Literature DB >> 22464525

Dosimetry of a cone-beam computed tomography machine compared with a digital x-ray machine in orthodontic imaging.

Thorsten Grünheid1, Jacquelyn R Kolbeck Schieck, Benjamin T Pliska, Mansur Ahmad, Brent E Larson.   

Abstract

INTRODUCTION: Cone-beam computed tomography (CBCT) has become a routine imaging modality for many orthodontic clinics. However, questions remain about the amount of radiation patients are exposed to during the scans. This study determined the amounts of radiation potentially absorbed by a patient during orthodontic imaging with a CBCT machine with various scan settings compared with a conventional 2-dimensional digital x-ray machine.
METHODS: The radiation exposures delivered by a next generation i-CAT CBCT machine (Imaging Sciences International, Hatfield, Pa) at various scan settings and orthopantomograph OP100/OC100 digital x-ray machine (Instrumentarium Dental, Tuusula, Finland) during panoramic and cephalometric radiography were recorded using thermoluminescent dosimeters placed inside a head and neck phantom. The manufacturer-recommended settings for an average adult male were used for both types of machines. Effective doses were calculated using the tissue-weighting factors recommended by the 2007 International Commission on Radiological Protection.
RESULTS: The effective doses at various voxel sizes and field of view settings ranged from 64.7 to 69.2 μSv for standard resolution CBCT scans (scan time 8.9 s) and 127.3 to 131.3 μSv for high resolution full field of view scans (scan time 17.8 s), and measured 134.2 μSv for a high-resolution landscape scan with a voxel size as would be used for SureSmile (OraMetrix, Richardson, Tex) therapy (scan time 26.9 s). The effective doses for digital panoramic and lateral cephalometric radiographs measured 21.5 and 4.5 μSv, respectively.
CONCLUSIONS: CBCT, although providing additional diagnostic and therapeutic benefits, also exposes patients to higher levels of radiation than conventional digital radiography.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22464525     DOI: 10.1016/j.ajodo.2011.10.024

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  23 in total

1.  Radiation dose of cone-beam computed tomography compared to conventional radiographs in orthodontics.

Authors:  Luca Signorelli; Raphael Patcas; Timo Peltomäki; Marc Schätzle
Journal:  J Orofac Orthop       Date:  2016-01-08       Impact factor: 1.938

Review 2.  Effective dose of cone beam CT (CBCT) of the facial skeleton: a systematic review.

Authors:  A Al-Okshi; C Lindh; H Salé; M Gunnarsson; M Rohlin
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

3.  Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

Authors:  M M Lell; M S May; M Brand; A Eller; T Buder; E Hofmann; M Uder; W Wuest
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-26       Impact factor: 3.825

4.  Patient radiation dose and protection from cone-beam computed tomography.

Authors:  Gang Li
Journal:  Imaging Sci Dent       Date:  2013-06-14

5.  Age estimation for forensic purposes in Italy: ethical issues.

Authors:  Martina Focardi; Vilma Pinchi; Federica De Luca; Gian-Aristide Norelli
Journal:  Int J Legal Med       Date:  2014-03-16       Impact factor: 2.686

6.  Visibility of mandibular canal on panoramic radiograph after bilateral sagittal split osteotomy (BSSO).

Authors:  Constantinus Politis; Xiomara Botero Ramírez; Yi Sun; Ivo Lambrichts; Neil Heath; Jimoh Olubanwo Agbaje
Journal:  Surg Radiol Anat       Date:  2012-10-05       Impact factor: 1.246

7.  Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.

Authors:  John B Ludlow; Cameron Walker
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-12       Impact factor: 2.650

8.  Three-dimensional regional displacement after surgical-orthodontic correction of Class III malocclusion.

Authors:  L Koerich; A C O Ruellas; B Paniagua; M Styner; T Turvey; L H S Cevidanes
Journal:  Orthod Craniofac Res       Date:  2015-11-01       Impact factor: 1.826

Review 9.  Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units.

Authors:  J B Ludlow; R Timothy; C Walker; R Hunter; E Benavides; D B Samuelson; M J Scheske
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

10.  Ex-vivo imaging of buccal and oral periodontal bone with low-dose CBCT in porcine jaws.

Authors:  Maurice Ruetters; Holger Gehrig; Dorohtea Kronsteiner; Vanessa Weyer; Ti-Sun Kim; Christopher J Lux; Sinan Sen
Journal:  Dentomaxillofac Radiol       Date:  2021-07-08       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.