Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners.

Mohammad Reza Ay1, Abolfazl Mehranian, Asghar Maleki, Hossien Ghadiri, Pardis Ghafarian, Habib Zaidi.   

Abstract

Beam hardening filters have long been employed in X-ray Computed Tomography (CT) to preferentially absorb soft and low-energy X-rays having no or little contribution to image formation, thus allowing the reduction of patient dose and beam hardening artefacts. In this work, we studied the influence of additional copper (Cu) and aluminium (Al) flat filters on patient dose and image quality and seek an optimum filter thickness for the GE LightSpeed VCT 64-slice CT scanner using experimental phantom measurements. Different thicknesses of Cu and Al filters (0.5-1.6mm Cu, 0.5-4mm Al) were installed on the scanner's collimator. A planar phantom consisting of 13 slabs of Cu having different thicknesses was designed and scanned to assess the impact of beam filtration on contrast in the intensity domain (CT detector's output). To assess image contrast and image noise, a cylindrical phantom consisting of a polyethylene cylinder having 16 holes filled with different concentrations of K2HPO4 solution mimicking different tissue types was used. The GE performance and the standard head CT dose index (CTDI) phantoms were also used to assess image resolution characterized by the modulation transfer function (MTF) and patient dose defined by the weighted CTDI. A 100mm pencil ionization chamber was used for CTDI measurement. Finally, an optimum filter thickness was determined from an objective figure of merit (FOM) metric. The results show that the contrast is somewhat compromised with filter thickness in both the planar and cylindrical phantoms. The contrast of the K2HPO4 solutions in the cylindrical phantom was degraded by up to 10% for a 0.68mm Cu filter and 6% for a 4.14mm Al filter. It was shown that additional filters increase image noise which impaired the detectability of low density K2HPO4 solutions. It was found that with a 0.48mm Cu filter the 50% MTF value is shifted by about 0.77lp/cm compared to the case where the filter is not used. An added Cu filter with approximately 0.5mm thickness accounts for 50% reduction in radiation-absorbed dose as measured by the weighted CTDI. The FOM results indicate that with an additional filter of 0.5mm Cu or minimum 4mm Al, a good compromise between image quality and patient dose is achieved for CT images acquired at tube voltages of 120 and 140kVp. The results seem to indicate that an optimum filter for high kVp acquisitions, routinely used in cardiovascular imaging, should be 0.5mm copper or 4mm aluminium minimum.
Copyright © 2012 Associazione Italiana di Fisica Medica. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22541061     DOI: 10.1016/j.ejmp.2012.03.005

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  6 in total

1.  Estimation of Radiation Dose in CT Based on Projection Data.

Authors:  Xiaoyu Tian; Zhye Yin; Bruno De Man; Ehsan Samei
Journal:  J Digit Imaging       Date:  2016-10       Impact factor: 4.056

2.  Characterization and comparison of imaging contrast enhancement with PEG-functionalized gold nanoparticles in kV cone beam computed tomography and computed tomography imaging.

Authors:  Tara Gray; Nema Bassiri; Shaquan David; Devanshi Yogeshkumar Patel; Mohammad Abdul-Moqueet; Neil Kirby; Kathryn M Mayer
Journal:  Biomed Phys Eng Express       Date:  2020-05-29

3.  Fast analytical approach of application specific dose efficient spectrum selection for diagnostic CT imaging and PET attenuation correction.

Authors:  Xue Rui; Yannan Jin; Paul F FitzGerald; Mingye Wu; Adam M Alessio; Paul E Kinahan; Bruno De Man
Journal:  Phys Med Biol       Date:  2016-10-18       Impact factor: 3.609

4.  Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography.

Authors:  Nivedita Rana; Dinesh Rawat; Madan Parmar; Devinder Kumar Dhawan; Ashok Kumar Bhati; Bhagwant Rai Mittal
Journal:  J Med Phys       Date:  2015 Oct-Dec

5.  Dual-energy computed tomography using a gantry-based preclinical cone-beam microcomputed tomography scanner.

Authors:  Justin J Tse; Joy Dunmore-Buyze; Maria Drangova; David W Holdsworth
Journal:  J Med Imaging (Bellingham)       Date:  2018-08-21

6.  Assessment and comparison of radiation dose and image quality in multi-detector CT scanners in non-contrast head and neck examinations.

Authors:  Daryoush Khoramian; Soroush Sistani; Razzagh Abedi Firouzjah
Journal:  Pol J Radiol       Date:  2019-01-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.