Literature DB >> 22440159

Eye injury risk from water stream impact: biomechanically based design parameters for water toy and park design.

Stefan M Duma1, Jill A Bisplinghoff, Danielle M Senge, Craig McNally, Vanessa D Alphonse.   

Abstract

PURPOSE: Interactive water displays are becoming increasingly popular and can result in direct eye contact. Therefore, the purpose of this study is to investigate eye injury risk from high speed water stream impacts and to provide biomechanically based design parameters for water toys and water park fountains.
METHODS: An experimental matrix of 38 tests was developed to impact eight porcine eyes with water streams using a customized pressure system. Two stream diameters (3.2 mm and 6.4 mm) were tested at water velocities between 3.0 m/s and 8.5 m/s. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve and used to determine the injury risk for hyphema, lens dislocation, retinal damage, and globe rupture for each impact.
RESULTS: Experimental water stream impacts created a range of intraocular pressures between 3156 mmHg and 7006 mmHg (61 psi to 135 psi). Injury risk varied between 4.4%-27.8% for hyphema, 0.0%-3.0% for lens dislocation, and 0.1%-3.3% for retinal damage. All tests resulted in 0.0% injury risk for globe rupture. The two water stream diameters did not result in significantly different water stream velocities (P = 0.32); however, the variation in water stream diameter did result in significantly different intraocular pressures (P = 0.03) with higher pressures for the 6.4 mm stream.
CONCLUSIONS: This is the first study to experimentally measure intraocular pressure from high speed water stream impacts and quantify the corresponding eye injury risk. It is recommended that toy water guns and water park fountains use an upper threshold of 8.5 m/s for water stream velocities to minimize the risk of serious acute eye damage from impacts.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22440159     DOI: 10.3109/02713683.2011.626911

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  3 in total

Review 1.  [Medical aspects of common non-lethal weapons].

Authors:  Sebastian Niko Kunz; Christina Grove; Fabio Monticelli
Journal:  Wien Med Wochenschr       Date:  2013-11-20

2.  In vivo evaluation of the cornea and conjunctiva of the normal laboratory beagle using time- and Fourier-domain optical coherence tomography and ultrasound pachymetry.

Authors:  Ann R Strom; Dennis E Cortés; Carol A Rasmussen; Sara M Thomasy; Kim McIntyre; Shwu-Fei Lee; Philip H Kass; Mark J Mannis; Christopher J Murphy
Journal:  Vet Ophthalmol       Date:  2015-02-10       Impact factor: 1.644

3.  Exogenous endophthalmitis caused by Enterococcus casseliflavus: A case report and discussion regarding treatment of intraocular infection with vancomycin-resistant enterococci.

Authors:  Byron M Berenger; Shobhana Kulkarni; Brad J Hinz; Sarah E Forgie
Journal:  Can J Infect Dis Med Microbiol       Date:  2015 Nov-Dec       Impact factor: 2.471

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.