Literature DB >> 22505789

Detector Position Estimation for PET Scanners.

Larry Pierce1, Robert Miyaoka, Tom Lewellen, Adam Alessio, Paul Kinahan.   

Abstract

Physical positioning of scintillation crystal detector blocks in Positron Emission Tomography (PET) scanners is not always exact. We test a proof of concept methodology for the determination of the six degrees of freedom for detector block positioning errors by utilizing a rotating point source over stepped axial intervals. To test our method, we created computer simulations of seven Micro Crystal Element Scanner (MiCES) PET systems with randomized positioning errors. The computer simulations show that our positioning algorithm can estimate the positions of the block detectors to an average of one-seventh of the crystal pitch tangentially, and one-third of the crystal pitch axially. Virtual acquisitions of a point source grid and a distributed phantom show that our algorithm improves both the quantitative and qualitative accuracy of the reconstructed objects. We believe this estimation algorithm is a practical and accurate method for determining the spatial positions of scintillation detector blocks.

Entities:  

Year:  2012        PMID: 22505789      PMCID: PMC3324303          DOI: 10.1016/j.nima.2012.02.040

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  5 in total

1.  Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner.

Authors:  Kisung Lee; Paul E Kinahan; Jeffrey A Fessler; Robert S Miyaoka; Marie Janes; Tom K Lewellen
Journal:  Phys Med Biol       Date:  2004-10-07       Impact factor: 3.609

2.  Fabrication and characterization of a 0.5-mm lutetium oxyorthosilicate detector array for high-resolution PET applications.

Authors:  Jennifer R Stickel; Jinyi Qi; Simon R Cherry
Journal:  J Nucl Med       Date:  2007-01       Impact factor: 10.057

3.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

4.  Treatment of axial data in three-dimensional PET.

Authors:  M E Daube-Witherspoon; G Muehllehner
Journal:  J Nucl Med       Date:  1987-11       Impact factor: 10.057

5.  Development of a single detector ring micro crystal element scanner: QuickPET II.

Authors:  Robert S Miyaoka; Marie L Janes; Kisung Lee; Byungki Park; Paul E Kinahan; Tom K Lewellen
Journal:  Mol Imaging       Date:  2005 Apr-Jun       Impact factor: 4.488

  5 in total