Literature DB >> 22465078

Automatic motion compensation of free breathing acquired myocardial perfusion data by using independent component analysis.

Gert Wollny1, Peter Kellman, Andrés Santos, María J Ledesma-Carbayo.   

Abstract

Images acquired during free breathing using first-pass gadolinium-enhanced myocardial perfusion magnetic resonance imaging (MRI) exhibit a quasiperiodic motion pattern that needs to be compensated for if a further automatic analysis of the perfusion is to be executed. In this work, we present a method to compensate this movement by combining independent component analysis (ICA) and image registration: First, we use ICA and a time-frequency analysis to identify the motion and separate it from the intensity change induced by the contrast agent. Then, synthetic reference images are created by recombining all the independent components but the one related to the motion. Therefore, the resulting image series does not exhibit motion and its images have intensities similar to those of their original counterparts. Motion compensation is then achieved by using a multi-pass image registration procedure. We tested our method on 39 image series acquired from 13 patients, covering the basal, mid and apical areas of the left heart ventricle and consisting of 58 perfusion images each. We validated our method by comparing manually tracked intensity profiles of the myocardial sections to automatically generated ones before and after registration of 13 patient data sets (39 distinct slices). We compared linear, non-linear, and combined ICA based registration approaches and previously published motion compensation schemes. Considering run-time and accuracy, a two-step ICA based motion compensation scheme that first optimizes a translation and then for non-linear transformation performed best and achieves registration of the whole series in 32±12s on a recent workstation. The proposed scheme improves the Pearsons correlation coefficient between manually and automatically obtained time-intensity curves from .84±.19 before registration to .96±.06 after registration.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22465078      PMCID: PMC3372575          DOI: 10.1016/j.media.2012.02.004

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  18 in total

1.  Volume-preserving nonrigid registration of MR breast images using free-form deformation with an incompressibility constraint.

Authors:  Torsten Rohlfing; Calvin R Maurer; David A Bluemke; Michael A Jacobs
Journal:  IEEE Trans Med Imaging       Date:  2003-06       Impact factor: 10.048

2.  Improvement in the quantification of myocardial perfusion using an automatic spline-based registration algorithm.

Authors:  Christophe Dornier; Marko K Ivancevic; Philippe Thévenaz; Jean-Paul Vallée
Journal:  J Magn Reson Imaging       Date:  2003-08       Impact factor: 4.813

3.  Unsupervised motion-compensation of multi-slice cardiac perfusion MRI.

Authors:  M B Stegmann; H Olafsdóttir; H B W Larsson
Journal:  Med Image Anal       Date:  2005-08       Impact factor: 8.545

4.  Deformation-based mapping of volume change from serial brain MRI in the presence of local tissue contrast change.

Authors:  Colin Studholme; Corina Drapaca; Bistra Iordanova; Valerie Cardenas
Journal:  IEEE Trans Med Imaging       Date:  2006-05       Impact factor: 10.048

5.  Fast parametric elastic image registration.

Authors:  Jan Kybic; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

6.  First-pass myocardial perfusion image registration by maximization of normalized mutual information.

Authors:  Kelvin K Wong; Edward S Yang; Ed X Wu; Hung-Fat Tse; Stephen T Wong
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

7.  Fully automated motion correction in first-pass myocardial perfusion MR image sequences.

Authors:  Julien Milles; Rob J van der Geest; Michael Jerosch-Herold; Johan H C Reiber; Boudewijn P F Lelieveldt
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

8.  Pseudo ground truth based nonrigid registration of myocardial perfusion MRI.

Authors:  Chao Li; Ying Sun; Ping Chai
Journal:  Med Image Anal       Date:  2011-02-16       Impact factor: 8.545

9.  Exploiting quasiperiodicity in motion correction of free-breathing myocardial perfusion MRI.

Authors:  Gert Wollny; Maria J Ledesma-Carbayo; Peter Kellman; Andres Santos
Journal:  IEEE Trans Med Imaging       Date:  2010-05-03       Impact factor: 10.048

Review 10.  Quantification of myocardial perfusion by cardiovascular magnetic resonance.

Authors:  Michael Jerosch-Herold
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-08       Impact factor: 5.364

View more
  18 in total

1.  Free-breathing cardiac MR stress perfusion with real-time slice tracking.

Authors:  Tamer A Basha; Sébastien Roujol; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

2.  Noise reduction and motion elimination in low-dose 4D myocardial computed tomography perfusion (CTP): preliminary clinical evaluation of the ASTRA4D algorithm.

Authors:  Steffen Lukas; Sarah Feger; Matthias Rief; Elke Zimmermann; Marc Dewey
Journal:  Eur Radiol       Date:  2019-02-04       Impact factor: 5.315

3.  Robust Non-Rigid Motion Compensation of Free-Breathing Myocardial Perfusion MRI Data.

Authors:  Cian M Scannell; Adriana D M Villa; Jack Lee; Marcel Breeuwer; Amedeo Chiribiri
Journal:  IEEE Trans Med Imaging       Date:  2019-02-01       Impact factor: 10.048

4.  MIA - A free and open source software for gray scale medical image analysis.

Authors:  Gert Wollny; Peter Kellman; María-Jesus Ledesma-Carbayo; Matthew M Skinner; Jean-Jaques Hublin; Thomas Hierl
Journal:  Source Code Biol Med       Date:  2013-10-11

5.  Robust [Formula: see text] Approaches to Computing the Geometric Median and Principal and Independent Components.

Authors:  Stephen L Keeling; Karl Kunisch
Journal:  J Math Imaging Vis       Date:  2016-02-24       Impact factor: 1.627

6.  Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.

Authors:  Gabriele Bonanno; Allison G Hays; Robert G Weiss; Michael Schär
Journal:  Magn Reson Med       Date:  2017-12-27       Impact factor: 4.668

7.  Robust universal nonrigid motion correction framework for first-pass cardiac MR perfusion imaging.

Authors:  Mitchel Benovoy; Matthew Jacobs; Farida Cheriet; Nagib Dahdah; Andrew E Arai; Li-Yueh Hsu
Journal:  J Magn Reson Imaging       Date:  2017-02-15       Impact factor: 4.813

8.  Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI.

Authors:  Sajan Goud Lingala; Edward DiBella; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2014-07-29       Impact factor: 10.048

9.  Free-breathing, motion-corrected late gadolinium enhancement is robust and extends risk stratification to vulnerable patients.

Authors:  Kayla M Piehler; Timothy C Wong; Kathy S Puntil; Karolina M Zareba; Kathie Lin; David M Harris; Christopher R Deible; Joan M Lacomis; Ferenc Czeyda-Pommersheim; Stephen C Cook; Peter Kellman; Erik B Schelbert
Journal:  Circ Cardiovasc Imaging       Date:  2013-04-18       Impact factor: 7.792

10.  Free breathing myocardial perfusion data sets for performance analysis of motion compensation algorithms.

Authors:  Gert Wollny; Peter Kellman
Journal:  Gigascience       Date:  2014-11-11       Impact factor: 6.524

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.