Literature DB >> 18955176

Fully automated motion correction in first-pass myocardial perfusion MR image sequences.

Julien Milles1, Rob J van der Geest, Michael Jerosch-Herold, Johan H C Reiber, Boudewijn P F Lelieveldt.   

Abstract

This paper presents a novel method for registration of cardiac perfusion magnetic resonance imaging (MRI). The presented method is capable of automatically registering perfusion data, using independent component analysis (ICA) to extract physiologically relevant features together with their time-intensity behavior. A time-varying reference image mimicking intensity changes in the data of interest is computed based on the results of that ICA. This reference image is used in a two-pass registration framework. Qualitative and quantitative validation of the method is carried out using 46 clinical quality, short-axis, perfusion MR datasets comprising 100 images each. Despite varying image quality and motion patterns in the evaluation set, validation of the method showed a reduction of the average right ventricle (LV) motion from 1.26+/-0.87 to 0.64+/-0.46 pixels. Time-intensity curves are also improved after registration with an average error reduced from 2.65+/-7.89% to 0.87+/-3.88% between registered data and manual gold standard. Comparison of clinically relevant parameters computed using registered data and the manual gold standard show a good agreement. Additional tests with a simulated free-breathing protocol showed robustness against considerable deviations from a standard breathing protocol. We conclude that this fully automatic ICA-based method shows an accuracy, a robustness and a computation speed adequate for use in a clinical environment.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18955176     DOI: 10.1109/TMI.2008.928918

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  Myocardial perfusion: near-automated evaluation from contrast-enhanced MR images obtained at rest and during vasodilator stress.

Authors:  Giacomo Tarroni; Cristiana Corsi; Patrick F Antkowiak; Federico Veronesi; Christopher M Kramer; Frederick H Epstein; James Walter; Claudio Lamberti; Roberto M Lang; Victor Mor-Avi; Amit R Patel
Journal:  Radiology       Date:  2012-08-14       Impact factor: 11.105

2.  Spatiotemporal Strategies for Joint Segmentation and Motion Tracking From Cardiac Image Sequences.

Authors:  Huafeng Liu; Ting Wang; Lei Xu; Pengcheng Shi
Journal:  IEEE J Transl Eng Health Med       Date:  2017-02-23       Impact factor: 3.316

3.  Comprehensive visualization of multimodal cardiac imaging data for assessment of coronary artery disease: first clinical results of the SMARTVis tool.

Authors:  Hortense A Kirişli; V Gupta; S W Kirschbaum; A Rossi; C T Metz; M Schaap; R J van Geuns; N Mollet; B P F Lelieveldt; J H C Reiber; T van Walsum; W J Niessen
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-24       Impact factor: 2.924

4.  Robust Non-Rigid Motion Compensation of Free-Breathing Myocardial Perfusion MRI Data.

Authors:  Cian M Scannell; Adriana D M Villa; Jack Lee; Marcel Breeuwer; Amedeo Chiribiri
Journal:  IEEE Trans Med Imaging       Date:  2019-02-01       Impact factor: 10.048

5.  MIA - A free and open source software for gray scale medical image analysis.

Authors:  Gert Wollny; Peter Kellman; María-Jesus Ledesma-Carbayo; Matthew M Skinner; Jean-Jaques Hublin; Thomas Hierl
Journal:  Source Code Biol Med       Date:  2013-10-11

6.  Investigation into diagnostic accuracy of common strategies for automated perfusion motion correction.

Authors:  Constantine Zakkaroff; John D Biglands; John P Greenwood; Sven Plein; Roger D Boyle; Aleksandra Radjenovic; Derek R Magee
Journal:  J Med Imaging (Bellingham)       Date:  2016-05-13

7.  A quantitative pixel-wise measurement of myocardial blood flow by contrast-enhanced first-pass CMR perfusion imaging: microsphere validation in dogs and feasibility study in humans.

Authors:  Li-Yueh Hsu; Daniel W Groves; Anthony H Aletras; Peter Kellman; Andrew E Arai
Journal:  JACC Cardiovasc Imaging       Date:  2012-02

8.  Motion correction for myocardial T1 mapping using image registration with synthetic image estimation.

Authors:  Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

9.  Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition.

Authors:  Taehoon Shin; Krishna S Nayak; Juan M Santos; Dwight G Nishimura; Bob S Hu; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

Review 10.  Quantification in cardiac MRI: advances in image acquisition and processing.

Authors:  Anil K Attili; Andreas Schuster; Eike Nagel; Johan H C Reiber; Rob J van der Geest
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.