Literature DB >> 22481813

Spatial resolution properties of motion-compensated tomographic image reconstruction methods.

Se Young Chun1, Jeffrey A Fessler.   

Abstract

Many motion-compensated image reconstruction (MCIR) methods have been proposed to correct for subject motion in medical imaging. MCIR methods incorporate motion models to improve image quality by reducing motion artifacts and noise. This paper analyzes the spatial resolution properties of MCIR methods and shows that nonrigid local motion can lead to nonuniform and anisotropic spatial resolution for conventional quadratic regularizers. This undesirable property is akin to the known effects of interactions between heteroscedastic log-likelihoods (e.g., Poisson likelihood) and quadratic regularizers. This effect may lead to quantification errors in small or narrow structures (such as small lesions or rings) of reconstructed images. This paper proposes novel spatial regularization design methods for three different MCIR methods that account for known nonrigid motion. We develop MCIR regularization designs that provide approximately uniform and isotropic spatial resolution and that match a user-specified target spatial resolution. Two-dimensional PET simulations demonstrate the performance and benefits of the proposed spatial regularization design methods.

Entities:  

Mesh:

Year:  2012        PMID: 22481813      PMCID: PMC3389228          DOI: 10.1109/TMI.2012.2192133

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  31 in total

1.  A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution.

Authors:  Johan Nuyts; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-09       Impact factor: 10.048

2.  Model-based image reconstruction for four-dimensional PET.

Authors:  Tianfang Li; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Lei Xing
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

3.  Myocardial motion analysis from B-mode echocardiograms.

Authors:  Michael Sühling; Muthuvel Arigovindan; Christian Jansen; Patrick Hunziker; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2005-04       Impact factor: 10.856

4.  Analysis of Resolution and Noise Properties of Nonquadratically Regularized Image Reconstruction Methods for PET.

Authors:  Sangtae Ahn; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2008-03       Impact factor: 10.048

5.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

Review 6.  Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

Authors:  Matthias Hofmann; Bernd Pichler; Bernhard Schölkopf; Thomas Beyer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

7.  Regularized B-spline deformable registration for respiratory motion correction in PET images.

Authors:  Wenjia Bai; Michael Brady
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

8.  A novel algorithm for heart motion analysis based on geometric constraints.

Authors:  Mingxing Hu; Graeme Penney; Daniel Rueckert; Philip Edwards; Michael Figl; Philip Pratt; David Hawkes
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

9.  A simple regularizer for B-spline nonrigid image registration that encourages local invertibility.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE J Sel Top Signal Process       Date:  2009-02-01       Impact factor: 6.856

10.  Quadratic regularization design for 2-D CT.

Authors:  Hugo R Shi; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2008-10-31       Impact factor: 10.048

View more
  7 in total

Review 1.  The Use of Anatomical Information for Molecular Image Reconstruction Algorithms: Attenuation/Scatter Correction, Motion Compensation, and Noise Reduction.

Authors:  Se Young Chun
Journal:  Nucl Med Mol Imaging       Date:  2016-02-11

2.  Pulmonary imaging using respiratory motion compensated simultaneous PET/MR.

Authors:  Joyita Dutta; Chuan Huang; Quanzheng Li; Georges El Fakhri
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

3.  Alternating direction method of multiplier for tomography with nonlocal regularizers.

Authors:  Se Young Chun; Yuni K Dewaraja; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10       Impact factor: 10.048

4.  Noise properties of motion-compensated tomographic image reconstruction methods.

Authors:  Se Young Chun; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2012-06-29       Impact factor: 10.048

Review 5.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

6.  General simultaneous motion estimation and image reconstruction (G-SMEIR).

Authors:  Shiwei Zhou; Yujie Chi; Jing Wang; Mingwu Jin
Journal:  Biomed Phys Eng Express       Date:  2021-07-29

Review 7.  Quantitative statistical methods for image quality assessment.

Authors:  Joyita Dutta; Sangtae Ahn; Quanzheng Li
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.