Literature DB >> 2245562

Hydroxyapatite-coated total hip prostheses. Two-year clinical and roentgenographic results of 100 cases.

R G Geesink1.   

Abstract

Studies of implant fixation have shown that hydroxyapatite (HA) coatings provide early and strong fixation to bone. This is a report of 100 consecutive cases of total hip arthroplasties, using HA coating, which were mainly for osteoarthrosis, avascular necrosis, or revision for failed implants. The average prospective follow-up period was two years. Titanium femoral components had a proximal HA coating, usually with an HA-coated screw cup. For both HA-coated components, the average Harris hip score was 96 points after one year and 98 after two years. Analysis of data shows that the incidence of pain was low immediately after surgery and at 4% one year postoperatively. There was no difference between the results of primary cases and revisions after the one-year interval. On roentgenographic examination, there was a rapid bony integration of implants with bone apposition on the coating within six months, accompanied by specific patterns of remodeling. No radiolucent line formation was detected around HA-coated implant parts. There were no revisions for loose implants. After two years, 97% of the patients had positive roentgenographic evidence of femoral ingrowth compared to 55% for HA-coated acetabular cups, with a statistical significance between bone ingrowth and clinical results. Implant fixation using HA coatings is a reliable procedure for good bony fixation and clinical results.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2245562

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Osseointegration in hip prostheses: experimental study in sheep.

Authors:  C Doria; V De Santis; G Falcone; L Proietti; E De Santis
Journal:  Int Orthop       Date:  2003-06-17       Impact factor: 3.075

2.  Topographical characterization and microstructural interface analysis of vacuum-plasma-sprayed titanium and hydroxyapatite coatings on carbon fibre-reinforced poly(etheretherketone).

Authors:  S W Ha; A Gisep; J Mayer; E Wintermantel; H Gruner; M Wieland
Journal:  J Mater Sci Mater Med       Date:  1997-12       Impact factor: 3.896

3.  X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants.

Authors:  L Savarino; S Stea; D Granchi; M E Donati; M Cervellati; A Moroni; G Paganetto; A Pizzoferrato
Journal:  J Mater Sci Mater Med       Date:  1998-02       Impact factor: 3.896

4.  Osteogenic protein-1 delivered by hydroxyapatite-coated implants improves bone ingrowth in extracortical bone bridging.

Authors:  Neil Saran; Renwen Zhang; Robert E Turcotte
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

5.  Biocompatibility of hydroxyapatite-coated hip prostheses.

Authors:  S Santavirta; D Nordström; P Ylinen; Y T Konttinen; T Silvennoinen; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

6.  The effect of hydroxyapatite coating on the fixation of hip prostheses. A comparison of clinical and radiographic results of hip replacement in a matched-pair study.

Authors:  J Huracek; P Spirig
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

7.  Effects of total hip replacement on quality of life in patients with osteoarthritis and in patients with rheumatoid arthritis.

Authors:  M Borstlap; J L Zant; M Van Soesbergen; J K Van der Korst
Journal:  Clin Rheumatol       Date:  1994-03       Impact factor: 2.980

8.  Calcium phosphate coating formed in infusion fluid mixture to enhance fixation strength of titanium screws.

Authors:  Hirotaka Mutsuzaki; Atsuo Ito; Masataka Sakane; Yu Sogo; Ayako Oyane; Yuko Ebihara; Noboru Ichinose; Naoyuki Ochiai
Journal:  J Mater Sci Mater Med       Date:  2007-05-05       Impact factor: 3.896

9.  Surface activation of polyetheretherketone (PEEK) and formation of calcium phosphate coatings by precipitation.

Authors:  S W Ha; M Kirch; F Birchler; K L Eckert; J Mayer; E Wintermantel; C Sittig; I Pfund-Klingenfuss; M Textor; N D Spencer; M Guecheva; H Vonmont
Journal:  J Mater Sci Mater Med       Date:  1997-11       Impact factor: 3.896

10.  Effect of hydrolysis on the phase evolution of water-based sol-gel hydroxyapatite and its application to bioactive coatings.

Authors:  D-M Liu; T Troczynski; D Hakimi
Journal:  J Mater Sci Mater Med       Date:  2002-07       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.