Literature DB >> 22520797

Development of transcatheter aortic valve implantation (TAVI): a 20-year odyssey.

Alain Cribier1.   

Abstract

The development of transcatheter aortic valve implantation (TAVI) by our group has been a 20-year odyssey. In 1993, postmortem studies validated the concept of intravalvular stenting in calcific aortic stenosis. The first prototypes of balloon-expandable valves were tested in an animal model in 2000. The first-in-man implantation was performed in Rouen in 2002, rapidly followed by two prospective series in compassionate cases in our centre. TAVI took flight in 2004 in the hands of Edwards Lifesciences, with major improvements in devices and approaches. At the same time, the self-expanding CoreValve was launched. Thousands of high-surgical-risk patients were enrolled in feasibility studies, leading to the Conformité Européenne (CE) mark being granted in 2007 for the two devices. A number of postmarketing registries have shown dramatic improvements in procedural and midterm results and decreased complication rates, with more experience and improved technology. The results of the randomized PARTNER study in the USA recently confirmed the important place of TAVI in non-operable and high-surgical-risk patients. To date, more than 50,000 patients have benefited from TAVI worldwide (2300 patients in 33 centres in France in 2011) and the number is consistently increasing. An optimal multidisciplinary collaboration and formally trained experienced physicians are the keys to success. An extension of indications to lower-risk patients might be expected in the coming years but should be cautiously investigated. Ten years after the first-in-man case, TAVI is here to stay and the future is promising.
Copyright © 2012 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22520797     DOI: 10.1016/j.acvd.2012.01.005

Source DB:  PubMed          Journal:  Arch Cardiovasc Dis        ISSN: 1875-2128            Impact factor:   2.340


  27 in total

1.  Self-Expanding Stent and Delivery System for Aortic Valve Replacement.

Authors:  Dumitru Mazilu; Ming Li; Ozgur Kocaturk; Keith A Horvath
Journal:  J Med Device       Date:  2012-11-01       Impact factor: 0.582

2.  Development of self-expanding valved stents with autologous tubular leaflet tissues for transcatheter valve implantation.

Authors:  Marina Funayama; Hirohito Sumikura; Yoshiaki Takewa; Eisuke Tatsumi; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2015-02-12       Impact factor: 1.731

3.  Aerosol-generating procedures and risk of transmission of acute respiratory infections: a systematic review.

Authors:  K Tran; K Cimon; M Severn; Cl Pessoa-Silva; J Conly
Journal:  CADTH Technol Overv       Date:  2013-02-01

Review 4.  Clinical significance of conduction disturbances after aortic valve intervention: current evidence.

Authors:  Manuel Martinez-Selles; Peter Bramlage; Martin Thoenes; Gerhard Schymik
Journal:  Clin Res Cardiol       Date:  2014-07-04       Impact factor: 5.460

Review 5.  Role of Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Corinna Storz; Tobias Geisler; Mike Notohamiprodjo; Konstantin Nikolaou; Fabian Bamberg
Journal:  Curr Treat Options Cardiovasc Med       Date:  2016-10

6.  The importance of contrast volume/glomerular filtration rate ratio in contrast-induced nephropathy patients after transcatheter aortic valve implantation.

Authors:  Ilker Gul; Mustafa Zungur; Ahmet Tastan; Faik Fevzi Okur; Ertan Damar; Samet Uyar; Veysel Sahin; Talat Tavli
Journal:  Cardiorenal Med       Date:  2014-12-20       Impact factor: 2.041

7.  Predictive Value of the Mehran Score for Contrast-Induced Nephropathy after Transcatheter Aortic Valve Implantation in Patients with Aortic Stenosis.

Authors:  Mustafa Zungur; Ilker Gul; Ahmet Tastan; Ertan Damar; Talat Tavli
Journal:  Cardiorenal Med       Date:  2016-05-05       Impact factor: 2.041

8.  Development of a stent-biovalve with round-shaped leaflets: in vitro hydrodynamic evaluation for transcatheter pulmonary valve implantation (TPVI).

Authors:  Hirohito Sumikura; Yasuhide Nakayama; Kentaro Ohnuma; Yoshiaki Takewa; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2016-05-26       Impact factor: 1.731

9.  Experience of a high-risk aortic valve clinic in Ireland.

Authors:  K E O'Sullivan; S A Early; I Casserly; Z Chugtai; D Sugrue; J Hurley
Journal:  Ir J Med Sci       Date:  2014-02-01       Impact factor: 1.568

10.  Practical update on imaging and transcatheter aortic valve implantation.

Authors:  Gisela Feltes; Iván J Núñez-Gil
Journal:  World J Cardiol       Date:  2015-04-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.