Literature DB >> 22460340

The appearance of dural sealants under MR imaging.

P E Tarapore1, P Mukherjee, P V Mummaneni, C P Ames.   

Abstract

Dural sealants are an adjunct to obtain watertight closure after intradural procedures. This study aims to characterize the appearance on MR imaging of 3 commonly employed dural sealants: fibrin glue, PEGH, and BSAG. To this end, patients who underwent spinal intradural procedures that included the use of dural sealant during closure were identified retrospectively. Post-operative data on 15 patients, including complications such as pseudomeningocele formation and infection, were gathered. The appearance of dural sealants on follow-up MR imaging scans within 3 days of surgery was analyzed. Fifteen patients were identified (5 with fibrin glue, 5 with PEGH, and 5 with BSAG applied during closure) with appropriately timed post-operative MR imaging scans. All 3 substances were identifiable based on anatomic location and imaging characteristics on post-operative MR imaging in standard T1, T1 PGFS, and T2 FSE. Definite differentiation between CSF and fibrin glue or PEGH was not possible with the T1 or T1 PGFS, or with the T2 FSE. Differences in intensity between CSF and BSAG were also not significant on either T1 sequence, but they were statistically significant on the T2 FSE. All patients had an uneventful post-operative course, and no patients developed post-operative pseudomeningocele at 30 days. This study concludes that water-based dural sealants such as fibrin glue and PEGH are difficult to differentiate from CSF on standard T1, T1 PGFS and T2 FSE, while BSAG is easily recognized on the T2 FSE. Recognition of water-based sealants therefore requires communication between the neurosurgeon and the neuroradiologist to avoid post-operative misidentification.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22460340      PMCID: PMC7966541          DOI: 10.3174/ajnr.A3078

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  12 in total

1.  Reconstruction of the sellar floor using Bioglue following transsphenoidal procedures.

Authors:  Arun Kumar; Nicholas F Maartens; Andrew H Kaye
Journal:  J Clin Neurosci       Date:  2003-01       Impact factor: 1.961

2.  Persistence of Bioglue in spinal dural repair.

Authors:  Tanya Yuen; Andrew H Kaye
Journal:  J Clin Neurosci       Date:  2005-01       Impact factor: 1.961

3.  The effect of autologous fibrin tissue adhesive on postoperative cerebrospinal fluid leak in spinal cord surgery: a randomized controlled trial.

Authors:  Hiroshi Nakamura; Yukihiro Matsuyama; Hisatake Yoshihara; Yoshihito Sakai; Yoshito Katayama; Shojiro Nakashima; Jyunki Takamatsu; Naoki Ishiguro
Journal:  Spine (Phila Pa 1976)       Date:  2005-07-01       Impact factor: 3.468

4.  DuraSeal magnetic resonance and computed tomography imaging: evaluation in a canine craniotomy model.

Authors:  Daniel F Kacher; Kai Frerichs; Jeffrey Pettit; Patrick K Campbell; Tim Meunch; Alexander M Norbash
Journal:  Neurosurgery       Date:  2006-02       Impact factor: 4.654

5.  Use of a novel absorbable hydrogel for augmentation of dural repair: results of a preliminary clinical study.

Authors:  Jeroen D Boogaarts; J André Grotenhuis; Ronald H M A Bartels; Tjemme Beems
Journal:  Neurosurgery       Date:  2005-07       Impact factor: 4.654

6.  Evaluation of the use of BioGlue in neurosurgical procedures.

Authors:  Arun Kumar; Nicholas F Maartens; Andrew H Kaye
Journal:  J Clin Neurosci       Date:  2003-11       Impact factor: 1.961

7.  The biocompatibility of BioGlue with the cerebral cortex: a pilot study.

Authors:  Stanley S Stylli; Arun Kumar; Michael Gonzales; Andrew H Kaye
Journal:  J Clin Neurosci       Date:  2004-08       Impact factor: 1.961

8.  Use of Tisseel fibrin sealant in neurosurgical procedures: incidence of cerebrospinal fluid leaks and cost-benefit analysis in a retrospective study.

Authors:  Amin Kassam; Michael Horowitz; Ricardo Carrau; Carl Snyderman; William Welch; Barry Hirsch; Yue Fang Chang
Journal:  Neurosurgery       Date:  2003-05       Impact factor: 4.654

9.  Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery.

Authors:  Khoi D Than; Clinton J Baird; Alessandro Olivi
Journal:  Neurosurgery       Date:  2008-07       Impact factor: 4.654

10.  Toward optimal tissue sealants for neurosurgery: use of a novel hydrogel sealant in a canine durotomy repair model.

Authors:  Mark C Preul; William D Bichard; Robert F Spetzler
Journal:  Neurosurgery       Date:  2003-11       Impact factor: 4.654

View more
  3 in total

Review 1.  Fibrin Sealant: The Only Approved Hemostat, Sealant, and Adhesive-a Laboratory and Clinical Perspective.

Authors:  William D Spotnitz
Journal:  ISRN Surg       Date:  2014-03-04

2.  Hemostasis and other benefits of fibrin sealants/glues in spine surgery beyond cerebrospinal fluid leak repairs.

Authors:  Nancy E Epstein
Journal:  Surg Neurol Int       Date:  2014-08-28

3.  The Use Fibrin Sealant after Spinal Intradural Tumor Surgery: Is It Necessary?

Authors:  Young Il Won; Chi Heon Kim; Chun Kee Chung; Tae-Ahn Jahng; Sung Bae Park
Journal:  Korean J Spine       Date:  2016-03-31
  3 in total