Literature DB >> 22465705

An enhanced estimate of initial contact and final contact instants of time using lower trunk inertial sensor data.

John McCamley1, Marco Donati, Eleni Grimpampi, Claudia Mazzà.   

Abstract

This study introduces a new method of extracting initial and final contact gait time events from vertical acceleration, measured with one waist mounted inertial measurement unit, by means of continuous wavelet transforms. The method was validated on 18 young healthy subjects and compared to two others available in the literature. Of the three methods investigated, the new one was the most accurate at identifying the existence and timing of initial and final contacts with the ground, with an average error of 0.02±0.02 s and 0.03±0.03 s (approximately 2% and 3% of mean stride duration), respectively.
Copyright © 2012 Elsevier B.V. All rights reserved.

Mesh:

Year:  2012        PMID: 22465705     DOI: 10.1016/j.gaitpost.2012.02.019

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  59 in total

1.  Aging and the effects of a half marathon on Achilles tendon force-elongation relationship.

Authors:  Thijs Maria Anne Ackermans; Gaspar Epro; Christopher McCrum; Kai Daniel Oberländer; Frank Suhr; Maarten Robert Drost; Kenneth Meijer; Kiros Karamanidis
Journal:  Eur J Appl Physiol       Date:  2016-09-30       Impact factor: 3.078

2.  Extraction of stride events from gait accelerometry during treadmill walking.

Authors:  Ervin Sejdić; Kristin A Lowry; Jennica Bellanca; Subashan Perera; Mark S Redfern; Jennifer S Brach
Journal:  IEEE J Transl Eng Health Med       Date:  2015-12-18       Impact factor: 3.316

3.  Adaptive empirical pattern transformation (ADEPT) with application to walking stride segmentation.

Authors:  Marta Karas; Marcin Stra Czkiewicz; William Fadel; Jaroslaw Harezlak; Ciprian M Crainiceanu; Jacek K Urbanek
Journal:  Biostatistics       Date:  2021-04-10       Impact factor: 5.899

4.  Inertial Sensor-Based Centripetal Acceleration as a Correlate for Lateral Margin of Stability During Walking and Turning.

Authors:  Peter C Fino; Fay B Horak; Carolin Curtze
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2020-02-05       Impact factor: 3.802

5.  Gait event detection using inertial measurement units in people with transfemoral amputation: a comparative study.

Authors:  Emeline Simonetti; Coralie Villa; Joseph Bascou; Giuseppe Vannozzi; Elena Bergamini; Hélène Pillet
Journal:  Med Biol Eng Comput       Date:  2019-12-23       Impact factor: 2.602

Review 6.  Gait metrics analysis utilizing single-point inertial measurement units: a systematic review.

Authors:  Ralph Jasper Mobbs; Jordan Perring; Suresh Mahendra Raj; Monish Maharaj; Nicole Kah Mun Yoong; Luke Wicent Sy; Rannulu Dineth Fonseka; Pragadesh Natarajan; Wen Jie Choy
Journal:  Mhealth       Date:  2022-01-20

7.  Relationship between Tissue Gliding of the Lateral Thigh and Gait Parameters after Trochanteric Fractures.

Authors:  Kengo Kawanishi; Daisuke Fukuda; Hiroyuki Niwa; Taisuke Okuno; Toshinori Miyashita; Takashi Kitagawa; Shintarou Kudo
Journal:  Sensors (Basel)       Date:  2022-05-19       Impact factor: 3.847

Review 8.  A Systematic Review of Wearable Sensors for Monitoring Physical Activity.

Authors:  Annica Kristoffersson; Maria Lindén
Journal:  Sensors (Basel)       Date:  2022-01-12       Impact factor: 3.576

9.  Are Accelerometer-based Functional Outcome Assessments Feasible and Valid After Treatment for Lower Extremity Sarcomas?

Authors:  Sherron Furtado; Alan Godfrey; Silvia Del Din; Lynn Rochester; Craig Gerrand
Journal:  Clin Orthop Relat Res       Date:  2020-03       Impact factor: 4.755

10.  Developing Smartphone-Based Objective Assessments of Physical Function in Rheumatoid Arthritis Patients: The PARADE Study.

Authors:  Valentin Hamy; Luis Garcia-Gancedo; Andrew Pollard; Anniek Myatt; Jingshu Liu; Andrew Howland; Philip Beineke; Emilia Quattrocchi; Rachel Williams; Michelle Crouthamel
Journal:  Digit Biomark       Date:  2020-04-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.