Literature DB >> 22476342

[Hardware removal after pelvic ring injury].

F M Stuby1, C E Gonser, H C Baron, U Stöckle, A Badke, B G Ochs.   

Abstract

BACKGROUND: Pelvic ring fractures are considered as rare injuries. Minimally invasive sacroiliac screw fixation has been used increasingly in recent years as an operative strategy for the treatment of these injuries, if the dorsal pelvic ring needed to be addressed. Treatment options for the anterior pelvic ring comprise plates, screws or external fixation.
METHOD: Based on the limited number of publications on this subject and our own experience with 80 patients who suffered pelvic ring B- or C-type injuries during a period of 8 years we are able to show that the indication for hardware removal in the pelvic ring should be strictly defined.
RESULTS: In some cases like external fixation, implant-associated infection, malpositioning, allergic implant reaction, critical soft tissue covering, palpable hardware and consolidated juvenile fractures implant removal is certainly indicated. In patients without symptoms and in patients with trauma-associated symptoms which are not definitely associated with the hardware, the removal should be only indicated after thorough consideration of the risks versus the benefits and additionally by taking the initial injury pattern into account. If despite all these objections the hardware removal has been indicated it should always be considered that hardware removal may be challenging with several possible severe complications.

Entities:  

Mesh:

Year:  2012        PMID: 22476342     DOI: 10.1007/s00113-012-2157-4

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  28 in total

Review 1.  Implant retention and removal after internal fixation of the symphysis pubis.

Authors:  Raghu Raman; Craig S Roberts; Hans-Christoph Pape; Peter V Giannoudis
Journal:  Injury       Date:  2005-02-25       Impact factor: 2.586

2.  Removal of an iliosacral screw entrapping the L5 nerve root after failed posterior pelvic ring fixation: a case report.

Authors:  Yoram A Weil; Markku T Nousiainen; David L Helfet
Journal:  J Orthop Trauma       Date:  2007-07       Impact factor: 2.512

3.  Movement of the human pelvis and displacement of related anatomical landmarks on the body surface.

Authors:  B Drerup; E Hierholzer
Journal:  J Biomech       Date:  1987       Impact factor: 2.712

4.  Vehicle entrapment rescue and pre-hospital trauma care.

Authors:  A B Wilmink; G S Samra; L M Watson; A W Wilson
Journal:  Injury       Date:  1996-01       Impact factor: 2.586

5.  Acute Pelvic Fractures: I. Causation and Classification.

Authors: 
Journal:  J Am Acad Orthop Surg       Date:  1996-05       Impact factor: 3.020

Review 6.  Unstable pelvic ring disruptions in unstable patients.

Authors:  P J Kregor; M L Routt
Journal:  Injury       Date:  1999       Impact factor: 2.586

7.  Epidemiology of pelvic fractures in a Swedish county.

Authors:  B Ragnarsson; B Jacobsson
Journal:  Acta Orthop Scand       Date:  1992-06

8.  [Prospective study of the significance of contact sensitization caused by metal implants].

Authors:  H W Duchna; U Nowack; R Merget; G Muhr; G Schultze-Werninghaus
Journal:  Zentralbl Chir       Date:  1998       Impact factor: 0.942

9.  Comparative radiographic and clinical outcome of two-hole and multi-hole symphyseal plating.

Authors:  H Claude Sagi; Steve Papp
Journal:  J Orthop Trauma       Date:  2008-07       Impact factor: 2.512

10.  Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.

Authors:  T A Schildhauer; C Josten; G Muhr
Journal:  J Orthop Trauma       Date:  1998 Jun-Jul       Impact factor: 2.512

View more
  2 in total

1.  Endoscopically assisted implant removal of a symphyseal pelvic plate - A case report.

Authors:  Stephan Regenbogen; Markus Beck; Michael Lang; Markus A Küper; Fabian M Stuby; Alexander Trulson
Journal:  Trauma Case Rep       Date:  2021-09-11

2.  Metal implant removal: benefits and drawbacks--a patient survey.

Authors:  Georg Reith; Vera Schmitz-Greven; Kai O Hensel; Marco M Schneider; Tibor Tinschmann; Bertil Bouillon; Christian Probst
Journal:  BMC Surg       Date:  2015-08-07       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.