Literature DB >> 22438683

Evaluation of ultra-low dose CT in the diagnosis of pediatric-like fractures using an experimental animal study.

Joerg D Moritz1, Beata Hoffmann, Dirk Sehr, Katrin Keil, Juliane Eggerking, Godo Groth, Amke Caliebe, Jens Dischinger, Martin Heller, Hendrik Bolte.   

Abstract

OBJECTIVE: The aim of this prospective study was to evaluate the performance of ultra-low dose CT for the diagnosis of pediatric-like fractures and ascertain the lowest dose level sufficient for diagnostics.
MATERIALS AND METHODS: Fifty-one bones of young pig cadavers were artificially fractured and subsequently examined by using a 64 multi-detector CT with 36 various dose levels down to a dose comparable with that of X-rays. Two pediatric radiologists analysed the CT scans according to the presence or absence of a fracture, determination of the fracture type and the displacement as well as the diagnostic certainty. For each dose protocol, a success rate for the correct determination of the above-mentioned CT analyses was calculated. A success rate of at least 95% was considered sufficient for diagnostics.
RESULTS: All but the lowest dose levels were sufficient to identify the fracture. Only the two lowest dose levels were insufficient to detect the fracture type. All dose levels were adequate for the identification of the displacement. The lowest dose level sufficient for diagnostics was 120 kVp, 11 mAs, and pitch 1.5, with a CTDIvol of 10% of a standard dose and an effective dose three times as large as that of X-rays.
CONCLUSION: Ultra-low dose CT provides the feasibility of a significant dose reduction, still allowing sufficient diagnostics of pediatric-like fractures.

Entities:  

Keywords:  Experimental study; Fractures in children; Skeletal-appendicular; Ultra-low dose CT

Mesh:

Year:  2012        PMID: 22438683      PMCID: PMC3303899          DOI: 10.3348/kjr.2012.13.2.165

Source DB:  PubMed          Journal:  Korean J Radiol        ISSN: 1229-6929            Impact factor:   3.500


  20 in total

1.  Does ultra-low-dose CT with a radiation dose equivalent to that of KUB suffice to detect renal and ureteral calculi?

Authors:  Claudia Kluner; Patrick A Hein; Oliver Gralla; Eike Hein; Bernd Hamm; Valentina Romano; Patrik Rogalla
Journal:  J Comput Assist Tomogr       Date:  2006 Jan-Feb       Impact factor: 1.826

2.  Patient radiation doses from adult and pediatric CT.

Authors:  Walter Huda; Awais Vance
Journal:  AJR Am J Roentgenol       Date:  2007-02       Impact factor: 3.959

3.  Can low-dose computed tomographic scan of the spine replace conventional radiography? An evaluation based on imaging myelomas, bone metastases, and fractures from osteoporosis.

Authors:  Madleen Chassang; Anne Grimaud; J M Cucchi; Sébastien Novellas; Nicolas Amoretti; Patrick Chevallier; Jean Noël Bruneton
Journal:  Clin Imaging       Date:  2007 Jul-Aug       Impact factor: 1.605

4.  Detection of simulated inflicted metaphyseal fractures in a fetal pig model: image optimization and dose reduction with computed radiography.

Authors:  Patricia L Kleinman; David Zurakowski; Keith J Strauss; Robert H Cleveland; Jeannette M Perez-Rosello; David P Nichols; Kelly H Zou; Paul K Kleinman
Journal:  Radiology       Date:  2008-05       Impact factor: 11.105

5.  Ultrasound in diagnosis of fractures in children: unnecessary harassment or useful addition to X-ray?

Authors:  J D Moritz; L D Berthold; S F Soenksen; G F Alzen
Journal:  Ultraschall Med       Date:  2008-06       Impact factor: 6.548

6.  Multidetector CT in patients suspected of having lumbar disk herniation: comparison of standard-dose and simulated low-dose techniques.

Authors:  Pascale Bohy; Viviane de Maertelaer; Aymeric Roquigny; Caroline Keyzer; Denis Tack; Pierre Alain Gevenois
Journal:  Radiology       Date:  2007-08       Impact factor: 11.105

7.  Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma.

Authors:  T H Mulkens; P Marchal; S Daineffe; R Salgado; P Bellinck; B te Rijdt; B Kegelaers; J-L Termote
Journal:  AJNR Am J Neuroradiol       Date:  2007-09       Impact factor: 3.825

8.  Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

Authors:  T G Gleeson; J Moriarty; C P Shortt; J P Gleeson; P Fitzpatrick; B Byrne; J McHugh; M O'Connell; P O'Gorman; S J Eustace
Journal:  Skeletal Radiol       Date:  2008-11-14       Impact factor: 2.199

9.  Delineation of temporal bone anatomy: feasibility of low-dose 64-row CT in regard to image quality.

Authors:  Jürgen Lutz; Vanessa Jäger; Martin John Hempel; Sudesh Srivastav; Maximilian Reiser; Lorenz Jäger
Journal:  Eur Radiol       Date:  2007-03-07       Impact factor: 7.034

10.  Ultrasound diagnosis of either an occult or missed fracture of an extremity in pediatric-aged children.

Authors:  Kil-Ho Cho; Sung-Moon Lee; Young-Hwan Lee; Kyung-Jin Suh
Journal:  Korean J Radiol       Date:  2009-12-28       Impact factor: 3.500

View more
  5 in total

1.  Radiation dose reduction in multidetector CT in fracture evaluation.

Authors:  Jung Woo Yi; Hee Jin Park; So Yeon Lee; Myung Ho Rho; Hyun Pyo Hong; Yoon Jung Choi; Mi Sung Kim
Journal:  Br J Radiol       Date:  2017-07-14       Impact factor: 3.039

Review 2.  New and emerging patient-centered CT imaging and image-guided treatment paradigms for maxillofacial trauma.

Authors:  David Dreizin; Arthur J Nam; Jeffrey Hirsch; Mark P Bernstein
Journal:  Emerg Radiol       Date:  2018-06-20

3.  Usefulness of low dose chest CT for initial evaluation of blunt chest trauma.

Authors:  Sung Jung Kim; Anjali Basnyat Bista; Young Gi Min; Eun Young Kim; Kyung Joo Park; Doo Kyoung Kang; Joo Sung Sun
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

4.  Multidetector computed tomography for the assessment of adnexal mass: is unenhanced CT scan necessary?

Authors:  Sung Il Jung; Hee Sun Park; Young Jun Kim; Hae Jeong Jeon
Journal:  Korean J Radiol       Date:  2014-01-08       Impact factor: 3.500

5.  Radiation dose reduction via sinogram affirmed iterative reconstruction and automatic tube voltage modulation (CARE kV) in abdominal CT.

Authors:  Hyun Joo Shin; Yong Eun Chung; Young Han Lee; Jin-Young Choi; Mi-Suk Park; Myeong-Jin Kim; Ki Whang Kim
Journal:  Korean J Radiol       Date:  2013-11-05       Impact factor: 3.500

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.