Literature DB >> 22494894

Neutron and photon spectra in LINACs.

H R Vega-Carrillo1, S A Martínez-Ovalle, A M Lallena, G A Mercado, J L Benites-Rengifo.   

Abstract

A Monte Carlo calculation, using the MCNPX code, was carried out in order to estimate the photon and neutron spectra in two locations of two linacs operating at 15 and 18 MV. Detailed models of both linac heads were used in the calculations. Spectra were estimated below the flattening filter and at the isocenter. Neutron spectra show two components due to evaporation and knock-on neutrons. Lethargy spectra under the filter were compared to the spectra calculated from the function quoted by Tosi et al. that describes reasonably well neutron spectra beyond 1 MeV, though tends to underestimate the energy region between 10(-6) and 1 MeV. Neutron and the Bremsstrahlung spectra show the same features regardless of the linac voltage.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22494894     DOI: 10.1016/j.apradiso.2012.03.034

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  6 in total

1.  Application of the phase-space distribution approach of Monte Carlo for radiation contamination dose estimation from the (n,γ), (γ,n) nuclear reactions and linac leakage photons in the megavoltage radiotherapy facility.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-24

2.  Neutron and high energy photon fluence estimation in CLINAC using gold activation foils.

Authors:  Kh Haddad; O Anjak; B Yousef
Journal:  Rep Pract Oncol Radiother       Date:  2018-10-11

3.  Dosimetric algorithm to reproduce isodose curves obtained from a LINAC.

Authors:  Julio Cesar Estrada Espinosa; Segundo Agustín Martínez Ovalle; Cinthia Kotzian Pereira Benavides
Journal:  Comput Math Methods Med       Date:  2014-06-18       Impact factor: 2.238

4.  Study of Photoneutron Production for the 18 MV Photon Beam of the Siemens Medical linac by Monte Carlo Simulation.

Authors:  Dowlatabadi H; Mowlavi A A; Ghorbani M; Mohammadi S; Knaup C
Journal:  J Biomed Phys Eng       Date:  2020-12-01

5.  Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams.

Authors:  H Dowlatabadi; A A Mowlavi; M Ghorbani
Journal:  J Biomed Phys Eng       Date:  2017-12-01

6.  Benchmarking of Siemens Linac in Electron Modes: 8-14 MeV Electron Beams.

Authors:  H Dowlatabadi; A A Mowlavi; M Ghorbani; S Mohammadi; F Akbari
Journal:  J Biomed Phys Eng       Date:  2018-06-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.