Literature DB >> 22476524

Femoro-tibial kinematics after TKA in fixed- and mobile-bearing knees in the sagittal plane.

Kiriakos Daniilidis1, Steffen Höll, Georg Gosheger, Ralf Dieckmann, Nicolo Martinelli, Sven Ostermeier, Carsten O Tibesku.   

Abstract

PURPOSE: Lack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile-bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed- and mobile-bearing TKA in comparison with the natural knee joint.
METHODS: Seven knee joints of human cadaver material were used in a laboratory experiment. Fixed- and mobile-bearing inlays were tested in sequences under isokinetic extension in so-called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio-femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control.
RESULTS: The results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z-axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile-bearing" and "fixed-bearing" prostheses.
CONCLUSION: Results of this study cannot prove functional advantages of mobile-bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.

Entities:  

Mesh:

Year:  2012        PMID: 22476524     DOI: 10.1007/s00167-012-1986-6

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  29 in total

1.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

2.  The kinematics of fixed- and mobile-bearing total knee arthroplasty.

Authors:  Ephrat Most; Guoan Li; Steven Schule; Peter Sultan; Sang Eun Park; Shay Zayontz; Harry E Rubash
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

3.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

4.  Mobile-bearing prosthesis did not improve mid-term clinical results of total knee arthroplasty.

Authors:  Shuichi Matsuda; Hideki Mizu-uchi; Shingo Fukagawa; Hiromasa Miura; Ken Okazaki; Hideo Matsuda; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-21       Impact factor: 4.342

5.  In vitro kinematic measurements of the patellar tendon in two different types of posterior-stabilized total knee arthroplasties.

Authors:  Zhonglin Zhu; Hui Ding; Xiao Dang; Jing Tang; Yixin Zhou; Guangzhi Wang
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

6.  Dynamic in vitro measurement of posterior cruciate ligament load and tibiofemoral stress after TKA in dependence on tibiofemoral slope.

Authors:  Sven Ostermeier; Christoph Schlomach; Christof Hurschler; Henning Windhagen; Christina Stukenborg-Colsman
Journal:  Clin Biomech (Bristol, Avon)       Date:  2006-02-21       Impact factor: 2.063

7.  Changes in knee kinematics reflect the articular geometry after arthroplasty.

Authors:  Anthony M J Bull; Oliver Kessler; Mahbub Alam; Andrew A Amis
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

Review 8.  Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis.

Authors:  Toby O Smith; Farshid Ejtehadi; Rachel Nichols; Leigh Davies; Simon T Donell; Caroline B Hing
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-25       Impact factor: 4.342

9.  Relative motion of a mobile bearing inlay after total knee arthroplasty--dynamic in vitro study.

Authors:  C Stukenborg-Colsman; S Ostermeier; K H Wenger; C J Wirth
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-01       Impact factor: 2.063

10.  Modification of the posterior cruciate ligament tension following total knee arthroplasty: comparison of the Genesis CR and LCS meniscal bearing prostheses.

Authors:  Thomas Siebel; Wolfram Käfer
Journal:  Knee       Date:  2004-06       Impact factor: 2.199

View more
  3 in total

1.  Deep-dished highly congruent tibial insert in CR-TKA does not prevent patellar tendon angle increase and patellar anterior translation.

Authors:  Ibrahim Akkawi; Francesca Colle; Danilo Bruni; Giovanni Francesco Raspugli; Simone Bignozzi; Stefano Zaffagnini; Francesco Iacono; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-12       Impact factor: 4.342

2.  Bicompartmental, medial and patellofemoral knee replacement might be able to maintain unloaded knee kinematics.

Authors:  Daiwei Yao; Imran Akram; Kiriakos Daniilidis; Luc Labey; Bernardo Innocenti; Carsten Tibesku
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-12       Impact factor: 3.067

3.  Total knee arthroplasty with mobile tibial weight-bearing: clinical evaluation after a minimum of five years of postoperative follow-up.

Authors:  Luiz Gabriel Betoni Guglielmetti; Pedro Pereira da Costa; Ricardo de Paula Leite Cury; Victor Marques de Oliveira; Nilson Roberto Severino; Osmar Pedro Arbix de Camargo
Journal:  Rev Bras Ortop       Date:  2015-05-30
  3 in total