Osseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.

Oliver Hoffmann1, Nikola Angelov, Gregory-George Zafiropoulos, Sebastiano Andreana.   

Abstract

PURPOSE: Zirconia ceramics are a viable alternative to titanium for use as dental implants. However, the smooth surface of zirconia means that longer healing periods are needed to accomplish osseointegration compared to roughened titanium surfaces. Surface modifications can be used to increase the roughness of zirconia. The aim of this study was to assess histologically and compare the degree of early bone apposition around zirconia dental implants with sandblasted, sintered, or laser-modified surfaces to that seen around surface-modified titanium implants. Removal torque was also measured and compared.
MATERIALS AND METHODS: Ninety-six implants--24 each of four types (sintered zirconia, laser-modified zirconia, sandblasted zirconia, and acid-etched titanium)--were placed in 48 New Zealand White female rabbits. One implant was inserted in each distal femur. Half of the specimens were harvested at 6 or 12 weeks and processed for light microscopic analysis; the area of bone-to-implant contact was measured morphometrically. The other half were evaluated for removal torque at 6 and 12 weeks.
RESULTS: No statistically significant differences existed in bone apposition between the different surfaces at either time point. Differences in removal torque were significantly different between titanium and sandblasted zirconia and between sintered zirconia and sandblasted zirconia, with the first mentioned demonstrating a higher torque value at 6 weeks. At 12 weeks, the only significant difference in removal torque was between titanium and sandblasted zirconia, with titanium demonstrating the higher value.
CONCLUSION: Comparable rates of bone apposition in the zirconia and titanium implant surfaces at 6 and 12 weeks of healing were observed. Removal torque values were similar for all implants with a roughened surface.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22442775

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

Authors:  Merve Goymen; Eren Isman; Lale Taner; Mehmet Kurkcu
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

Review 2.  Zirconia surface modifications for implant dentistry.

Authors:  Fernanda H Schünemann; María E Galárraga-Vinueza; Ricardo Magini; Márcio Fredel; Filipe Silva; Júlio C M Souza; Yu Zhang; Bruno Henriques
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-16       Impact factor: 7.328

3.  Bone tissue response to experimental zirconia implants.

Authors:  Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2016-08-09       Impact factor: 3.573

Review 4.  Effect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis.

Authors:  Ali Hafezeqoran; Roodabeh Koodaryan
Journal:  Biomed Res Int       Date:  2017-02-16       Impact factor: 3.411

5.  Biological and osseointegration capabilities of hierarchically (meso-/micro-/nano-scale) roughened zirconia.

Authors:  Naser Mohammadzadeh Rezaei; Masakazu Hasegawa; Manabu Ishijima; Kourosh Nakhaei; Takahisa Okubo; Takashi Taniyama; Amirreza Ghassemi; Tania Tahsili; Wonhee Park; Makoto Hirota; Takahiro Ogawa
Journal:  Int J Nanomedicine       Date:  2018-06-08

Review 6.  Advancing dental implants: Bioactive and therapeutic modifications of zirconia.

Authors:  Divya Chopra; Anjana Jayasree; Tianqi Guo; Karan Gulati; Sašo Ivanovski
Journal:  Bioact Mater       Date:  2021-11-05

7.  German S3 guideline on the use of dental ceramic implants.

Authors:  D G E Thiem; D Stephan; K Kniha; R J Kohal; S Röhling; C B Spies; M Stimmelmayr; K A Grötz
Journal:  Int J Implant Dent       Date:  2022-10-03

Review 8.  Zirconia in dental implantology: A review.

Authors:  Abhishek Apratim; Prashanti Eachempati; Kiran Kumar Krishnappa Salian; Vijendra Singh; Saurabh Chhabra; Sanket Shah
Journal:  J Int Soc Prev Community Dent       Date:  2015 May-Jun

9.  Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration.

Authors:  Romain Vayron; Vu-Hieu Nguyen; Benoît Lecuelle; Hugues Albini Lomami; Jean-Paul Meningaud; Romain Bosc; Guillaume Haiat
Journal:  Sensors (Basel)       Date:  2018-05-02       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.