Literature DB >> 22511584

Left ventricular end-diastolic pressure as an independent predictor of outcome during balloon aortic valvuloplasty.

Roberto J Cubeddu1, Creighton W Don, Sofia A Horvath, Pritha P Gupta, Ignacio Cruz-Gonzalez, Christian Witzke, Ignacio Inglessis, Igor F Palacios.   

Abstract

OBJECTIVES: In this study, we examined the predictive value of the left ventricular end-diastolic pressure (LVEDP) in patients undergoing balloon aortic valvuloplasty (BAV).
BACKGROUND: The LVEDP is a useful indicator of hemodynamic status in patients with severe aortic stenosis. In BAV, decompensated heart failure is associated with worse outcomes.
METHODS: We identified all consecutive patients with severe symptomatic aortic stenosis who underwent retrograde BAV at the Massachusetts General Hospital from 2004 to 2008. Patients were stratified and compared according to their baseline LVEDP into ≤15 mm Hg, 16-20 mm Hg, 21-25 mm Hg, and ≥26 mm Hg. Procedural and in-hospital outcomes and adverse events were compared. Multivariate logistic regression was used for the adjusted analysis.
RESULTS: A total of 111 patients with a mean age of 83±11 years underwent BAV. Of these, the LVEDP was ≤15 mm Hg in 29 (26%), 16-20 mm Hg in 41 (37%), 21-25 mm Hg in 16 (14%), and ≥26 mm Hg in 25 (23%) patients. Baseline characteristics were similar among the four groups. Noticeably, patients with high LVEDP levels had significantly higher rates of the combined endpoint of in-hospital death, myocardial infarction (MI), cardiopulmonary arrest, and tamponade was P = 0.02. Periprocedural MI was more common among those with higher LVEDP (16% vs. 2.3%; P = 0.04). Multivariate analysis revealed LVEDP (OR 1.08, for each mm Hg increase in pressure, 95 % CI 1.02-1.14), small LV chamber size, and New York Heart Association class as independent predictors of adverse outcomes.
CONCLUSIONS: The LVEDP is an important independent predictor of poor in-hospital outcome during BAV. In these patients, the immediate hemodynamic status may be more important than the baseline left ventricular systolic function. Hemodynamic optimization before or during BAV should be considered and may be beneficial.
Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

Entities:  

Keywords:  TAVI; balloon aortic valvuloplasty; outcome LVEDP; predictors

Mesh:

Year:  2013        PMID: 22511584      PMCID: PMC4188857          DOI: 10.1002/ccd.24410

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  22 in total

1.  Determinants of one-year outcome from balloon aortic valvuloplasty.

Authors:  C J Davidson; J K Harrison; K S Pieper; M Harding; J B Hermiller; K Kisslo; C Pierce; T M Bashore
Journal:  Am J Cardiol       Date:  1991-07-01       Impact factor: 2.778

2.  Percutaneous transluminal aortic valvuloplasty: acute outcome and follow-up of 125 patients.

Authors:  R F Lewin; G Dorros; J F King; L Mathiak
Journal:  J Am Coll Cardiol       Date:  1989-11-01       Impact factor: 24.094

3.  Predictors of event-free survival after balloon aortic valvuloplasty.

Authors:  R E Kuntz; A N Tosteson; A D Berman; L Goldman; P C Gordon; B M Leonard; R G McKay; D J Diver; R D Safian
Journal:  N Engl J Med       Date:  1991-07-04       Impact factor: 91.245

4.  Aortic stenosis in elderly patients aged 80 or older. Treatment by percutaneous balloon valvuloplasty in a series of 92 cases.

Authors:  B Letac; A Cribier; R Koning; E Lefebvre
Journal:  Circulation       Date:  1989-12       Impact factor: 29.690

5.  Balloon aortic valvuloplasty in adults: failure of procedure to improve long-term survival.

Authors:  E B Lieberman; T M Bashore; J B Hermiller; J S Wilson; K S Pieper; G P Keeler; C H Pierce; K B Kisslo; J K Harrison; C J Davidson
Journal:  J Am Coll Cardiol       Date:  1995-11-15       Impact factor: 24.094

6.  Percutaneous transluminal aortic valvuloplasty--the acute outcome and follow-up of 149 patients who underwent the double balloon technique.

Authors:  G Dorros; R F Lewin; S H Stertzer; J F King; B F Waller; R K Myler; L Mathiak; M Murphy; R E Shaw; J Assa
Journal:  Eur Heart J       Date:  1990-05       Impact factor: 29.983

7.  Percutaneous balloon aortic valvuloplasty. Acute and 30-day follow-up results in 674 patients from the NHLBI Balloon Valvuloplasty Registry.

Authors: 
Journal:  Circulation       Date:  1991-12       Impact factor: 29.690

8.  Three-year outcome after balloon aortic valvuloplasty. Insights into prognosis of valvular aortic stenosis.

Authors:  C M Otto; M C Mickel; J W Kennedy; E L Alderman; T M Bashore; P C Block; J A Brinker; D Diver; J Ferguson; D R Holmes
Journal:  Circulation       Date:  1994-02       Impact factor: 29.690

9.  Predictors of long-term survival after percutaneous aortic valvuloplasty: report of the Mansfield Scientific Balloon Aortic Valvuloplasty Registry.

Authors:  W W O'Neill
Journal:  J Am Coll Cardiol       Date:  1991-01       Impact factor: 24.094

10.  The role of percutaneous aortic balloon valvuloplasty in patients with cardiogenic shock and critical aortic stenosis.

Authors:  P R Moreno; I K Jang; J B Newell; P C Block; I F Palacios
Journal:  J Am Coll Cardiol       Date:  1994-04       Impact factor: 24.094

View more
  2 in total

1.  An epicardial delivery of nitroglycerine by active hydraulic ventricular support drug delivery system improves cardiac function in a rat model.

Authors:  Xue Li; Reyaj Mikrani; Cunyu Li; Muhammad Naveed; Ziwei Liu; Muhammad Abbas; Yijie Cheng; Lei Han; Zhijie Wang; Xiaohui Zhou
Journal:  Drug Deliv Transl Res       Date:  2020-02       Impact factor: 4.617

2.  Long-term results of percutaneous balloon valvuloplasty of congenital aortic stenosis in adolescents and young adults.

Authors:  Neeraj Awasthy; Ria Garg; S Radhakrishnan; Savitri Shrivastava
Journal:  Indian Heart J       Date:  2016-03-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.