Literature DB >> 22471825

Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs.

Morena B Wernick1, Robert M Höpfner, Thierry Francey, Judith Howard.   

Abstract

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO).
RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.

Entities:  

Mesh:

Year:  2012        PMID: 22471825     DOI: 10.2460/javma.240.8.962

Source DB:  PubMed          Journal:  J Am Vet Med Assoc        ISSN: 0003-1488            Impact factor:   1.936


  8 in total

1.  Oscillometric and Doppler arterial blood pressure measurement in conscious goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Anna Świerk; Oktawia Szpinda; Magdalena Garncarz; Marcin Mickiewicz; Agata Moroz; Emilia Bagnicka; Jarosław Kaba
Journal:  Can J Vet Res       Date:  2018-10       Impact factor: 1.310

2.  Effects of various factors on Doppler flow ultrasonic radial and coccygeal artery systolic blood pressure measurements in privately-owned, conscious dogs.

Authors:  Allison P Mooney; Dianne I Mawby; Joshua M Price; Jacqueline C Whittemore
Journal:  PeerJ       Date:  2017-03-22       Impact factor: 2.984

3.  Comparison of oscillometric, Doppler and invasive blood pressure measurement in anesthetized goats.

Authors:  Olga Szaluś-Jordanow; Michał Czopowicz; Agata Moroz; Marcin Mickiewicz; Magdalena Garncarz; Emilia Bagnicka; Tadeusz Frymus; Jarosław Kaba
Journal:  PLoS One       Date:  2018-05-23       Impact factor: 3.240

4.  Indirect Doppler flow systolic blood pressure measurements taken with and without headphones in privately-owned, conscious dogs.

Authors:  India R Gill; Joshua M Price; Jacqueline C Whittemore
Journal:  PeerJ       Date:  2019-08-01       Impact factor: 2.984

5.  Impact of equipment and handling on systolic blood pressure measurements in conscious dogs in an animal hospital environment.

Authors:  Maria Lyberg; Ingrid Ljungvall; Jens Häggström; Ellinor Ahlund; Lena Pelander
Journal:  J Vet Intern Med       Date:  2021-02-15       Impact factor: 3.333

6.  Comparison between the Parks Medical Doppler and the Mano Médical Vet BP Doppler for recording indirect systemic blood pressure in conscious dogs.

Authors:  Marina Domingues; Panagiotis E Archontakis; Jonathan Bouvard; Luke Winter; Danielle A Gunn-Moore
Journal:  Open Vet J       Date:  2022-08-19

7.  Comparison of forelimb and hindlimb systolic blood pressures and proteinuria in healthy Shetland Sheepdogs.

Authors:  B A Scansen; J Vitt; D J Chew; K E Schober; J D Bonagura
Journal:  J Vet Intern Med       Date:  2014-01-16       Impact factor: 3.333

8.  Effects of Toceranib Phosphate on Systolic Blood Pressure and Proteinuria in Dogs.

Authors:  S S Tjostheim; R L Stepien; L E Markovic; T J Stein
Journal:  J Vet Intern Med       Date:  2016-05-06       Impact factor: 3.333

  8 in total