Literature DB >> 22496546

Model-based noninvasive estimation of intracranial pressure from cerebral blood flow velocity and arterial pressure.

Faisal M Kashif1, George C Verghese, Vera Novak, Marek Czosnyka, Thomas Heldt.   

Abstract

Intracranial pressure (ICP) is affected in many neurological conditions. Clinical measurement of pressure on the brain currently requires placing a probe in the cerebrospinal fluid compartment, the brain tissue, or other intracranial space. This invasiveness limits the measurement to critically ill patients. Because ICP is also clinically important in conditions ranging from brain tumors and hydrocephalus to concussions, noninvasive determination of ICP would be desirable. Our model-based approach to continuous estimation and tracking of ICP uses routinely obtainable time-synchronized, noninvasive (or minimally invasive) measurements of peripheral arterial blood pressure and blood flow velocity in the middle cerebral artery (MCA), both at intra-heartbeat resolution. A physiological model of cerebrovascular dynamics provides mathematical constraints that relate the measured waveforms to ICP. Our algorithm produces patient-specific ICP estimates with no calibration or training. Using 35 hours of data from 37 patients with traumatic brain injury, we generated ICP estimates on 2665 nonoverlapping 60-beat data windows. Referenced against concurrently recorded invasive parenchymal ICP that varied over 100 millimeters of mercury (mmHg) across all records, our estimates achieved a mean error (bias) of 1.6 mmHg and SD of error (SDE) of 7.6 mmHg. For the 1673 data windows over 22 hours in which blood flow velocity recordings were available from both the left and the right MCA, averaging the resulting bilateral ICP estimates reduced the bias to 1.5 mmHg and SDE to 5.9 mmHg. This accuracy is already comparable to that of some invasive ICP measurement methods in current clinical use.

Entities:  

Mesh:

Year:  2012        PMID: 22496546      PMCID: PMC4010388          DOI: 10.1126/scitranslmed.3003249

Source DB:  PubMed          Journal:  Sci Transl Med        ISSN: 1946-6234            Impact factor:   17.956


  39 in total

1.  Continuous recording and control of ventricular fluid pressure in neurosurgical practice.

Authors:  N LUNDBERG
Journal:  Acta Psychiatr Scand Suppl       Date:  1960

2.  Plateau-wave phenomenon (I). Correlation between the appearance of plateau waves and CSF circulation in patients with intracranial hypertension.

Authors:  M Hayashi; Y Handa; H Kobayashi; H Kawano; H Ishii; S Hirose
Journal:  Brain       Date:  1991-12       Impact factor: 13.501

Review 3.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

Review 4.  A review of physiological simulation models of intracranial pressure dynamics.

Authors:  Wayne Wakeland; Brahm Goldstein
Journal:  Comput Biol Med       Date:  2008-08-29       Impact factor: 4.589

5.  Noninvasive measurement of pulsatile intracranial pressure using ultrasound.

Authors:  T Ueno; R E Ballard; L M Shuer; J H Cantrell; W T Yost; A R Hargens
Journal:  Acta Neurochir Suppl       Date:  1998

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Methods of experimental and clinical assessment of the relative measurement accuracy of an intracranial pressure transducer. Technical note.

Authors:  M H Morgalla; L Krasznai; K Dietz; H Mettenleiter; M Deininger; E H Grote
Journal:  J Neurosurg       Date:  2001-09       Impact factor: 5.115

Review 8.  Contribution of mathematical modelling to the interpretation of bedside tests of cerebrovascular autoregulation.

Authors:  M Czosnyka; S Piechnik; H K Richards; P Kirkpatrick; P Smielewski; J D Pickard
Journal:  J Neurol Neurosurg Psychiatry       Date:  1997-12       Impact factor: 10.154

Review 9.  Traumatic cerebral vascular injury: the effects of concussive brain injury on the cerebral vasculature.

Authors:  Douglas S DeWitt; Donald S Prough
Journal:  J Neurotrauma       Date:  2003-09       Impact factor: 5.269

Review 10.  Monitoring of cerebrovascular autoregulation: facts, myths, and missing links.

