Literature DB >> 22455990

A breathing thorax phantom with independently programmable 6D tumour motion for dosimetric measurements in radiation therapy.

P Steidl1, D Richter, C Schuy, E Schubert, Th Haberer, M Durante, C Bert.   

Abstract

Irradiation of moving targets using a scanned ion beam can cause clinically intolerable under- and overdosages within the target volume due to the interplay effect. Several motion mitigation techniques such as gating, beam tracking and rescanning are currently investigated to overcome this restriction. To enable detailed experimental studies of potential mitigation techniques a complex thorax phantom was developed. The phantom consists of an artificial thorax with ribs to introduce density changes. The contraction of the thorax can be controlled by a stepping motor. A robotic driven detector head positioned inside the thorax mimics e.g. a lung tumour. The detector head comprises 20 ionization chambers and 5 radiographic films for target dose measurements. The phantom's breathing as well as the 6D tumour motion (3D translation, 3D rotation) can be programmed independently and adjusted online. This flexibility allows studying the dosimetric effects of correlation mismatches between internal and external motions, irregular breathing, or baseline drifts to name a few. Commercial motion detection systems, e.g. VisionRT or Anzai belt, can be mounted as they would be mounted in a patient case. They are used to control the 4D treatment delivery and to generate data for 4D dose calculation. To evaluate the phantom's properties, measurements addressing reproducibility, stability, temporal behaviour and performance of dedicated breathing manoeuvres were performed. In addition, initial dosimetric tests for treatment with a scanned carbon beam are reported.

Entities:  

Mesh:

Year:  2012        PMID: 22455990     DOI: 10.1088/0031-9155/57/8/2235

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  An externally and internally deformable, programmable lung motion phantom.

Authors:  Yam Cheung; Amit Sawant
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

2.  Development of a 6DOF robotic motion phantom for radiation therapy.

Authors:  Andrew H Belcher; Xinmin Liu; Zachary Grelewicz; Erik Pearson; Rodney D Wiersma
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

Review 3.  Particle therapy of moving targets-the strategies for tumour motion monitoring and moving targets irradiation.

Authors:  Tomasz Kubiak
Journal:  Br J Radiol       Date:  2016-07-19       Impact factor: 3.039

Review 4.  Advances in 4D treatment planning for scanned particle beam therapy - report of dedicated workshops.

Authors:  Christoph Bert; Christian Graeff; Marco Riboldi; Simeon Nill; Guido Baroni; Antje-Christin Knopf
Journal:  Technol Cancer Res Treat       Date:  2013-12-17

5.  Commissioning of an integrated platform for time-resolved treatment delivery in scanned ion beam therapy by means of optical motion monitoring.

Authors:  G Fattori; N Saito; M Seregni; R Kaderka; A Pella; A Constantinescu; M Riboldi; P Steidl; P Cerveri; C Bert; M Durante; G Baroni
Journal:  Technol Cancer Res Treat       Date:  2013-12-17

6.  Feasibility Study on Cardiac Arrhythmia Ablation Using High-Energy Heavy Ion Beams.

Authors:  H Immo Lehmann; Christian Graeff; Palma Simoniello; Anna Constantinescu; Mitsuru Takami; Patrick Lugenbiel; Daniel Richter; Anna Eichhorn; Matthias Prall; Robert Kaderka; Fine Fiedler; Stephan Helmbrecht; Claudia Fournier; Nadine Erbeldinger; Ann-Kathrin Rahm; Rasmus Rivinius; Dierk Thomas; Hugo A Katus; Susan B Johnson; Kay D Parker; Jürgen Debus; Samuel J Asirvatham; Christoph Bert; Marco Durante; Douglas L Packer
Journal:  Sci Rep       Date:  2016-12-20       Impact factor: 4.379

7.  A transit portal dosimetry method for respiratory gating quality assurance with a dynamic 3D printed tumor phantom.

Authors:  Hong Qi Tan; Calvin Wei Yang Koh; Lloyd Kuan Rui Tan; Kah Seng Lew; Clifford Ghee Ann Chua; Khong Wei Ang; James Cheow Lei Lee; Sung Yong Park
Journal:  J Appl Clin Med Phys       Date:  2022-02-11       Impact factor: 2.243

Review 8.  Management of organ motion in scanned ion beam therapy.

Authors:  Christoph Bert; Klaus Herfarth
Journal:  Radiat Oncol       Date:  2017-11-06       Impact factor: 3.481

9.  A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy.

Authors:  Takehiro Shiinoki; Fumitake Fujii; Koya Fujimoto; Yuki Yuasa; Tatsuhiro Sera
Journal:  J Appl Clin Med Phys       Date:  2020-04-13       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.