Pyrocarbon proximal interphalangeal joint arthroplasty: minimum two-year follow-up.

A C Watts1, A J Hearnden, I A Trail, M J Hayton, D Nuttall, J K Stanley.   

Abstract

PURPOSE: To report the outcome and complications from pyrocarbon proximal interphalangeal (PIP) joint arthroplasty at a minimum of 2 years of follow-up.
METHODS: A retrospective case review was performed on 72 patients with an average age of 57 years, and a total of 97 pyrocarbon PIP joint arthroplasties. Patient demographics, diagnosis, implant revisions, and other repeat surgeries were recorded. Subjective outcome was evaluated at latest follow-up with the Disabilities of the Arm, Shoulder, and Hand score; Patient Evaluation Measure; and visual analog scores of pain, satisfaction, and appearance. Objective outcomes included PIP joint range of motion, grip strength, and radiographic assessment of alignment and loosening.
RESULTS: The principal diagnosis was primary osteoarthritis in 43 patients(60%), posttraumatic arthritis in 14 (19%), rheumatoid arthritis in 9 (13%), and psoriatic arthritis in 6 (8%). The average follow-up was 60 months (range, 24-108 mo). Twenty-two of 97 digits (23%) had repeat surgery without revision, and 13 digits (13%) had revision at an average of 15 months. There were no significant differences in preoperative and postoperative range of motion. The average Disabilities of the Arm, Shoulder, and Hand score was 22, and the average pain score was zero. Implant migration and loosening was observed but was not related to clinical outcome or revision.
CONCLUSIONS: The survival of pyrocarbon PIP joint arthroplasty was 85% (83 of 97) at 5 years of follow-up, with high patient satisfaction. Patients should be advised that the procedure achieves good relief of pain but does not improve range of motion. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22541153     DOI: 10.1016/j.jhsa.2012.02.012

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  8 in total

1.  Outcomes of Surface Replacement Proximal Interphalangeal Joint Arthroplasty Through a Volar Approach: A Prospective Study.

Authors:  Thomas E Trumble; Dennis J Heaton
Journal:  Hand (N Y)       Date:  2016-08-03

2.  Factors Associated with Reoperation after Pyrocarbon Proximal Interphalangeal Joint Arthroplasty for the Arthritic Joint: A Retrospective Cohort Study.

Authors:  Bo J W Notermans; Jonathan Lans; Ryan P Ponton; Jesse B Jupiter; Neal C Chen
Journal:  J Hand Microsurg       Date:  2020-04-09

3.  Surface Replacement Arthroplasty Using a Volar Approach for Osteoarthritis of Proximal Interphalangeal Joint: Results After a Minimum 5-Year Follow-up.

Authors:  Ken Shirakawa; Masahiko Shirota
Journal:  Hand (N Y)       Date:  2018-07-17

Review 4.  Proximal interphalangeal (PIP) joint replacements with pyrolytic carbon implants in the hand.

Authors:  Massimo Ceruso; Sandra Pfanner; Christian Carulli
Journal:  EFORT Open Rev       Date:  2017-03-13

5.  Novel Use of Joint Replacement in a Thumb Interphalangeal Joint.

Authors:  Desirae McKee; E L Domingo-Johnson
Journal:  Case Rep Orthop       Date:  2019-04-15

6.  Functional Outcomes for Meniscal Allograft Interposition Arthroplasty of the Hand.

Authors:  Meghan C McCullough; Raquel Minasian; Kylie Tanabe; Sandra Rodriguez; David Kulber
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-04-20

7.  Systematic review of the introduction, early phase study and evaluation of pyrocarbon proximal interphalangeal joint arthroplasty.

Authors:  Paul Welford; Natalie S Blencowe; Emily Pardington; Conor S Jones; Jane M Blazeby; Barry G Main
Journal:  PLoS One       Date:  2021-10-19       Impact factor: 3.752

Review 8.  Silicone and Pyrocarbon Artificial Finger Joints.

Authors:  F A Alnaimat; H A Owida; A Al Sharah; M Alhaj; Mohammad Hassan
Journal:  Appl Bionics Biomech       Date:  2021-06-03       Impact factor: 1.781

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.