee; N Weir; A Fletcher; C Lucatelli; D Patel; E J R van Beek; D E Newby; S I K Semple
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-01-23

9.  Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography.

Authors:  Katharina Ikuye; Dominik Buckert; Lisa Schaaf; Thomas Walcher; Wolfgang Rottbauer; Peter Bernhardt
Journal:  J Cardiovasc Magn Reson       Date:  2013-03-27       Impact factor: 5.364

10.  Evaluation of a comprehensive cardiovascular magnetic resonance protocol in young adults late after the arterial switch operation for d-transposition of the great arteries.

Authors:  Daniel Tobler; Manish Motwani; Rachel M Wald; Susan L Roche; Flavia Verocai; Robert M Iwanochko; John P Greenwood; Erwin N Oechslin; Andrew M Crean
Journal:  J Cardiovasc Magn Reson       Date:  2014-12-11       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.