Effects of frequency compression hearing aids for unilaterally implanted children with acoustically amplified residual hearing in the nonimplanted ear.

Lisa R Park1, Holly F B Teagle, Emily Buss, Patricia A Roush, Craig A Buchman.   

Abstract

OBJECTIVES: The primary objective of this study is to evaluate the benefits of nonlinear frequency compression (NLFC) hearing aids in the nonimplanted ears of children with unilateral cochlear implants (CIs). It is hypothesized that speech perception performance will benefit from complementary auditory cues provided by the CI and the hearing aid, particularly with the increased access to high-frequency sounds provided by NLFC.
DESIGN: Eleven children using unilateral CIs with usable residual hearing in the nonimplanted ears were enrolled in the study and fitted with NLFC hearing aids. The test protocol included consonant-nucleus-consonant words in quiet, the Hearing in Noise Test sentences presented in speech noise and two-talker maskers, and a consonant identification task. Subjects were tested in a CI-alone condition as well as bimodally, with and without NLFC enabled.
RESULTS: The results support previous work in adults and children, demonstrating the beneficial effects of bimodal listening. Frequency compression did not significantly affect performance for the children enrolled in this study, although some preferred using NLFC. The results yield suggestions regarding test methods for pediatric bimodal listeners, and considerations regarding validation and audibility of the compressed signal.
CONCLUSIONS: Hearing aid use in the contralateral ear of unilaterally implanted children is beneficial. Children and young adults who are fitted bimodally should be tested both in quiet and in complex listening situations to determine bimodal benefit. In the current test battery, the inclusion of frequency compression in the hearing aid fitting does not seem to provide significant improvement beyond standard hearing aid fittings or any bilateral interference symptoms for this group of bimodal listeners.

Entities:  

Mesh:

Year:  2012        PMID: 22531574     DOI: 10.1097/AUD.0b013e31824a3b97

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  5 in total

1.  Evaluation of hearing aid frequency response fittings in pediatric and young adult bimodal recipients.

Authors:  Lisa S Davidson; Jill B Firszt; Chris Brenner; Jamie H Cadieux
Journal:  J Am Acad Audiol       Date:  2015-04       Impact factor: 1.664

2.  Audibility and Spectral-Ripple Discrimination Thresholds as Predictors of Word Recognition with Nonlinear Frequency Compression.

Authors:  Marc A Brennan; Ryan W McCreery
Journal:  J Am Acad Audiol       Date:  2022-02-17       Impact factor: 1.245

3.  Spatial Release From Masking in Pediatric Cochlear Implant Recipients With Single-Sided Deafness.

Authors:  Lisa R Park; Margaret T Dillon; Emily Buss; Brendan P O'Connell; Kevin D Brown
Journal:  Am J Audiol       Date:  2021-03-26       Impact factor: 1.636

4.  Quality ratings of frequency-compressed speech by participants with extensive high-frequency dead regions in the cochlea.

Authors:  Marina Salorio-Corbetto; Thomas Baer; Brian C J Moore
Journal:  Int J Audiol       Date:  2016-10-11       Impact factor: 2.117

5.  The Benefits of Bimodal Aiding on Extended Dimensions of Speech Perception: Intelligibility, Listening Effort, and Sound Quality.

Authors:  Elke M J Devocht; A Miranda L Janssen; Josef Chalupper; Robert J Stokroos; Erwin L J George
Journal:  Trends Hear       Date:  2017 Jan-Dec       Impact factor: 3.293

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.