Literature DB >> 22450111

TAVI for pure aortic valve insufficiency in a patient with a left ventricular assist device.

Giuseppe D'Ancona1, Miralem Pasic, Semih Buz, Thorsten Drews, Stephan Dreysse, Roland Hetzer, Axel Unbehaun.   

Abstract

We report transcatheter aortic valve implantation (TAVI) for pure aortic valve insufficiency in a patient with an otherwise normal aortic valve and a long-term left ventricular assist device (LVAD). An oversized 29-mm Edwards SAPIEN valve (Edwards Lifesciences, Irvine, CA) was implanted in the 21-mm native aortic valve annulus. Despite the complete absence of aortic calcifications, the prosthesis remained stably anchored inside the annulus. The reported experience demonstrates that TAVI is feasible even in patients with pure aortic valve regurgitation and can be a reasonable option in patients with aortic regurgitation after LVAD implantation.
Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22450111     DOI: 10.1016/j.athoracsur.2011.11.019

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  15 in total

Review 1.  Simultaneous procedures during left ventricular assist device implantation: is less always more?

Authors:  Nikhil Jaik; Robert S D Higgins; Bryan A Whitson
Journal:  Curr Heart Fail Rep       Date:  2014-03

Review 2.  Management of aortic insufficiency in the continuous flow left ventricular assist device population.

Authors:  Jonathan Holtz; Jeffrey Teuteberg
Journal:  Curr Heart Fail Rep       Date:  2014-03

Review 3.  [Ventricular long-term support with implantable continuous flow pumps: on the way to a gold standard in the therapy of terminal heart failure].

Authors:  T Krabatsch; E Potapov; S Soltani; M Dandel; V Falk; C Knosalla
Journal:  Herz       Date:  2015-04       Impact factor: 1.443

Review 4.  Transcatheter aortic valve replacement in patients with severe aortic stenosis and heart failure.

Authors:  Chirag Bavishi; Dhaval Kolte; Paul C Gordon; J Dawn Abbott
Journal:  Heart Fail Rev       Date:  2018-11       Impact factor: 4.214

Review 5.  Impact of adverse events on ventricular assist device outcomes.

Authors:  Aleksandar Adzic; Snehal R Patel; Simon Maybaum
Journal:  Curr Heart Fail Rep       Date:  2013-03

Review 6.  Transcatheter aortic valve implantation (TAVI) in patients with aortic regurgitation.

Authors:  Matthias Thielmann; Konstantinos Tsagakis; Mohamad El Gabry; Heinz Jakob; Daniel Wendt
Journal:  Ann Cardiothorac Surg       Date:  2017-09

7.  Medical management of patients with continuous-flow left ventricular assist devices.

Authors:  Adam D Devore; Robert J Mentz; Chetan B Patel
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-02

Review 8.  Clinical management for complications related to implantable LVAD use.

Authors:  Koichi Toda; Yoshiki Sawa
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-11-05

Review 9.  Percutaneous Transcatheter Therapies for the Management of Left Ventricular Assist Device Complications.

Authors:  Rohan J Kalathiya; Jonathan Grinstein; Nir Uriel; Atman P Shah
Journal:  J Invasive Cardiol       Date:  2017-02-15       Impact factor: 2.022

10.  Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation.

Authors:  Roberto Spina; Chris Anthony; David Wm Muller; David Roy
Journal:  Interv Cardiol       Date:  2015-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.