Influence of ionization source design on matrix effects during LC-ESI-MS/MS analysis.

Chinmoy Ghosh1, Chandrakant P Shinde, Bhaswat S Chakraborty.   

Abstract

Glycerophosphocholines (GPChos) are known to cause matrix ionization effects during the analysis of biological samples (i.e. plasma, urine, etc.) in LC-MS/MS. In general, such matrix effect is directly related to an insufficient sample clean-up of the biofluids. In addition to GPCho; design of ionization source and/or LC also plays a very important role in matrix effects. In this research paper, different types of matrix effects, i.e. ion suppression or enhancement were observed in differently designed ion sources coupled with different LCs, from the same molecule, acamprosate (ACM), under the same chromatographic conditions. ACM was analyzed in a negative polarity in electrospray ionization interface using Z-spray and orthogonal spray ion source design. The analyte showed almost complete ion suppression in the Z-spray ionization source coupled with UPLC/HPLC, whereas there was very little ion enhancement in the orthogonal spray ionization source coupled with HPLC. In both the cases different GPChos were responsible, as evident from the presence of m/z 815.4 in Z-spray ion source and m/z 759.0 in orthogonal spray ion source. Hence, this approach can be used to evaluate the matrix effects in plasma samples during development and validation of LC-MS/MS method of drugs and their metabolites in different biological matrixes.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22464433     DOI: 10.1016/j.jchromb.2012.03.012

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  7 in total

Review 1.  Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring.

Authors:  Parinya Panuwet; Ronald E Hunter; Priya E D'Souza; Xianyu Chen; Samantha A Radford; Jordan R Cohen; M Elizabeth Marder; Kostya Kartavenka; P Barry Ryan; Dana Boyd Barr
Journal:  Crit Rev Anal Chem       Date:  2016       Impact factor: 6.535

2.  Aspects of matrix and analyte effects in clinical pharmacokinetic sample analyses using LC-ESI/MS/MS - Two case examples.

Authors:  Guohua An; Thanh Bach; Inas Abdallah; Demet Nalbant
Journal:  J Pharm Biomed Anal       Date:  2020-01-30       Impact factor: 3.935

3.  Using Visualized Matrix Effects to Develop and Improve LC-MS/MS Bioanalytical Methods, Taking TRAM-34 as an Example.

Authors:  Jia-Hung Ye; Li-Heng Pao
Journal:  PLoS One       Date:  2015-04-24       Impact factor: 3.240

4.  Fast LC-ESI-MS/MS analysis and influence of sampling conditions for gut metabolites in plasma and serum.

Authors:  Tom van der Laan; Tim Kloots; Marian Beekman; Alida Kindt; Anne-Charlotte Dubbelman; Amy Harms; Cornelia M van Duijn; P Eline Slagboom; Thomas Hankemeier
Journal:  Sci Rep       Date:  2019-08-26       Impact factor: 4.379

Review 5.  Recent developments and emerging trends of mass spectrometric methods in plant hormone analysis: a review.

Authors:  Liyuan Wang; Yilin Zou; Han Yeong Kaw; Gang Wang; Huaze Sun; Long Cai; Chengyu Li; Long-Yue Meng; Donghao Li
Journal:  Plant Methods       Date:  2020-04-16       Impact factor: 4.993

Review 6.  Bioanalysis of aminoglycosides using high-performance liquid chromatography.

Authors:  Seth K Amponsah; Joseph A Boadu; Daniel K Dwamena; Kwabena F M Opuni
Journal:  ADMET DMPK       Date:  2022-02-14

7.  Simultaneous Quantification of Steroid Hormones Using hrLC-MS in Endocrine Tissues of Male Rats and Human Samples.

Authors:  Guillermo Bordanaba-Florit; Sebastiaan van Liempd; Diana Cabrera; Félix Royo; Juan Manuel Falcón-Pérez
Journal:  Metabolites       Date:  2022-07-30
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.