Literature DB >> 22495959

[Microscope-integrated intraoperative indocyanine green angiography in plastic surgery].

T Holzbach1, N Artunian, T A Spanholtz, E Volkmer, T O Engelhardt, R E Giunta.   

Abstract

The knowledge of tissue perfusion has not only a prognostic value in microvascular surgery but also the intraoperative detection of malperfusion can lead to a quick surgical intervention. Indocyanine green (ICG) angiography allows a topographic analysis of perfusion and is used to assess lymphatic drainage pathways and to analyse the depth of burn injuries. Integrating the technique into an operating microscope enables visualisation of the flow over microanastomoses and allows the assessment of the transit time of blood flow between arterial and venous anastomosis. Using this method we analysed 11 microsurgical free flaps (3 latissimus dorsi, 3 rectus abdominis, 1 gracilis muscle, 2 radial forearm, 1 ALT, and 1 DIEP flap). The topographic analysis was performed after the assessment of the microanastomoses. We observed no flap loss or partial flap necrosis. The transit time between arterial inflow and venous outflow was 32.8 s on average. Here we observed distinct differences between muscle flaps (27.7 s) on the one hand and fasciocutaneous and perforator flaps (47.5 s) on the other hand. We detected one venous thrombosis by ICG angiography in a case where the clinical patency test was not distinct. Revision was performed immediately. Particularly for intraoperative assessment, ICG angiography is a useful, reliable and safe technique. The integration into the operating microscope allows an "angiographic patency test" and the analysis of the transit time allows the evaluation of blood flow within the flap. Especially when planning perforator flaps the method of ICG angiography provides a new level of safety in flap design by quickly demonstrating the borders of perfusion. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22495959     DOI: 10.1055/s-0032-1309023

Source DB:  PubMed          Journal:  Handchir Mikrochir Plast Chir        ISSN: 0722-1819            Impact factor:   1.018


  5 in total

1.  Comprehensive review of surgical microscopes: technology development and medical applications.

Authors:  Ling Ma; Baowei Fei
Journal:  J Biomed Opt       Date:  2021-01       Impact factor: 3.170

2.  Arteriovenous Loops Enable Free Tissue Transfer With Otherwise Inadequate Local Donor and Recipient Vessels.

Authors:  Mathias Tremp; Carlo M Oranges; Thomas Wolff; Marina Barandun; Ilario Fulco; Henrik Eckardt; Dirk J Schaefer; Daniel F Kalbermatten
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

3.  Role of Indocyanine Green in Fluorescence Imaging with Near-Infrared Light to Identify Sentinel Lymph Nodes, Lymphatic Vessels and Pathways Prior to Surgery - A Critical Evaluation of Options.

Authors:  Andreas Hackethal; Markus Hirschburger; Sven Oliver Eicker; Thomas Mücke; Christoph Lindner; Olaf Buchweitz
Journal:  Geburtshilfe Frauenheilkd       Date:  2018-01-22       Impact factor: 2.915

4.  Evaluation of the Intraoperative Blood Flow of Pedicled Perforator Flaps Using Indocyanine Green-fluorescence Angiography.

Authors:  Rafael G Jakubietz; Karsten Schmidt; Silvia Bernuth; Rainer H Meffert; Michael G Jakubietz
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-09-30

5.  Intraoperative Blood Flow Analysis of DIEP vs. ms-TRAM Flap Breast Reconstruction Combining Transit-Time Flowmetry and Microvascular Indocyanine Green Angiography.

Authors:  Alexander Geierlehner; Raymund E Horch; Ingo Ludolph; Andreas Arkudas
Journal:  J Pers Med       Date:  2022-03-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.