Literature DB >> 22535813

Acutrak versus Herbert screw fixation for scaphoid non-union and delayed union.

Kayode O Oduwole1, Benedikt Cichy, John P Dillon, Joan Wilson, John O'Beirne.   

Abstract

PURPOSE: To compare the treatment outcome of Acutrak versus Herbert screw fixation for scaphoid non-union and delayed union.
METHODS: Records of 132 patients who underwent Herbert screw fixation (n=61) or Acutrak screw fixation (n=71) with or without bone grafting for scaphoid non-union and delayed union by a single surgeon were reviewed. The most common fracture site was the waist of the scaphoid (n=95), followed by the proximal pole (n=31) and the distal pole (n=6). Screw placement was considered accurate (n=120) when the screw was placed in the central one-third (axially) of the scaphoid; otherwise it was eccentric (n=12). Bone union was assessed radiographically and clinically. Functional outcome was assessed using the modified Mayo wrist score.
RESULTS: Respectively in the Herbert and Acutrak screw groups, the mean patient ages were 25.3 and 27.3 years (p=0.28), the mean intervals between injury and screw fixation were 12.2 and 17 months (p=0.38), the mean durations to bone union were 2.1 and 1.8 months (p=0.63), and the union rates were 77% and 93% (p=0.01). The union rate was significantly higher in fractures of the waist of the scaphoid than in the proximal and distal poles (94% vs. 71% vs. 33%, p=0.001). The union rate was significantly higher when the screw was placed accurately (axially) than eccentrically (Herbert screw: 84% vs. 40%, p=0.006; Acutrak screw: 96% vs. 0%, p=0.004). 84% of the Herbert screws were placed axially, compared to 97% for the Acutrak screws. Respectively, 67% and 85% of patients had satisfactory functional outcomes (p=0.03), whereas 23% and 7% of the patients had persistent non-union (p=0.05).
CONCLUSION: The Acutrak screw enabled more accurate screw placement and achieved higher union rates and modified Mayo wrist scores than the Herbert screw did.

Entities:  

Mesh:

Year:  2012        PMID: 22535813     DOI: 10.1177/230949901202000112

Source DB:  PubMed          Journal:  J Orthop Surg (Hong Kong)        ISSN: 1022-5536            Impact factor:   1.118


  3 in total

1.  Insertion profiles of 4 headless compression screws.

Authors:  Adam Hart; Edward J Harvey; Louis-Philippe Lefebvre; Francois Barthelat; Reza Rabiei; Paul A Martineau
Journal:  J Hand Surg Am       Date:  2013-06-25       Impact factor: 2.230

2.  Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws.

Authors:  Lukas Filli; Magda Marcon; Bernhard Scholz; Maurizio Calcagni; Tim Finkenstädt; Gustav Andreisek; Roman Guggenberger
Journal:  Skeletal Radiol       Date:  2014-08-28       Impact factor: 2.199

3.  How to ease the fixation of carpal bones? Twenty-four lesions treated by 1,5 mm headless compression screws.

Authors:  Andrea Poggetti; Chiara Suardi; Giulio Lauri; David Espen; Prospero Bigazzi; Sandra Pfanner
Journal:  J Clin Orthop Trauma       Date:  2021-04-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.