Evaluating the noise in electrically evoked compound action potential measurements in cochlear implants.

Jaime A Undurraga1, Robert P Carlyon, Jan Wouters, Astrid van Wieringen.   

Abstract

Electrically evoked compound action potentials (ECAPs) are widely used to study the excitability of the auditory nerve and stimulation properties in cochlear implant (CI) users. However, ECAP detection can be difficult and very subjective at near-threshold stimulation levels or in spread of excitation measurements. In this study, we evaluated the statistical properties of the background noise (BN) and the postaverage residual noise (RN) in ECAP measurements in order to determine an objective detection criterion. For the estimation of the BN and the RN, a method currently used in auditory brainstem response measurements was applied. The potential benefit of using weighted (Bayesian) averages was also examined. All estimations were performed with a set of approximately 360 ECAP measurements recorded from five human CI users of the CII or HiRes90K device (advanced bionics). Results demonstrated that the BN was normally distributed and the RN decreased according to the square root of the number of averages. No additional benefit was observed by using weighted averaging. The noise was not significantly different either at different stimulation intensities or across recording electrodes along the cochlea. The analysis of the statistical properties of the noise indicated that a signal-to-noise ratio of 1.7 dB as a detection criterion corresponds to a false positive detection rate of 1% with the used measurement setup.

Entities:  

Mesh:

Year:  2012        PMID: 22510942     DOI: 10.1109/TBME.2012.2194292

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  Excitation Patterns of Standard and Steered Partial Tripolar Stimuli in Cochlear Implants.

Authors:  Ching-Chih Wu; Xin Luo
Journal:  J Assoc Res Otolaryngol       Date:  2015-12-21

Review 2.  The Panoramic ECAP Method: Estimating Patient-Specific Patterns of Current Spread and Neural Health in Cochlear Implant Users.

Authors:  Charlotte Garcia; Tobias Goehring; Stefano Cosentino; Richard E Turner; John M Deeks; Tim Brochier; Taren Rughooputh; Manohar Bance; Robert P Carlyon
Journal:  J Assoc Res Otolaryngol       Date:  2021-04-23

3.  Optimized SNR-based ECAP threshold determination is comparable to the judgement of human evaluators.

Authors:  Lutz Gärtner; Philipp Spitzer; Kathrin Lauss; Marko Takanen; Thomas Lenarz; Sebastian Hoth
Journal:  PLoS One       Date:  2021-11-01       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.