| Literature DB >> 22509120 |
Gislaine Cristine Martins1, Alfonso Sánchez-Ayala, Paulo Henrique Perlatti D'Alpino, Abraham Lincoln Calixto, João Carlos Gomes, Osnara Maria Mongruel Gomes.
Abstract
OBJECTIVE: To evaluate the effect of thermo-mechanical cycling (TMC) on the microleakage (μL) and axial gap width (AG) of Class V bonded restorations in premolars using self-etching adhesive systems. The bond strength of composite restorations to dentin (μTBS) using the same adhesives was also evaluated in third molars after water storage: 24 h and 6 months. The research hypotheses were tested for the results of two self-etching adhesives in comparison when a conventional two-step adhesive was used: (1) the μL and AG would be lower, regardless of TMC; (2) the μTBS of self-etching adhesives would be higher, irrespective of evaluation times.Entities:
Keywords: Dentin-bonding agents; bond strength; durability; microleakage
Year: 2012 PMID: 22509120 PMCID: PMC3327497
Source DB: PubMed Journal: Eur J Dent
Composition and application mode of the materials used.
| 4BC | |||
| Apply an adequate amount of primer assuring that the total reaction time should not be shorter than 30 s. Excess primer dispersed with a strong stream of air until the mobile liquid film is no longer visible. Application of bond, beginning with the dentin tissue. Bond dispersed with a very weak stream of air. Bond photoactivated for 10 s. | J09568 | ||
| After mixing the content of the reservoirs, apply adhesive to the entire surface of the cavity, rubbing in the solution with moderate finger pressure for 15 s. Use a gentle stream of air to thoroughly dry the adhesive to a thin film. Light cure for 10 s. | 293053 |
Bis-GMA: Bisfenol-A diglicidil dimethacrylate; HEMA: 2-Hydroxyethyl methacrylate
Median of microleakage observed at dentin margins.
| 8 | 2 | 0 | 0 | 0 | ||
| 5 | 3 | 1 | 1 | 0.5 | ||
| 7 | 0 | 2 | 1 | 0 | ||
| 5 | 4 | 1 | 0 | 0.5 | ||
| 7 | 1 | 2 | 0 | 0 | ||
| 4 | 5 | 1 | 0 | 1 | ||
Figure 1.Percentage (%) of gap-free interfaces according to the experimental groups.
Adhesive axial gap width (standard deviation).
| 1,83 (2,48) | 0,69 (1,53) | 2,16 (2,71) | |
| 6,94 (9,42) | 1,63 (2,15) | 5,91 (6,98) |
ASB2: Adper Single Bond 2; ASE: AdheSE; APL-P: Adper Prompt L-Pop; Control: no treated specimens; TCM: thermo-mechanically cycled specimens n=10
All values were statistically equivalent (ANOVA test, P>.05).
Figure 2.Microtensile bond strength measured immediately and after six months. ASB2: Adper Single Bond 2, ASE: AdheSE, APL-P: Adper Prompt L-Pop. Different letters: significant (P<.05). Vertical bars represent + 1 standard deviation.