Literature DB >> 2248827

Non-invasive monitoring of finger arterial pressure in patients with Raynaud's phenomenon: effects of exposure to cold.

T S Kurki1, H I Piirainen, P T Kurki.   

Abstract

We studied the effects of exposure to cold on finger arterial pressure (FAP) measured by a finger arterial pressure monitor in 15 patients with Raynaud's phenomenon and in 15 healthy volunteers. The cold exposure induced vasoconstriction of the peripheral vascular bed as judged by the plethysmograph of a pulse oximeter and had marked effects on FAP values compared with upper arm arterial pressure. Immediately after the cold exposure, FAP decreased significantly (P less than or equal to 0.01) in both groups. However, during the subsequent 20 min, FAP values increased in relation to upper arm pressure. Finally, FAP values were greater than upper arm pressure in the control individuals, but not in patients with Raynaud's phenomenon. These results have implications for non-invasive monitoring of arterial pressure by the finger pressure device. Clinically, significant problems may arise in the monitoring of FAP in patients with a systemic connective tissue disease affecting peripheral circulation.

Entities:  

Mesh:

Year:  1990        PMID: 2248827     DOI: 10.1093/bja/65.4.558

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  6 in total

1.  Continuous mean arterial pressure measurement in the fingers: the influence of local arm cooling.

Authors:  R Raamat; K Jagomägi; J Talts; E Länsimies; J Jurvelin; P Kolari
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  Development of noninvasive measurement of peripheral circulation and its medical application.

Authors:  H Nakamura
Journal:  Environ Health Prev Med       Date:  1997-04       Impact factor: 3.674

3.  The effect of blood pressure calibrations and transcranial Doppler signal loss on transfer function estimates of cerebral autoregulation.

Authors:  Brian M Deegan; Jorge M Serrador; Kazuma Nakagawa; Edward Jones; Farzaneh A Sorond; Gearóid Olaighin
Journal:  Med Eng Phys       Date:  2011-01-15       Impact factor: 2.242

4.  Non-invasive continuous blood pressure monitoring of tachycardic episodes during interventional electrophysiology.

Authors:  Roberto Maggi; Valentina Viscardi; Toshiyuki Furukawa; Michele Brignole
Journal:  Europace       Date:  2010-09-13       Impact factor: 5.214

5.  Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

Authors:  Andrea Casati; Grazia Squicciarini; Marco Baciarello; Marta Putzu; Alessandra Salvadori; Guido Fanelli
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

6.  Impact and management of physiological calibration in spectral analysis of blood pressure variability.

Authors:  Antti M Kiviniemi; Heidi Hintsala; Arto J Hautala; Tiina M Ikäheimo; Jouni J Jaakkola; Suvi Tiinanen; Tapio Seppänen; Mikko P Tulppo
Journal:  Front Physiol       Date:  2014-12-03       Impact factor: 4.566

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.