Risk of ionising radiation to trainee orthopaedic surgeons.

Ishrat A Khan1, Senthil Kamalasekaran, M Ali Fazal.   

Abstract

We undertook this study to determine the amount of scattered radiation received by the primary surgeon, assistant and patient during dynamic hip screw fixation for proximal femoral fractures. Data was collected from fifty patients. Five registrars were included as operating surgeon and four senior house officers as assistant surgeon. Radiation was monitored by thermo luminescent dosimeters placed on the surgeon and assistant. The approximate distance of surgeon and assistant from the operative site was measured. A dosimeter on the unaffected hip of patients measured the radiation to the patient. The results show that the surgeon's dominant hand receives the highest dose of radiation and radiation exposure is dependent on the experience of the operator. Our study concludes that exposure to radiation during this procedure is well below the toxic levels; however greater awareness is needed for harmful effects of exposure to long term low dose radiation.

Entities:  

Mesh:

Year:  2012        PMID: 22523936

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  7 in total

1.  Assessing Wire Navigation Performance in the Operating Room.

Authors:  Leah K Taylor; Geb W Thomas; Matthew D Karam; Clarence D Kreiter; Donald D Anderson
Journal:  J Surg Educ       Date:  2016-05-12       Impact factor: 2.891

2.  The Effect of C-Arm Mobility and Field of Vision on Radiation Exposure in the Treatment of Proximal Femoral Fractures: A Randomized Clinical Trial.

Authors:  Mahmut Kalem; Kerem Başarır; Hakan Kocaoğlu; Ercan Şahin; Hakan Kınık
Journal:  Biomed Res Int       Date:  2018-03-27       Impact factor: 3.411

3.  A Report on Occupational Ionizing Radiation Exposure by an Orthopedic Surgeon in a National Health-care Setting - Clinical Case Perspective.

Authors:  Abdulbaset Abosala
Journal:  J Orthop Case Rep       Date:  2018 May-Jun

Review 4.  Improved Radiation Exposure Monitoring of Orthopaedic Residents After Institution of a Personalized Lead Protocol.

Authors:  Patrick A Massey; Mitchell E Myers; Ryan D Guedry; Michael T Lowery; Kevin J Perry; R Shane Barton
Journal:  JB JS Open Access       Date:  2022-03-21

5.  A New Preoperative Planning Technique Can Reduce Radiation Exposure During the Performance of Medial Opening-Wedge High Tibial Osteotomy.

Authors:  Elad Spitzer; Joseph J Ruzbarsky; John B Doyle; Kaitlyn L Yin; Robert G Marx
Journal:  HSS J       Date:  2017-12-26

6.  Teaching basic trauma: validating FluoroSim, a digital fluoroscopic simulator for guide-wire insertion in hip surgery.

Authors:  Kapil Sugand; Robert A Wescott; Richard Carrington; Alister Hart; Bernard H Van Duren
Journal:  Acta Orthop       Date:  2018-05-10       Impact factor: 3.717

7.  Development of Neuromonitoring Pedicle Screw - Results of Electrical Resistance and Neurophysiologic Test in Pig Model.

Authors:  Woo-Seok Bang; Jonghoo Park; Kyoung-Tae Kim; Dae-Chul Cho; K Daniel Riew; Du-Hwan Kim; In-Bo Han; Seung-Jae Hyun; Do-Heum Yoon; Young-Baeg Kim
Journal:  Neurospine       Date:  2020-11-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.