Abstract

Magnetic resonance imaging (MRI) and MR arthrography have proven invaluable for managing the postoperative shoulder, particularly in relation to the rotator cuff and labrum. MRI has proven to be an accurate imaging technique for differentiating expected findings versus complications in the postoperative setting. The transition from metallic hardware to bioabsorbable suture anchors used in orthopedic surgery has rendered less metallic susceptibility artifact over the years, allowing more accurate interpretation of MR images. This article gives a pictorial review of various expected postoperative findings in the shoulder and complications related to repair of the rotator cuff and labrum.
Copyright © 2012 Elsevier Inc. All rights reserved.

Mesh:

Year:  2012        PMID: 22469406     DOI: 10.1016/j.mric.2012.01.010

Source DB:  PubMed          Journal:  Magn Reson Imaging Clin N Am        ISSN: 1064-9689            Impact factor:   2.266


  5 in total

Review 1.  [Magnetic resonance imaging findings after shoulder surgery: What the radiologist needs to know].

Authors:  U L Fahlenkamp; C Gerhardt; K-G A Hermann
Journal:  Radiologe       Date:  2017-11       Impact factor: 0.635

2.  MR arthrogram of the postoperative glenoid labrum: normal postoperative appearance versus recurrent tears.

Authors:  Christin A Tiegs-Heiden; Nicholas G Rhodes; Mark S Collins; Quintin A Fender; Benjamin M Howe
Journal:  Skeletal Radiol       Date:  2018-05-13       Impact factor: 2.199

3.  Imaging of the post-operative shoulder: does injection of iodinated contrast in addition to MR contrast during arthrography improve diagnostic accuracy and patient throughput?

Authors:  Thomas Magee
Journal:  Skeletal Radiol       Date:  2018-03-17       Impact factor: 2.199

Review 4.  Complications of rotator cuff surgery-the role of post-operative imaging in patient care.

Authors:  R S Thakkar; S C Thakkar; U Srikumaran; E G McFarland; L M Fayad
Journal:  Br J Radiol       Date:  2014-04-15       Impact factor: 3.039

5.  Metal artefacts severely hamper magnetic resonance imaging of the rotator cuff tendons after rotator cuff repair with titanium suture anchors.

Authors:  Femke F Schröder; Rianne Huis In't Veld; Lydia A den Otter; Sjoerd M van Raak; Bennie Ten Haken; Anne J H Vochteloo
Journal:  Shoulder Elbow       Date:  2017-06-05
  5 in total