Balloon aortic valvuloplasty in adults: failure of procedure to improve long-term survival.

E B Lieberman1, T M Bashore, J B Hermiller, J S Wilson, K S Pieper, G P Keeler, C H Pierce, K B Kisslo, J K Harrison, C J Davidson.   

Abstract

OBJECTIVES: This study sought to determine the long-term outcome of adult patients undergoing percutaneous balloon aortic valvuloplasty.
BACKGROUND: Percutaneous balloon aortic valvuloplasty has been offered as an alternative to aortic valve replacement for selected patients with valvular aortic stenosis. Although balloon aortic valvuloplasty produces an immediate reduction in the transvalvular aortic gradient, a high incidence of restenosis frequently leads to recurrent symptoms. Therefore, it is unclear whether balloon aortic valvuloplasty impacts on the long-term outcome of these patients.
METHODS: Clinical, hemodynamic and echocardiographic data were collected at baseline in 165 patients undergoing balloon aortic valvuloplasty and examined for their ability to predict long-term outcome.
RESULTS: The median duration follow-up was 3.9 years (range 1 to 6). Ninety-nine percent follow-up was achieved. During this 6-year period, 152 patients (93%) died or underwent aortic valve replacement, and 99 (60%) died of cardiac-related causes. The probability of event-free survival (freedom from death, aortic valve replacement or repeat balloon aortic valvuloplasty) 1, 2 and 3 years after valvuloplasty was 40%, 19% and 6%, respectively. In contrast, the probability of survival 3 years after balloon aortic valvuloplasty in a subset of 42 patients who underwent subsequent aortic valve replacement was 84%. Survival after aortic valvuloplasty was poor regardless of the presenting symptom, but patients with New York Heart Association functional class IV congestive heart failure had events earliest. Univariable predictors of decreased event-free survival were younger age, advanced congestive heart failure symptoms, lower ejection fraction, elevated left ventricular end-diastolic pressure, presence of coronary artery disease and increased left ventricular internal diastolic diameter. Stepwise multivariable logistic regression analysis found that only younger age and a lower left ventricular ejection fraction contributed independent adverse prognostic information (chi-square 14.89, p = 0.0006).
CONCLUSIONS: Long-term event-free and actuarial survival after balloon aortic valvuloplasty is dismal and resembles the natural history of untreated aortic stenosis. Aortic valve replacement may be performed in selected subjects with good results. However, the prognosis for the remainder of patients who are not candidates for aortic valve replacement is particularly poor.

Entities:  

Mesh:

Year:  1995        PMID: 7594080     DOI: 10.1016/0735-1097(95)00363-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  40 in total

Review 1.  Which strategy for a protein crystallization project?

Authors:  C E Kundrot
Journal:  Cell Mol Life Sci       Date:  2004-03       Impact factor: 9.261

2.  A case of severe aortic stenosis with severe coronary artery disease that was successfully treated by balloon aortic valvuloplasty and percutaneous coronary intervention.

Authors:  Yuichiro Maekawa; Akio Kawamura; Akira Furuta; Shinsuke Yuasa; Keiichi Fukuda
Journal:  Heart Vessels       Date:  2011-11-11       Impact factor: 2.037

3.  Temporary support with Tandemheart pVAD during percutaneous aortic valve replacement in an animal model: rationale and methodology.

Authors:  Biswajit Kar; Reynolds M Delgado; Andrew B Civitello; Pranav Loyalka; David Paniagua; R David Fish; Matthew D Forrester; Daniel Moser; Branislav Radovancevic
Journal:  Tex Heart Inst J       Date:  2005

4.  [Anesthesia with transfemoral and transapical aortic valve implantation. Periinterventional management and hemodynamic observations].

Authors:  Lars Bergmann; Eva Kottenberg; Torsten Heine; Philipp Kahlert; Holger Eggebrecht; Daniel Wendt; Matthias Thielmann; Heinz Jakob; Raimund Erbel; Jürgen Peters
Journal:  Herz       Date:  2009-08       Impact factor: 1.443

Review 5.  Percutaneous aortic valve replacement.

Authors:  John G Webb
Journal:  Curr Cardiol Rep       Date:  2008-03       Impact factor: 2.931

Review 6.  In vivo imaging and computational analysis of the aortic root. Application in clinical research and design of transcatheter aortic valve systems.

Authors:  Paul Schoenhagen; Alexander Hill; Tim Kelley; Zoran Popovic; Sandra S Halliburton
Journal:  J Cardiovasc Transl Res       Date:  2011-04-12       Impact factor: 4.132

7.  Percutaneous aortic valve implantation: the anesthesiologist perspective.

Authors:  R D Covello; G Landoni; I Michev; E Bignami; L Ruggeri; F Maisano; M Montorfano; O Alfieri; A Colombo; A Zangrillo
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2009

Review 8.  Valvular heart disease: diagnosis and management.

Authors:  Kameswari Maganti; Vera H Rigolin; Maurice Enriquez Sarano; Robert O Bonow
Journal:  Mayo Clin Proc       Date:  2010-05       Impact factor: 7.616

9.  Timing of surgery in aortic stenosis.

Authors:  Siva B Mohan; George A Stouffer
Journal:  Curr Treat Options Cardiovasc Med       Date:  2006-12

Review 10.  [Decompensated valve failure: the revival of balloon valvuloplasty - percutaneous valve intervention].

Authors:  Stefan Sack; Jochen Menne; Thomas Krüger; Michael Weber; Dieter Müller; Werner Zwehl
Journal:  Herz       Date:  2009-05       Impact factor: 1.443