Literature DB >> 22449633

Evaluation of appropriate use of transthoracic echocardiography in 1,820 consecutive patients using the 2011 revised appropriate use criteria for echocardiography.

Harshal R Patil1, Tina R Coggins, Lisa L Kusnetzky, Michael L Main.   

Abstract

Revised Appropriate Use Criteria (AUC) for Echocardiography were published in 2011 and classify potential procedure indications as appropriate (score of 7 to 9), uncertain (score of 4 to 6), or inappropriate (score of 1 to 3). The appropriate utilization rate of transthoracic echocardiography in clinical practice using the revised AUC is unknown. The aim of the present study was to determine the appropriate utilization rate of echocardiography in a large number of consecutive studies in clinical practice and to determine the number of "unclassifiable" studies using the revised and expanded AUC. The clinical indication for transthoracic echocardiography (TTE) was determined on the basis of a detailed review of preprocedural clinical documentation. These clinical indications were further classified (when possible) into 1 of the 98 indications described in the 2011 AUC for echocardiography. From December 2010 to January 2011, 1,825 patients (mean age 63.2 years) underwent TTE for clinical reasons. Of the final study group of 1,820 patients, TTE was appropriate in 82%, inappropriate in 12.3%, and uncertain in 5.3%, and 0.4% studies were unclassifiable. The evaluation of symptoms potentially due to a cardiac etiology was the most common appropriate indication for TTE (27.5%). The most common inappropriate indication was routine surveillance (<1 year) of heart failure without a change in clinical status (2.5%). In conclusion, most TTE studies were appropriately ordered, and only a very small number of studies were unclassifiable.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22449633     DOI: 10.1016/j.amjcard.2012.02.025

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

1.  A systematic review of Appropriate Use Criteria for transthoracic echocardiography: are they relevant outside the United States?

Authors:  Robert N Kerley; Siun O'Flynn
Journal:  Ir J Med Sci       Date:  2018-06-18       Impact factor: 1.568

2.  Utilisation of echocardiography and application of the appropriate use criteria at a large tertiary hospital in Queensland.

Authors:  Anthony De Nardo; Selvanayagam Niranjan
Journal:  Australas J Ultrasound Med       Date:  2016-05-20

3.  Diagnostic Yield of Outpatient Pediatric Echocardiograms: Impact of Indications and Specialty.

Authors:  Sean M Lang; Elijah Bolin; Sarah Hardy; Xinyu Tang; R Thomas Collins
Journal:  Pediatr Cardiol       Date:  2016-11-08       Impact factor: 1.655

4.  Limitations of free-form-text diagnostic requisitions as a tool for evaluating adherence to appropriate use criteria for transthoracic echocardiography.

Authors:  Behnam Banihashemi; Kasra Maftoon; Benjamin J W Chow; Jordan Bernick; George A Wells; Ian G Burwash
Journal:  Cardiovasc Ultrasound       Date:  2015-01-15       Impact factor: 2.062

5.  An assessment of the clinical utility of echocardiography criteria in a Tertiary Health Center.

Authors:  Ehimwenma J Ogbemudia; Wilson E Sadoh
Journal:  Niger Med J       Date:  2015 Jul-Aug

6.  Appropriate Use Criteria in Echocardiography: An Observational Institutional Study with the Perspective of a Quality Improvement Project.

Authors:  Vanessa Rameh; Antoine Kossaify
Journal:  Clin Med Insights Cardiol       Date:  2016-02-16

7.  Appropriate use criteria for echocardiography in the Netherlands.

Authors:  B J Bouma; R Riezenbos; A J Voogel; M H Veldhorst; W Jaarsma; J Hrudova; B Cernohorsky; S Chamuleau; R B A van den Brink; R Breedveld; C Reichert; O Kamp; R Braam; J P van Melle
Journal:  Neth Heart J       Date:  2017-05       Impact factor: 2.380

Review 8.  Echocardiography practice: insights into appropriate clinical use, technical competence and quality improvement program.

Authors:  Antoine Kossaify; Gilles Grollier
Journal:  Clin Med Insights Cardiol       Date:  2014-01-02

9.  How I do it: judging appropriateness for TTE and TEE.

Authors:  Ricardo Fonseca; Thomas H Marwick
Journal:  Cardiovasc Ultrasound       Date:  2014-06-24       Impact factor: 2.062

10.  Impact of a structured referral algorithm on the ability to monitor adherence to appropriate use criteria for transthoracic echocardiography.

Authors:  Steven Promislow; Joseph G Abunassar; Behnam Banihashemi; Benjamin J Chow; Girish Dwivedi; Kasra Maftoon; Ian G Burwash
Journal:  Cardiovasc Ultrasound       Date:  2016-08-15       Impact factor: 2.062

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.