Authors:  Marek Czosnyka; Ken Brady; Matthias Reinhard; Piotr Smielewski; Luzius A Steiner
Journal:  Neurocrit Care       Date:  2009-01-06       Impact factor: 3.210

View more
  21 in total

1.  Reliable Collection of Real-Time Patient Physiologic Data from less Reliable Networks: a "Monitor of Monitors" System (MoMs).

Authors:  Peter F Hu; Shiming Yang; Hsiao-Chi Li; Lynn G Stansbury; Fan Yang; George Hagegeorge; Catriona Miller; Peter Rock; Deborah M Stein; Colin F Mackenzie
Journal:  J Med Syst       Date:  2016-11-05       Impact factor: 4.460

Review 2.  Informatics for neurocritical care: challenges and opportunities.

Authors:  Ahilan Sivaganesan; Geoffrey T Manley; Michael C Huang
Journal:  Neurocrit Care       Date:  2014-02       Impact factor: 3.210

3.  Transcranial Doppler as a non-invasive method to estimate cerebral perfusion pressure in children with severe traumatic brain injury.

Authors:  Francisco Abecasis; Danilo Cardim; Marek Czosnyka; Chiara Robba; Shruti Agrawal
Journal:  Childs Nerv Syst       Date:  2019-07-04       Impact factor: 1.475

4.  [Non-invasive estimation of intracranial pressure : MR-based evaluation in children with hydrocephalus].

Authors:  M Muehlmann; D Steffinger; A Peraud; M Lehner; F Heinen; N Alperin; B Ertl-Wagner; I K Koerte
Journal:  Radiologe       Date:  2012-09       Impact factor: 0.635

5.  Can intracranial pressure be measured non-invasively bedside using a two-depth Doppler-technique?

Authors:  Lars-Owe D Koskinen; Jan Malm; Rolandas Zakelis; Laimonas Bartusis; Arminas Ragauskas; Anders Eklund
Journal:  J Clin Monit Comput       Date:  2016-03-14       Impact factor: 2.502

6.  An integrative model of the cardiovascular system coupling heart cellular mechanics with arterial network hemodynamics.

Authors:  Young-Tae Kim; Jeong Sang Lee; Chan-Hyun Youn; Jae-Sung Choi; Eun Bo Shim
Journal:  J Korean Med Sci       Date:  2013-07-31       Impact factor: 2.153

7.  Non-invasive detection of intracranial hypertension using a simplified intracranial hemo- and hydro-dynamics model.

Authors:  Kwang Jin Lee; Chanki Park; Jooyoung Oh; Boreom Lee
Journal:  Biomed Eng Online       Date:  2015-05-30       Impact factor: 2.819

8.  Assessment of non-invasive ICP during CSF infusion test: an approach with transcranial Doppler.

Authors:  D Cardim; M Czosnyka; J Donnelly; C Robba; B C T Cabella; X Liu; M T Cabeleira; P Smielewsky; C Haubrich; M R Garnett; J D Pickard; Z Czosnyka
Journal:  Acta Neurochir (Wien)       Date:  2015-12-23       Impact factor: 2.216

9.  Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods.

Authors:  Danilo Cardim; Chiara Robba; Joseph Donnelly; Michal Bohdanowicz; Bernhard Schmidt; Maxwell Damian; Georgios V Varsos; Xiuyun Liu; Manuel Cabeleira; Gustavo Frigieri; Brenno Cabella; Peter Smielewski; Sergio Mascarenhas; Marek Czosnyka
Journal:  J Neurotrauma       Date:  2015-12-17       Impact factor: 5.269

10.  Artifact rejection and missing data imputation in cerebral blood flow velocity signals via trace norm minimization.

Authors:  Cameron Allan Gunn; Xiao Hu; Lieven Vandenberghe
Journal:  Physiol Meas       Date:  2020-12-11       Impact factor: 2.833

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.