Literature DB >> 22494114

Ultra-low flow electrospray ionization-mass spectrometry for improved ionization efficiency in phosphoproteomics.

Anthonius A M Heemskerk1, Jean-Marc Busnel, Bart Schoenmaker, Rico J E Derks, Oleg Klychnikov, Paul J Hensbergen, André M Deelder, Oleg A Mayboroda.   

Abstract

The potential benefits of ultra-low flow electrospray ionization (ESI) for the analysis of phosphopeptides in proteomics was investigated. First, the relative flow dependent ionization efficiency of nonphosphorylated vs multiplyphosphorylated peptides was characterized by infusion of a five synthetic peptide mix with zero to four phophorylation sites at flow rates ranging from 4.5 to 500 nL/min. Most importantly, similar to what was found earlier by Schmidt et al., it has been verified that at flow rates below 20 nL/min the relative peak intensities for the various peptides show a trend toward an equimolar response, which would be highly beneficial in phosphoproteomic analysis. As the technology to achieve liquid chromatography separation at flow rates below 20 nL/min is not readily available, a sheathless capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) strategy based on the use of a neutrally coated separation capillary was used to develop an analytical strategy at flow rates as low as 6.6 nL/min. An in-line preconcentration technique, namely, transient isotachophoresis (t-ITP), to achieve efficient separation while using larger volume injections (37% of capillary thus 250 nL) was incorporated to achieve even greater sample concentration sensitivities. The developed t-ITP-ESI-MS strategy was then used in a direct comparison with nano-LC-MS for the detection of phosphopeptides. The comparison showed significantly improved phosphopeptide sensitivity in equal sample load and equal sample concentration conditions for CE-MS while providing complementary data to LC-MS, demonstrating the potential of ultra-low flow ESI for the analysis of phosphopeptides in liquid based separation techniques.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22494114     DOI: 10.1021/ac300641x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  17 in total

Review 1.  Recent advances in enrichment and separation strategies for mass spectrometry-based phosphoproteomics.

Authors:  Chenxi Yang; Xuefei Zhong; Lingjun Li
Journal:  Electrophoresis       Date:  2014-06-16       Impact factor: 3.535

Review 2.  Recent advances in coupling capillary electrophoresis-based separation techniques to ESI and MALDI-MS.

Authors:  Xuefei Zhong; Zichuan Zhang; Shan Jiang; Lingjun Li
Journal:  Electrophoresis       Date:  2013-12-05       Impact factor: 3.535

3.  Picoelectrospray ionization mass spectrometry using narrow-bore chemically etched emitters.

Authors:  Ioan Marginean; Keqi Tang; Richard D Smith; Ryan T Kelly
Journal:  J Am Soc Mass Spectrom       Date:  2014-01       Impact factor: 3.109

4.  On the ionization and ion transmission efficiencies of different ESI-MS interfaces.

Authors:  Jonathan T Cox; Ioan Marginean; Richard D Smith; Keqi Tang
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-30       Impact factor: 3.109

Review 5.  Protein analysis by shotgun/bottom-up proteomics.

Authors:  Yaoyang Zhang; Bryan R Fonslow; Bing Shan; Moon-Chang Baek; John R Yates
Journal:  Chem Rev       Date:  2013-02-26       Impact factor: 60.622

6.  Ultrasensitive sample quantitation via selected reaction monitoring using CITP/CZE-ESI-triple quadrupole MS.

Authors:  Chenchen Wang; Cheng S Lee; Richard D Smith; Keqi Tang
Journal:  Anal Chem       Date:  2012-11-20       Impact factor: 6.986

7.  Improvement of Mitochondria Extract from Saccharomyces cerevisiae Characterization in Shotgun Proteomics Using Sheathless Capillary Electrophoresis Coupled to Tandem Mass Spectrometry.

Authors:  Marianne Ibrahim; Rabah Gahoual; Ludovic Enkler; Hubert Dominique Becker; Johana Chicher; Philippe Hammann; Yannis-Nicolas François; Lauriane Kuhn; Emmanuelle Leize-Wagner
Journal:  J Chromatogr Sci       Date:  2016-02-08       Impact factor: 1.618

8.  Rapid preconcentration for liquid chromatography-mass spectrometry assay of trace level neuropeptides.

Authors:  Ying Zhou; Omar S Mabrouk; Robert T Kennedy
Journal:  J Am Soc Mass Spectrom       Date:  2013-04-17       Impact factor: 3.109

9.  Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis.

Authors:  Yueju Wang; Bryan R Fonslow; Catherine C L Wong; Aleksey Nakorchevsky; John R Yates
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

10.  Capillary isotachophoresis-nanoelectrospray ionization-selected reaction monitoring MS via a novel sheathless interface for high sensitivity sample quantification.

Authors:  Chenchen Wang; Cheng S Lee; Richard D Smith; Keqi Tang
Journal:  Anal Chem       Date:  2013-07-08       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.